一个热极化,溶相的Xe幻影用于气体交换成像质量控制和多站点比较
Matthew M Willmering1, Brice J Albert2, Joseph W Plummer3
1Center for Pulmonary Imaging Research (CPIR), Division of Pulmonary Medicine Cincinnati Children's Hospital Medical Center Cincinnati OH USA; Department of Pediatrics, University of Cincinnati OH USA.
Journal of magnetic resonance (San Diego, Calif. : 1997)
|January 14, 2025
概括
新的幽灵模仿人类的肺129Xe光谱特性用于成像. 这些具有短T1时间的定量,溶解相幻体将有助于在临床试验中标准化气体交换成像.
科学领域:
- 医疗成像医学成像
- 生物物理学的生物物理.
- 化学工程是化学工程的重要组成部分.
背景情况:
- 协调多站点的Xe气交换成像需要定量标准.
- 现有的方法缺乏复制体内129Xe光谱属性的幻影,并且具有实际的T1次成像.
研究的目的:
- 开发和演示溶相,热极化Xe幻影.
- 这些幻影的目标是模仿体内红细胞 (RBC) 和肺膜共振,用于定量成像.
主要方法:
- 使用乙和二甲基硫氧化物创建了两个溶解相129Xe幻影.
- 铁(iii) 乙氨酸兴奋剂降低了纵向放松时间 (T1) 在3T和7T的1.2s.
- 幻影稳定性在一年内进行了评估,显示了最小的化学转移和T1变化.
主要成果:
- 幻象在体内表现出类似于129的Xe化学转移 (212.4 ppm和193.9 ppm).
- 溶相图像实现了信号噪声比 (SNR) 的6 (RBC) 和12 (膜) 的3mm2分辨率.
- 模拟的临床体积表明,在不到一分钟的时间里,红细胞幻体的SNR为7.
结论:
- 强大,定量,热极化溶相Xe幻影成功制造.
- 这些幻影在多个地点的临床试验中为验证和协调Xe气交换成像提供了至关重要的工具.
相关概念视频
X-ray Imaging
German physicist Wilhelm Röntgen (1845–1923) was experimenting with electrical current when he discovered that a mysterious and invisible "ray" would pass through his flesh but leave an outline of his bones on a screen coated with a metal compound. In 1895, Röntgen made the first durable record of the internal parts of a living human: an "X-ray" image (as it came to be called) of his wife’s hand. Scientists worldwide quickly began their own experiments with X-rays, and by 1900, X-ray was widely...
Atomic Emission Spectroscopy: Overview
Atomic emission spectroscopy (AES) is an analytical technique used to determine the elemental composition of a sample by analyzing the light emitted from excited atoms. In AES, atoms in a sample are excited to higher energy levels by thermal energy from high-temperature sources, such as plasma, arcs, or sparks. When these excited atoms return to lower energy states, they emit light at specific wavelengths characteristic of each element. The resulting atomic emission spectrum, which consists of...
Atomic Emission Spectroscopy: Instrumentation
The instrumentation of atomic emission spectrometry (AES) involves various components, including atomization devices that convert samples into gas-phase atoms and ions. There are two main types of atomization devices: continuous and discrete atomizers. Continuous atomizers, like plasmas and flames, introduce samples in a constant stream, while discrete atomizers inject individual samples using syringes or autosamplers. The most common discrete atomizer is the electrothermal atomizer.
Atomic Emission Spectroscopy: Interference
In atomic emission spectroscopy (AES), high-temperature atomizers excite a broad range of elements and molecules that generate complex emissions from sources such as oxides, hydroxides, and flame combustion products in the flame or plasma. Several strategies can be employed to minimize spectral interferences caused by overlapping emission lines or bands. These include increasing instrument resolution, choosing alternative emission lines, optimally placing the detector in low-background regions,...
Inductively Coupled Plasma Atomic Emission Spectroscopy: Instrumentation
Inductively coupled plasma (ICP) is the common plasma source used in atomic emission spectroscopy (AES), a technique that detects and analyzes various elements in a sample. This method is often called inductively coupled plasma atomic emission spectroscopy (ICP-AES).
There are three main types of inductively coupled plasma atomic emission spectroscopy (ICP-AES) instruments: sequential, simultaneous multichannel, and Fourier transform instruments, with the latter being less commonly used.
There are three main types of inductively coupled plasma atomic emission spectroscopy (ICP-AES) instruments: sequential, simultaneous multichannel, and Fourier transform instruments, with the latter being less commonly used.
Atomic Emission Spectroscopy: Lab
AES is a powerful analytical technique, especially effective when used with plasma sources, producing abundant spectra in characteristic emission lines. The Inductively Coupled Plasma (ICP), in particular, yields superior quantitative analytical data due to its high stability, low noise, low background, and minimal interferences under optimal experimental conditions. However, newer air-operated microwave sources are emerging as promising alternatives that could be more cost-effective than...