查淋巴超声波检测淋巴功能障碍
相关实验视频
Updated: Jun 3, 2025

05:44
Ultrasonographic Evaluation of Breast Cancer-related Lymphedema
Published on: January 12, 2017
10.0K
Hisako Hara1,2, Makoto Mihara2
1Department of Lymphatic and Reconstructive Surgery, JR Tokyo General Hospital, Tokyo, Japan.
Lymphatic research and biology
|January 8, 2025
概括
查性淋巴超声波 (SLUS) 有效地评估腿部淋巴患者的淋巴功能. 这种非侵入性方法可以识别淋巴血管的异常,有助于诊断和治疗计划.
科学领域:
- 血管超声波是指血管超声波.
- 淋巴的诊断 淋巴的诊断 淋巴的诊断
- 淋巴细胞成像系统的成像
背景情况:
- 非对比的淋巴超声波提供更高的分辨率,并且比对比方法更少的侵入性.
- 目前用于淋巴功能的诊断方法需要改进.
研究的目的:
- 评估查性淋巴超声波 (SLUS) 的有用性,以评估腿部淋巴患者的淋巴功能.
- 为了将SLUS发现与已确定的淋巴图学指标相关联.
主要方法:
- 追溯分析22名患有腿部淋巴的患者接受SLUS.
- SLUS涉及将腿和脚分为特定区域,使用NECST系统对发现进行分类.
- 使用D-CUPS标准区分淋巴血管和静脉;在一小部分患者中进行了印ocyanine绿色 (ICG) 淋巴图.
主要成果:
- 在SLUS中,中部大腿和小腿的淋巴血管的识别率很高 (95.5%).
- 狂喜类型的淋巴发现在中间腿上更为普遍.
- 在SLUS发现 (狂喜,正常,没有发现) 和皮肤回流状态 (p < 0.01) 之间发现了显著的相关性.
结论:
- 查淋巴超声波 (SLUS) 是评估淋巴血管功能的一个有价值的工具.
- SLUS发现与皮肤逆流相关,支持其在淋巴的诊断效用.
相关概念视频
Ultrasound II: Endoscopic Ultrasound and FibroScan
76
Endoscopic Ultrasound (EUS) and FibroScan are valuable diagnostic tools in gastroenterology and hepatology, each with specific applications and techniques.
Endoscopic Ultrasound (EUS):
Endoscopic Ultrasound (EUS):
76
Ultrasonography
4.3K
Ultrasonography is an imaging technique that uses high-frequency sound waves to visualize the body's internal structures. It is a non-invasive and safe procedure that does not involve the use of ionizing radiation, making it widely used in various medical fields. Ultrasonography is used to study heart function, blood flow in the neck or extremities, certain conditions such as gallbladder disease, and fetal growth and development.
During an ultrasonography procedure, a handheld device called...
During an ultrasonography procedure, a handheld device called...
4.3K
Assessment of the Cardiovascular System III: Palpation
189
Palpation involves feeling the body to evaluate texture, size, consistency, and tenderness for assessing cardiovascular health. The following steps are organized in a head-to-toe order:
Jugular Venous Pressure (JVP) Measurement
Position the patient at a thirty- to forty-five-degree angle or in a semi-fowler's position. Look for the highest point of pulsation in the internal jugular vein and measure the vertical distance to the angle of Loius or sternal angle. A normal JVP is 3-4 cm above...
Jugular Venous Pressure (JVP) Measurement
Position the patient at a thirty- to forty-five-degree angle or in a semi-fowler's position. Look for the highest point of pulsation in the internal jugular vein and measure the vertical distance to the angle of Loius or sternal angle. A normal JVP is 3-4 cm above...
189

