相关实验视频
Updated: Jun 4, 2025

10:05
Colorimetric Detection of Bacteria Using Litmus Test
Published on: September 17, 2016
9.2K
一个无标签的DNA酶介导生物传感器用于 (II) 离子的光检测
Fatemeh Alinejad1, Zahra Khoshbin1, Mohammad Ramezani2
1Targeted Drug Delivery Research Center, Pharmaceutical Technology Institute, Mashhad University of Medical Sciences, Mashhad, Iran; Pharmaceutical Research Center, Pharmaceutical Technology Institute, Mashhad University of Medical Sciences, Mashhad, Iran; Department of Medicinal Chemistry, School of Pharmacy, Mashhad University of Medical Sciences, Mashhad, Iran.
Spectrochimica acta. Part A, Molecular and biomolecular spectroscopy
|December 27, 2024
概括
一个新的光生物传感器使用DNAzyme技术有效检测有毒的离子 (Pb2+). 这种方法提供了一种灵敏,方便和经济的方法来测量食品和生物样本中的含量.
科学领域:
- 环境科学 环境科学
- 生物技术是生物技术.
- 分析化学 分析化学
背景情况:
- 离子 (Pb2+) 是一种普遍存在的环境毒素,具有严重的健康影响.
- 农产品可以积累,通过饮食摄入带来风险.
- 现有的检测方法可能缺乏对现实应用的灵敏度或方便性.
研究的目的:
- 开发一种灵敏可靠的光生物传感器,用于检测离子 (Pb2+).
- 使用DNAzyme作为识别元件和SYBR绿色作为检测信号指示器.
- 为了验证生物传感器在血清和牛奶等复杂矩阵中的性能.
主要方法:
- 设计了一种基于DNA酶的光生物传感策略.
- 生物传感器依赖于Pb2+-依赖的DNA酶活性来切割基质.
- 裂隙改变了SYBR绿色间歇,调节了光信号.
主要成果:
- 生物传感器检测到Pb2+在0.1600μM的范围内.
- 达到了0.018μM的低检测极限.
- 在血清和牛奶样本中观察到高恢复率 (96.81100.00%).
结论:
- 成功开发了一种敏感的,无标签的光生物传感器,用于Pb2+检测.
- 基于DNA酶的方法是方便,高效和经济的.
- 这种生物传感器在各种样本中显示出准确的离子监测的前景.
相关概念视频
Labeling DNA Probes
8.1K
DNA probes are fragments of DNA labeled with a reporter tag to enable their detection or purification. The resulting labeled DNA probes can then hybridize to target nucleic acid sequences through complementary base-pairing, and may be used to recover or identify these regions.
Radioisotopes, fluorophores, or small molecule binding partners like biotin or digoxigenin, are the most widely used reporter tags for labeling DNA probes. These labels can be attached to the probe DNA molecule via...
Radioisotopes, fluorophores, or small molecule binding partners like biotin or digoxigenin, are the most widely used reporter tags for labeling DNA probes. These labels can be attached to the probe DNA molecule via...
8.1K
Photoluminescence: Applications
374
Photoluminescence offers a wide range of applications due to its inherent sensitivity and selectivity. This technique allows for both direct and indirect analyses of the analyte. Direct quantitative analysis is possible when the analyte exhibits a favorable quantum yield for fluorescence or phosphorescence. However, an indirect analysis may be feasible if the analyte is not fluorescent or phosphorescent, or if the quantum yield is unfavorable. Indirect methods include reacting the analyte with...
374