基于水凝的植入物的复合对比增强用于光子计数计算机断层扫描研究研究
Evgeniya V Suslova1, Denis A Shashurin2, Konstantin I Maslakov1
1Department of Chemistry, Lomonosov Moscow State University, Leninskie Gory 1 Bld. 3, 119991 Moscow, Russia.
Gels (Basel, Switzerland)
|December 27, 2024
概括
这项研究使用基于化物 (Ln) 的对比剂提高了水凝植入物的可见性,用于光子计数计算机断层扫描 (PCCT). 这提高了安全性,使植入物在医学成像中能够清晰地检测到植入物.
科学领域:
- 生物材料科学 生物材料科学
- 医疗成像医学成像
- 纳米技术纳米技术
背景情况:
- 水凝在医疗植入物中广泛使用.
- 在传统的医学成像中,水凝的可见性有限,这可能会带来安全风险.
- 光子计数计算机断层扫描 (PCCT) 提供了改善成像的潜力.
研究的目的:
- 为了提高基于水凝的植入物的可见性,使用基于化物 (Ln) 的对比剂.
- 评估在PCCT中使用Ln基剂用于水凝可视化的可行性.
- 开发和评估用于植入物成像的基于Ln的新型对比剂.
主要方法:
- 用聚烯胺 (PAM) 合成交联纳米尺寸Ln2O3.
- 在凝和PAM水凝中加入基于Ln的对比剂.
- 在幻影PCCT研究中生产并评估了具有增强水凝填充物的原型植入物.
主要成果:
- 使用Ln基剂证明了水凝 (凝,PAM) 和外的对比度增强.
- 通过一种新的合成途径,成功地通过PAM与纳米尺寸的Ln2O3进行了交叉链接.
- 原型植入物在PCCT幻影研究中显示出更好的检测能力.
结论:
- 基于兰他尼德的对比剂可以显著提高PCCT中的水凝植入物可见性.
- 开发的Ln2O3-PAM纳米复合材料是医疗植入物的有希望的对比剂.
- 这种方法通过增强成像来提高可植入水凝系统的安全性.
相关概念视频
Computed Tomography
4.1K
Tomography refers to imaging by sections. Computed tomography (CT) is a non-invasive imaging technique that uses computers to analyze several cross-sectional X-rays to reveal minute details about structures in the body.
The technique was invented in the 1970s and is based on the principle that as X-rays pass through the body, they are absorbed or reflected at different levels. In the technique, a patient lies on a motorized platform while a computerized axial tomography (CAT) scanner rotates...
The technique was invented in the 1970s and is based on the principle that as X-rays pass through the body, they are absorbed or reflected at different levels. In the technique, a patient lies on a motorized platform while a computerized axial tomography (CAT) scanner rotates...
4.1K
Phase Contrast and Differential Interference Contrast Microscopy
7.2K
Phase-Contrast Microscopes
In-phase-contrast microscopes, interference between light directly passing through a cell and light refracted by cellular components is used to create high-contrast, high-resolution images without staining. It is the oldest and simplest type of microscope that creates an image by altering the wavelengths of light rays passing through the specimen. Altered wavelength paths are created using an annular stop in the condenser. The annular stop produces a hollow cone of...
In-phase-contrast microscopes, interference between light directly passing through a cell and light refracted by cellular components is used to create high-contrast, high-resolution images without staining. It is the oldest and simplest type of microscope that creates an image by altering the wavelengths of light rays passing through the specimen. Altered wavelength paths are created using an annular stop in the condenser. The annular stop produces a hollow cone of...
7.2K
X-ray Imaging
5.2K
German physicist Wilhelm Röntgen (1845–1923) was experimenting with electrical current when he discovered that a mysterious and invisible "ray" would pass through his flesh but leave an outline of his bones on a screen coated with a metal compound. In 1895, Röntgen made the first durable record of the internal parts of a living human: an "X-ray" image (as it came to be called) of his wife’s hand. Scientists worldwide quickly began their own experiments with...
5.2K


