从自然语音声音中早期检测高血压,使用图形扩散网络
Haydar Ankışhan1, Haydar Celik2, Haluk Ulucanlar3
1Stem Cell Institute, Ankara University, Ankara, Turkey.
Computers in biology and medicine
|December 24, 2024
概括
这项研究引入了一种使用语音和人口统计数据的无袖血压预测方法. 图形扩散网络 (GDN) 模型显示了早期高血压检测的高准确性,提供了一个非侵入性监测解决方案.
科学领域:
- 生物医学工程 生物医学工程
- 信号处理 信号处理
- 心血管健康 心血管健康
背景情况:
- 传统的血压监测需要手,限制了连续和远程评估.
- 非侵入性方法对于广泛的查和管理至关重要,特别是在服务不足的地区.
研究的目的:
- 开发和验证使用语音和人口特征的无袖血压预测模型.
- 评估模型在检测早期高血压的有效性.
主要方法:
- 利用图形扩散网络 (GDN) 模型整合语音信号和人口统计数据.
- 使用R平方 (R2) 和皮尔森相关系数 (PCC) 评估模型性能.
- 使用F1-Score和准确度指标评估了早期高血压检测.
主要成果:
- 在结合语音和人口特征时,GDN模型实现了0.96的R2和0.98的PCC.
- 对于早期高血压检测,该模型的F1-Score为0.8735±0.10,准确度为0.8896±0.11.
- 仅仅语音特征就产生了0.740的R2和0.764的PCC,证明了人口统计数据的附加值.
结论:
- 结合语音和人口特征,显著提高了无袖血压预测的准确性.
- 开发的模型显示出非侵入性,远程血压监测和早期高血压检测的巨大潜力.
更多相关视频
相关概念视频
Special considerations while measuring blood pressure
703
When assessing blood pressure (BP), healthcare professionals must consider various factors and potential unexpected outcomes to ensure accurate readings and provide proper patient care. Adhering to these guidelines is essential to achieving the most reliable results.
Monitoring Both Arms:
Monitoring BP in both arms during the initial assessment is advisable, as the systolic value may differ by five to ten mm Hg between arms. For subsequent BP assessments, use the arm with the higher reading.
Monitoring Both Arms:
Monitoring BP in both arms during the initial assessment is advisable, as the systolic value may differ by five to ten mm Hg between arms. For subsequent BP assessments, use the arm with the higher reading.
703
Measurement of Blood Pressure
868
Assessing blood pressure is a standard procedure executed in virtually all medical environments. The method utilized today was established over a hundred years ago by an innovative Russian doctor, Dr. Nikolai Korotkoff. The soft ticking noise, known as Korotkoff sounds, heard while taking blood pressure readings results from turbulent blood flow within the vessels. The apparatus required for this procedure includes a sphygmomanometer, a blood pressure cuff attached to a gauge, and a...
868
Pre-Procedural Guidelines for Assessing Blood Pressure
520
Accurate blood pressure assessment is crucial for diagnosing and managing various health conditions. To ensure the reliability of these measurements, healthcare professionals must adhere to standardized pre-procedural guidelines. These guidelines enhance patient safety and improve the overall quality of healthcare. The following steps are essential for obtaining accurate and consistent blood pressure readings, from using the appropriate tools to ensuring effective communication with the...
520
Equipments Used To Measure Blood Pressure
825
Direct Method
This invasive approach involves cannulating a peripheral artery. During each cardiac contraction, pressure generates mechanical motion within the catheter, transmitted through rigid, fluid-filled tubing to a transducer. This transducer converts mechanical motion into electrical signals displayed as waveforms on a monitor. An automatic flushing system prevents blood backflow. Due to the potential risk of unexpected arterial blood loss, this method is primarily used in intensive...
This invasive approach involves cannulating a peripheral artery. During each cardiac contraction, pressure generates mechanical motion within the catheter, transmitted through rigid, fluid-filled tubing to a transducer. This transducer converts mechanical motion into electrical signals displayed as waveforms on a monitor. An automatic flushing system prevents blood backflow. Due to the potential risk of unexpected arterial blood loss, this method is primarily used in intensive...
825
Assessing Blood pressure using a doppler ultrasound
1.2K
To obtain accurate blood pressure measurements in clinical settings, especially when traditional methods are insufficient, healthcare professionals utilize the Doppler ultrasound technique. This method uses high-frequency sound waves to detect blood flow within the arteries, which is crucial for patients with conditions that complicate circulatory system assessment.
Pre-Procedural Guidelines for Doppler Ultrasound Blood Pressure Assessment:
Preparation of Equipment:
Pre-Procedural Guidelines for Doppler Ultrasound Blood Pressure Assessment:
Preparation of Equipment:
1.2K
Korotkoff Sounds
2.9K
Korotkoff sounds are the specific sounds heard while measuring blood pressure using a sphygmomanometer, typically with a stethoscope or a Doppler device. They are named after Russian physician Nikolai Korotkov, who first described them in 1905. These sounds correspond to turbulent blood flow in the artery as the blood pressure cuff is gradually released after inflation.
During blood pressure assessment, inflating the cuff 30 millimeters of mercury above the patient's systolic blood pressure...
During blood pressure assessment, inflating the cuff 30 millimeters of mercury above the patient's systolic blood pressure...
2.9K