基于stilbene的光化学传感器用于选择性检测DMSO介质中的化物离子,并用于细胞成像,指纹和食品样本分析
Chinnaraj Yesudhasan1, Ayyanar Siva1, Govindan Shanmugam2
1Supramolecular and Organometallic Chemistry Lab, Department of Inorganic Chemistry, School of Chemistry, Madurai Kamaraj University, Madurai 21, India.
Spectrochimica acta. Part A, Molecular and biomolecular spectroscopy
|December 30, 2024
概括
开发了一种新的光探针NCS,用于敏感和选择性的化物检测. 这个探测器在与化物离子结合时表现出一个关闭光反应,使环境和生物传感中的应用成为可能.
科学领域:
- 分析化学 分析化学
- 材料科学 材料科学 材料科学
- 化学传感器 化学传感器
背景情况:
- 化物是一种高度有毒的环境污染物.
- 选择性和敏感的化物传感器的开发对于安全和监测至关重要.
- 光探针在灵敏度和实时检测方面具有优势.
研究的目的:
- 设计和合成一种用于化物检测的新型光探针.
- 为了评估探测器的选择性,灵敏度和传感机制.
- 探索探测器在各种系统中的潜在应用.
主要方法:
- 一步合成 (Z) - 3 - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - 甲基硫) - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - 甲基) 烯基 (NCS) 探针的一步合成.
- 紫外线和光光谱用于评估.
- 1H NMR定位,FT-IR,乔布斯图,DFT计算和质谱测量以阐明机制.
主要成果:
- 该NCS探测器表现出光与化物离子 (CN−) 的关闭反应.
- 探测器显示出对化物比其他离子具有很高的选择性和敏感性.
- 在NCS和CN−之间确定了1:1的固体测量,检测极限为1.14μM.
- 检测机制被确定为分子内电荷转移 (ICT) 干扰.
结论:
- 开发的NCS探头是选择性和敏感的化物检测的有希望的工具.
- 探测器的机制涉及化物对核友的攻击,破坏ICT.
- 潜在的应用包括环境监测,生物成像和通过测试条检测隐性指纹.
相关概念视频
Labeling DNA Probes
8.1K
DNA probes are fragments of DNA labeled with a reporter tag to enable their detection or purification. The resulting labeled DNA probes can then hybridize to target nucleic acid sequences through complementary base-pairing, and may be used to recover or identify these regions.
Radioisotopes, fluorophores, or small molecule binding partners like biotin or digoxigenin, are the most widely used reporter tags for labeling DNA probes. These labels can be attached to the probe DNA molecule via...
Radioisotopes, fluorophores, or small molecule binding partners like biotin or digoxigenin, are the most widely used reporter tags for labeling DNA probes. These labels can be attached to the probe DNA molecule via...
8.1K
Photoluminescence: Applications
374
Photoluminescence offers a wide range of applications due to its inherent sensitivity and selectivity. This technique allows for both direct and indirect analyses of the analyte. Direct quantitative analysis is possible when the analyte exhibits a favorable quantum yield for fluorescence or phosphorescence. However, an indirect analysis may be feasible if the analyte is not fluorescent or phosphorescent, or if the quantum yield is unfavorable. Indirect methods include reacting the analyte with...
374