触摸授权:用于温度映射的自持式电子纹身热电系统
M A S Almeida1, A L Pires1, J L Ramirez2
1IFIMUP Physics for Advanced Materials, Nanotechnology and Photonics, Department of Physics and Astronomy, Faculty of Sciences, University of Porto, Rua do Campo Alegre, Porto, 4169-007, Portugal.
Advanced science (Weinheim, Baden-Wurttemberg, Germany)
|December 26, 2024
概括
这项研究引入了一种新的电子纹身 (e-tattoo) 热电传感器,用于详细绘制皮肤温度图. 这种可穿戴技术可实现精确,非侵入性监测,用于早期发现疾病和主动健康管理.
科学领域:
- 可穿戴的健康技术
- 生物医学传感传感器
- 热电材料 热电材料
背景情况:
- 物联网 (IoT) 推动了医疗保健感应技术的进步.
- 可穿戴电子设备,如电子纹身 (e-tattoos),提供精确的生理监测.
- 皮肤温度是炎症,感染和慢性疾病的关键指标.
研究的目的:
- 开发和演示热电传感器电子纹身,用于详细绘制皮肤温度图.
- 利用新材料和印刷技术,实现灵活高效的热电传感.
- 探索电子纹身在非侵入性健康诊断中的潜力.
主要方法:
- 在p型Bi0.35Sb1.65Te3和n型Bi2Te2.8Se0.2薄膜上进行丝网印刷.
- 聚乙醇 (PVA) 的整合,以提高热电和柔性性能.
- 一种原型热电装置在临时纹身纸上应用,并通过数值模拟进行验证.
主要成果:
- 在临时纹身纸上展示了一种开创性的印制热电装置.
- 通过热电条纹检测温度变化,以进行详细的皮肤映射.
- 通过数值模拟来验证设备的潜力.
结论:
- 热电传感器e-tattoo显示出作为持续温度监测的非侵入性工具的巨大潜力.
- 这项技术推进了可穿戴健康诊断,用于早期检测和管理健康状况.
- 开发的电子纹身代表了可穿戴健康技术的新方法.
相关概念视频
Equipments Used to Measure Body Temperature
960
Body temperature can be assessed using various devices and measured in Celsius or Fahrenheit.
Glass-bulb Thermometer:
Glass-bulb thermometers are hollow glass tubes with a bulb tip containing liquid such as ethanol or mercury. Historically, glass bulb mercury thermometers were the standard device to measure body temperature. Today, mercury thermometers are prohibited in many countries due to the hazardous effects of mercury and the risk of exposure if the glass bulb breaks. In general,...
Glass-bulb Thermometer:
Glass-bulb thermometers are hollow glass tubes with a bulb tip containing liquid such as ethanol or mercury. Historically, glass bulb mercury thermometers were the standard device to measure body temperature. Today, mercury thermometers are prohibited in many countries due to the hazardous effects of mercury and the risk of exposure if the glass bulb breaks. In general,...
960
Temperature Measurement Sites
1.5K
A thermometer measures body temperature. The common sites for measuring body temperature are the oral cavity, axillary region, temporal artery, and skin surface, such as the forehead, abdomen, and axilla. True core body temperature is assessed in the rectum, tympanic membrane, pulmonary artery, esophagus, and urinary bladder.
Oral: When assessing oral temperature, the thermometer tip should be placed under the tongue in the posterior sublingual pocket. It offers accurate readings and can be...
Oral: When assessing oral temperature, the thermometer tip should be placed under the tongue in the posterior sublingual pocket. It offers accurate readings and can be...
1.5K
Assessing Body Temperature - Temporal Artery
521
Here is a stepwise guide to assessing the body temperature at the temporal artery using a temporal artery thermometer
Step 1: Perform hand hygiene and don a fresh pair of gloves to prevent cross-infection and ensure patient safety.
Step 2: Explain the procedure to the patient to establish trust. Clear communication establishes trust with the patient, ensures they understand what to expect, promotes cooperation, and enhances comfort during the procedure.
Step 3: Assess the patient's...
Step 1: Perform hand hygiene and don a fresh pair of gloves to prevent cross-infection and ensure patient safety.
Step 2: Explain the procedure to the patient to establish trust. Clear communication establishes trust with the patient, ensures they understand what to expect, promotes cooperation, and enhances comfort during the procedure.
Step 3: Assess the patient's...
521
Assessing Body Temperature - Oral
726
Here are the steps to accurately measure oral temperature using an electronic thermometer:
Step 1:
Start by practicing proper hand hygiene to prevent the spread of microorganisms.
Step 2:
Take the thermometer out of the charging unit, switch it on, and wait for the ready sign.
Step 3:
Gently slide the probe cover until a click is heard. This simple action prevents cross-contamination and ensures the correct placement of the probe cover.
Step 4:
Instruct the patient to open their mouth and place...
Step 1:
Start by practicing proper hand hygiene to prevent the spread of microorganisms.
Step 2:
Take the thermometer out of the charging unit, switch it on, and wait for the ready sign.
Step 3:
Gently slide the probe cover until a click is heard. This simple action prevents cross-contamination and ensures the correct placement of the probe cover.
Step 4:
Instruct the patient to open their mouth and place...
726
Thermosensation
30.3K
Peripheral thermosensation is the perception of external temperature. A change in temperature (on the surface of the skin and other tissues) is detected by a family of temperature-sensitive ion channels called Transient Receptor Potential, or TRP, receptors. These receptors are located on free nerve endings. Those detecting cold temperatures are closer to the surface of the skin than the nerve endings detecting warmth. These thermoTRP channels, while temperature selective, have relatively...
30.3K
Absorption of Radiation
703
The rate of heat transfer by emitted radiation is described by the Stefan-Boltzmann law of radiation:
703