在延迟识别前厅中错位的电极阵列中学到的教训
Huey Ting Diong1, Yuhan Wong2,3, Shermaine Png1
1Department of Audiology, Ng Teng Fong General Hospital, 1 Jurong East Street 21, Singapore, 609606, Singapore.
Journal of otology
|January 8, 2025
概括
一个耳植入物电极阵列被错误地放置在前厅,导致尽管听力正常,但语音表现不佳. 由于患者缺乏典型的前体症状,导致识别延迟.
科学领域:
- 耳鼻喉科 耳鼻喉科 耳鼻喉科
- 神经外科 神经外科
- 听力学 听力学是指听力学.
背景情况:
- 耳植入是严重听力损失的常见治疗方法.
- 精确的电极放置对于最佳的设备功能至关重要.
- 电极错位,特别是在前厅,可能会导致低于最佳的结果.
研究的目的:
- 报告一例耳植入与前厅的电极阵列错位的情况.
- 为了调查这种错位的延迟识别的原因.
- 突出考虑耳植入体接受者的非典型表现的重要性.
主要方法:
- 一名23岁的男性患有单侧耳聋,接受了耳植入.
- 进行了手术内评估和术后听力学评估.
- 高分辨率计算机断层扫描 (HRCT) 和神经响应遥测 (NRT) 用于诊断.
- 进行了修复手术.
主要成果:
- 电极阵列在HRCT的前厅中完全被发现.
- 尽管有良好的辅助听力值,但患者表现不佳的言语表现.
- 追溯NRT分析显示了微妙的响应差异.
- 患者没有表现出前庭症状,这是由于先前存在的耳石软弱.
结论:
- 电极错位的延迟识别可能会发生,即使没有典型的前庭症状.
- 非典型的表现需要彻底的调查,包括先进的成像和电生理学测试.
- 需要进一步的研究,以了解前厅内电极错位的情况下的结果.
相关概念视频
The Hall Effect
Edwin H. Hall, in the year 1879, devised an experiment that could be used to identify the polarity of the predominant charge carriers in a conducting material. From a historical perspective, this experiment was the first to demonstrate that the charge carriers in most metals are negative.
Inductors
An inductor, also known as a choke, is a circuit component created to have a specific inductance. Inductors are among the crucial circuit components used in modern electronics, along with resistors and capacitors. They serve as a barrier against changes in a circuit's current. An inductor tends to suppress current changes in an alternating-current circuit that are faster than desired. In a direct-current circuit, an inductor aids in preserving a constant current despite changes in the applied...
PI Controller: Design
Proportional Integral (PI) controllers are a fundamental component in modern control systems, widely used to enhance performance and mitigate steady-state errors. They are particularly effective in applications such as automatic brightness adjustment on smartphones, where they excel at mitigating steady-state errors for step-function inputs. Unlike PD controllers, which require time-varying errors to function optimally, PI controllers leverage their integral component to address residual...
Power System Three-Phase Short Circuits
Determining the subtransient fault current in a power system involves representing transformers by their leakage reactances, transmission lines by their equivalent series reactances, and synchronous machines as constant voltage sources behind their subtransient reactances. In this analysis, certain elements are excluded, such as winding resistances, series resistances, shunt admittances, delta-Y phase shifts, armature resistance, saturation, saliency, non-rotating impedance loads, and small...
Line Protection with Impedance Relays
Coordinating time-delay overcurrent relays in complex radial systems and directional overcurrent relays in multi-source transmission loops can be challenging. Impedance relays address these issues by responding to the voltage-to-current ratio, specifically measuring the apparent impedance of a line. These relays become more sensitive during faults as current increases and voltage decreases, thereby reducing the apparent impedance.
Under normal conditions, low load currents keep the measured...
Under normal conditions, low load currents keep the measured...
Common Leveling Mistakes and Errors
A survey team is tasked with determining the elevation difference between points Point A and Point B, separated by uneven terrain. They use a leveling instrument and a leveling rod.Common MistakesMisreading the Rod: During a backsight reading at Point A, the instrumentman observes the rod partially obscured by tall grass. Instead of reading 1.135 m, they mistakenly record 1.735 m due to the misalignment of the crosshair with the wrong graduation. This error adds 0.600 m to all subsequent...