在直布罗陀海峡进行合声和多普勒分析仪测量
Simone Sammartino1,2, Jesús García-Lafuente3,4, Irene Nadal3,4
1Physical Oceanography Group, University of Málaga, Málaga, Spain. ssammartino@ctima.uma.es.
Scientific reports
|December 29, 2024
概括
动物浮游生物的迁移导致直布罗陀海峡的海流在白天明显减弱. 这一发现揭示了地中海外流计算中的低估值,需要重新分析长期数据.
科学领域:
- 海洋学 海洋学 海洋学
- 物理海洋学 物理海洋学
- 海洋生态海洋生态学
背景情况:
- 在直布罗陀海峡的声学造型仪检测到深水中昼间速度意外减弱.
- 波分析揭示了在水平速度和回声幅度中占主导地位的S1组成部分.
研究的目的:
- 调查在直布罗陀海峡白天速度减弱的原因.
- 评估这种现象对地中海外流估计的影响.
主要方法:
- 从前的声学分析师的长时间序列的分析.
- 对速度和回声幅度数据的波分析.
- 高分辨率声谱和近海底速度测量.
主要成果:
- 动物浮游生物的迪尔垂直迁移被确定为明显速度减弱的原因.
- 在以前的研究中,地中海海流被低估了约17%,而外流则被低估了约5%.
- 新的数据需要重新计算近20年的地中海外流系列.
结论:
- 动物浮游生物的垂直迁移对直布罗陀海峡的声速测量产生了重大影响.
- 以前对地中海外流的估计可能是不准确的,因为这个被忽视的因素.
- 为了准确的长期海洋学评估,需要修订计算.
相关概念视频
Electronic Distance Measuring Instruments
13
Electronic Distance Measuring Instruments (EDMs) are essential tools in modern surveying, offering precise distance measurements by emitting electromagnetic signals and calculating the time required for these signals to travel to a target and return. Two primary types of signals are used in EDMs — light waves and microwaves — each suited to specific environmental and distance requirements. Light-wave-based EDMs utilize either infrared or laser light, providing high accuracy over short...
13
Echo
461
The human ear cannot distinguish between two sources of sound if they happen to reach within a specific time interval, typically 0.1 seconds apart. More than this, and they are perceived as separate sources.
Imagine the sound is reflected back to the ears. Assuming that the source is very close to the human, the difference between hearing the two sounds—the emitted sound and the reflected sound—may be more than the minimum time for perceiving distinct sounds. If this is the case,...
Imagine the sound is reflected back to the ears. Assuming that the source is very close to the human, the difference between hearing the two sounds—the emitted sound and the reflected sound—may be more than the minimum time for perceiving distinct sounds. If this is the case,...
461
Equipments Used To Measure Blood Pressure
762
Direct Method
This invasive approach involves cannulating a peripheral artery. During each cardiac contraction, pressure generates mechanical motion within the catheter, transmitted through rigid, fluid-filled tubing to a transducer. This transducer converts mechanical motion into electrical signals displayed as waveforms on a monitor. An automatic flushing system prevents blood backflow. Due to the potential risk of unexpected arterial blood loss, this method is primarily used in intensive...
This invasive approach involves cannulating a peripheral artery. During each cardiac contraction, pressure generates mechanical motion within the catheter, transmitted through rigid, fluid-filled tubing to a transducer. This transducer converts mechanical motion into electrical signals displayed as waveforms on a monitor. An automatic flushing system prevents blood backflow. Due to the potential risk of unexpected arterial blood loss, this method is primarily used in intensive...
762


