在水性介质中使用有机配体作为光探针检测Pb2+离子的微量检测
Maria Sadia1, Jehangir Khan1, Rizwan Khan2
1Department of Chemistry, University of Malakand, Chakdara, Lower Dir, Khyber Pakhtunkhwa, Pakistan.
Heliyon
|January 13, 2025
概括
一个新的光学传感器,JA,高效地检测离子 (Pb2+),具有高选择性,即使存在干扰离子. 这种可重复使用的传感器显示了在真实样本中用于检测的实际应用.
科学领域:
- 分析化学 分析化学
- 材料科学 材料科学 材料科学
- 环境科学 环境科学
背景情况:
- 离子 (Pb2+) 具有重大环境和健康风险.
- 开发用于重金属检测的选择性和敏感传感器至关重要.
- 光学传感器在灵敏度和实时监控方面具有优势.
研究的目的:
- 为了合成和描述一种新的光学传感器,JA.
- 为了评估传感器对Pb2+检测的效率和选择性.
- 评估传感器在真实样本中的实际适用性.
主要方法:
- 使用1H NMR和FT-IR光谱学合成和描述JA.
- 用于研究JA-Pb2+相互作用的光度分析和吸收光谱学.
- 密度函数理论 (DFT) 用于理论计算.
- 在优化条件下的真实样本分析.
主要成果:
- 对于Pb2+而言,JA对其他金属离子具有很高的选择性.
- 光强度在Pb2+结合时显著增强,表明复杂的形成.
- 证实了JA和Pb2+之间的2:1结合比.
- 对于Pb2+的检测极限低至5 x 10^-7 M.
- 传感器使用EDTA证明了可重复使用性.
结论:
- JA是用于Pb2+检测的高效和选择性的光学传感器.
- 传感器表现出极好的灵敏度和低检测极限.
- JA显示了对现实世界Pb2+监控的实际应用性,并且可以重复使用.
相关概念视频
Labeling DNA Probes
8.1K
DNA probes are fragments of DNA labeled with a reporter tag to enable their detection or purification. The resulting labeled DNA probes can then hybridize to target nucleic acid sequences through complementary base-pairing, and may be used to recover or identify these regions.
Radioisotopes, fluorophores, or small molecule binding partners like biotin or digoxigenin, are the most widely used reporter tags for labeling DNA probes. These labels can be attached to the probe DNA molecule via...
Radioisotopes, fluorophores, or small molecule binding partners like biotin or digoxigenin, are the most widely used reporter tags for labeling DNA probes. These labels can be attached to the probe DNA molecule via...
8.1K
Photoluminescence: Applications
372
Photoluminescence offers a wide range of applications due to its inherent sensitivity and selectivity. This technique allows for both direct and indirect analyses of the analyte. Direct quantitative analysis is possible when the analyte exhibits a favorable quantum yield for fluorescence or phosphorescence. However, an indirect analysis may be feasible if the analyte is not fluorescent or phosphorescent, or if the quantum yield is unfavorable. Indirect methods include reacting the analyte with...
372
Extraction: Advanced Methods
407
Metal ions can be separated from one another by complexation with organic ligands–the chelating agent– to form uncharged chelates. Here, the chelating agent must contain hydrophobic groups and behave as a weak acid, losing a proton to bind with the metal. Since most organic ligands used in this process are insoluble or undergo oxidation in the aqueous phase, the chelating agent is initially added to the organic phase and extracted into the aqueous phase. The metal-ligand complex is...
407


