温度对不和土壤的母体吸收的影响:实验见解
Feifei Liu1, Cheng Xu2, Mingming Ba1
1School of Civil Engineering and Architecture, Henan University of Technology, Zhengzhou, 450001, Henan, China.
Scientific reports
|January 6, 2025
概括
温度显著影响土壤矩阵吸收. 随着温度的升高,矩阵吸收减少,土表现出比沙子更高的灵敏度. 这项研究提供了对不和土壤温度影响的见解.
科学领域:
- 地质技术工程 地质技术工程
- 土壤物理 土壤物理
- 环境科学 环境科学
背景情况:
- 在不和土壤中,矩阵吸收受温度的影响.
- 了解这种关系对于分析土壤行为至关重要.
- 以前的研究已经探讨了温度的影响,但需要进一步的研究.
研究的目的:
- 研究温度和水分含量对土和沙土中母吸的温度依赖性的影响.
- 评估三种数据适配模型 (Brooks-Corey,van Genuchten,Fredlund-Xing) 在0°C以上的矩阵吸收的性能.
- 为了分类矩阵吸取与温度的变化.
主要方法:
- 在不同温度和水分含量下,对土和沙土的矩阵吸收进行实验性研究.
- 使用Brooks-Corey,van Genuchten和Fredlund-Xing模型进行数据分析和拟合.
- 将矩阵吸气温度关系分类为不同的灵敏度范围 (RMax,RTS,RTW).
主要成果:
- 随着温度的增加,矩阵吸收会减少.
- 矩阵吸管的温度灵敏度随着水分含量而变化,显示出不同的范围 (RMax,RTS,RTW).
- 土表现出比沙土更高的温度灵敏度;van Genuchten模型显示最适合在0°C以上.
结论:
- 温度是影响不和土壤母体吸收的关键因素.
- 含水量调节了矩阵吸管的温度灵敏度.
- 范Genuchten模型为0°C以上的矩阵吸气温度关系提供了可靠的适配.
更多相关视频
07:21Author Spotlight: Advancing Agricultural Land Ecosystem Research with a Hydraulic Property Analyzer to Assess Soil Health
Published on: August 9, 2024
918
08:09Wastewater Irrigation Impacts on Soil Hydraulic Conductivity: Coupled Field Sampling and Laboratory Determination of Saturated Hydraulic Conductivity
Published on: August 19, 2018
9.1K
相关概念视频
Porosity and Absorption of Aggregate
255
Aggregates contain pores of varying sizes; while some are completely enclosed within the particles, others open onto the surface, allowing water to penetrate. The porosity of aggregates is a major factor contributing to the overall porosity of concrete, given that aggregates constitute about three-quarters of concrete's volume.
When all pores in an aggregate are filled with water, the aggregate is considered saturated and surface-dry. If left in dry air, water will evaporate until the...
When all pores in an aggregate are filled with water, the aggregate is considered saturated and surface-dry. If left in dry air, water will evaporate until the...
255
Design Example: Managing Concrete Workability
71
This example deals with managing the workability of concrete for a raft foundation project under hot weather conditions. Workability is crucial for ensuring the concrete is easy to place, compact, and finish. In this scenario, a slump test — a common method to measure the workability of fresh concrete — initially indicated low workability. This was attributed to the rapid water loss from the concrete mix, exacerbated by the high temperatures causing the course aggregates to heat up.
71
Surface Tension of Fluid
222
Surface tension is a fundamental property of fluids, occurring at the boundary between a liquid and a gas or between two immiscible liquids. This phenomenon arises from the cohesive forces between molecules at the fluid's surface, creating an effect similar to a stretched elastic membrane. Inside each fluid, molecules are equally attracted in all directions by neighboring molecules, but surface molecules experience a net inward force, resulting in surface tension.
Surface tension varies...
Surface tension varies...
222