一个双闭环数字液压气定位系统,基于切换主动干扰排斥控制
Shouling Jiang1,2, Guochao Zhao3, Fuxian Huang1
1School of Computer, Heze University, No.2269, Daxue Road, Heze, 274015, Shandong, China.
Scientific reports
|January 9, 2025
概括
一种新的开关主动干扰排斥控制 (SADRC) 策略通过克服复合干扰来增强数字液压气控制. 这种先进的方法提高了32.56%的响应速度,与PID控制相比.
科学领域:
- 控制系统工程 控制系统工程
- 液压系统 水力系统
- 机器人技术 机器人技术 机器人技术
背景情况:
- 数字液压气面临复杂的干扰,如摩擦和外部负荷.
- 现有的控制方法与这些系统的非线性动态作斗争.
研究的目的:
- 为数字液压气位置控制制定一个强大的控制策略.
- 解决双闭环系统中的复合干扰问题.
主要方法:
- 从系统的数学模型中推导高阶状态方程.
- 将系统转换为使用主动干扰拒绝控制 (ADRC) 的二阶整列控制系统.
- 关于切换主动干扰拒绝控制 (SADRC) 策略的建议和稳定性分析 (利亚普诺夫理论).
主要成果:
- 萨德克的战略在PID控制方面表现优越.
- 实现了32.56%的响应速度改善和2.0%的错误减少.
- 模拟和实验结果显示出一致的趋势,验证了控制策略的可行性.
结论:
- 拟议的SADRC战略有效地管理数字液压气中的复合干扰.
- 该方法在控制准确性和速度方面提供了显著的改进.
- 通过模拟和实验验证实可行性和有效性.
更多相关视频
11:53The Modular Design and Production of an Intelligent Robot Based on a Closed-Loop Control Strategy
Published on: October 14, 2017
11.6K
11:44Real-Time DC-dynamic Biasing Method for Switching Time Improvement in Severely Underdamped Fringing-field Electrostatic MEMS Actuators
Published on: August 15, 2014
10.3K
相关概念视频
Open and closed-loop control systems
634
Control systems are foundational elements in automation and engineering. They are broadly categorized into open-loop and closed-loop systems. These classifications hinge on the presence or absence of feedback mechanisms, significantly influencing the system's performance, complexity, and application.
An open-loop control system operates without feedback from the output. It consists of two primary elements: the controller and the controlled process. The controller receives an input signal...
An open-loop control system operates without feedback from the output. It consists of two primary elements: the controller and the controlled process. The controller receives an input signal...
634
PD Controller: Design
183
In automotive engineering, car suspension systems often employ Proportional Derivative (PD) controllers to enhance performance. PD controllers are utilized to adjust the damping force in response to road conditions. A controller, acting as an amplifier with a constant gain, demonstrates proportional control, with output directly mirroring input.
Designing a continuous-data controller requires selecting and linking components like adders and integrators, which are fundamental in Proportional,...
Designing a continuous-data controller requires selecting and linking components like adders and integrators, which are fundamental in Proportional,...
183
Time-Domain Interpretation of PD Control
83
Proportional-Derivative (PD) control is a widely used control method in various engineering systems to enhance stability and performance. In a system with only proportional control, common issues include high maximum overshoot and oscillation, observed in both the error signal and its rate of change. This behavior can be divided into three distinct phases: initial overshoot, subsequent undershoot, and gradual stabilization.
Consider the example of control of motor torque. Initially, a positive...
Consider the example of control of motor torque. Initially, a positive...
83
Feedback control systems
281
Feedback control systems are categorized in various ways based on their design, analysis, and signal types.
Linear feedback systems are theoretical models that simplify analysis and design. These systems operate under the principle that their output is directly proportional to their input within certain ranges. For instance, an amplifier in a control system behaves linearly as long as the input signal remains within a specific range. However, most physical systems exhibit inherent nonlinearity...
Linear feedback systems are theoretical models that simplify analysis and design. These systems operate under the principle that their output is directly proportional to their input within certain ranges. For instance, an amplifier in a control system behaves linearly as long as the input signal remains within a specific range. However, most physical systems exhibit inherent nonlinearity...
281
Control System Problem
104
In an open-loop system, such as a basic thermostat, the poles of the transfer function influence the system's response but do not determine its stability. However, when feedback is introduced to form a closed-loop system, such as an advanced thermostat that adjusts heating based on room temperature, stability is governed by the new poles of the closed-loop transfer function.
When forming a closed-loop system, issues can arise if the poles cross into the unstable region, leading to potential...
When forming a closed-loop system, issues can arise if the poles cross into the unstable region, leading to potential...
104
Multi-input and Multi-variable systems
96
Cruise control systems in cars are designed as multi-input systems to maintain a driver's desired speed while compensating for external disturbances such as changes in terrain. The block diagram for a cruise control system typically includes two main inputs: the desired speed set by the driver and any external disturbances, such as the incline of the road. By adjusting the engine throttle, the system maintains the vehicle's speed as close to the desired value as possible.
In the absence...
In the absence...
96