在动脉化的静脉上缺血预条件:温度效应和监测
Rani Septrina1, Ronny Lesmana2, Reno Rudiman1
1Department of Surgery, Faculty of Medicine Universitas Padjadjaran, Bandung, Indonesia.
Journal of stomatology, oral and maxillofacial surgery
|January 14, 2025
概括
缺血预先调节通过增加膜温度来改善动脉化的静脉膜存活率. 这项研究使用热成像监测了膜温度,显示了人类临床应用的有希望的结果.
科学领域:
- 整形外科 整形外科 整形外科
- 血管外科 血管外科
- 再生医学是一种再生医学.
背景情况:
- 动脉化静脉 (AVFs) 易受转移期间缺血性再输液损伤的影响.
- 缺血预调 (IP) 提供了保护,并提高了片的存活率.
- 膜温度是生存的可靠指标,但AVF温度数据有限.
研究的目的:
- 为了研究IP对动脉化静脉膜温度的影响.
- 建立一种使用热成像监测AVF温度的方法.
主要方法:
- 雄性Wistar大鼠被分为对照组和IP组 (紧5或10分钟的3个周期).
- 进行了表面上表胃动脉和静脉解剖.
- 在手术前和手术后使用基于安卓的热摄像头监测膜温度.
主要成果:
- 所有的板都存活了下来 (N=26).
- 与对照组相比,IP组在4-6天 (EX1) 显示出显著的温度增加,并在2-21天 (EX2) 保持稳定的温度.
- 热成像提供了简单的板监控.
结论:
- 在早期的术后期,IP会增加动脉化的静脉膜温度.
- 热摄像头监控是AVF评估的一个可行的方法.
- 这些发现表明,在人类AVF手术中可能有临床应用.
相关概念视频
Assessing Body Temperature - Temporal Artery
Here is a stepwise guide to assessing the body temperature at the temporal artery using a temporal artery thermometer
Step 1: Perform hand hygiene and don a fresh pair of gloves to prevent cross-infection and ensure patient safety.
Step 2: Explain the procedure to the patient to establish trust. Clear communication establishes trust with the patient, ensures they understand what to expect, promotes cooperation, and enhances comfort during the procedure.
Step 3: Assess the patient's forehead...
Step 1: Perform hand hygiene and don a fresh pair of gloves to prevent cross-infection and ensure patient safety.
Step 2: Explain the procedure to the patient to establish trust. Clear communication establishes trust with the patient, ensures they understand what to expect, promotes cooperation, and enhances comfort during the procedure.
Step 3: Assess the patient's forehead...
Equipments Used To Measure Blood Pressure
Direct Method
This invasive approach involves cannulating a peripheral artery. During each cardiac contraction, pressure generates mechanical motion within the catheter, transmitted through rigid, fluid-filled tubing to a transducer. This transducer converts mechanical motion into electrical signals displayed as waveforms on a monitor. An automatic flushing system prevents blood backflow. Due to the potential risk of unexpected arterial blood loss, this method is primarily used in intensive...
This invasive approach involves cannulating a peripheral artery. During each cardiac contraction, pressure generates mechanical motion within the catheter, transmitted through rigid, fluid-filled tubing to a transducer. This transducer converts mechanical motion into electrical signals displayed as waveforms on a monitor. An automatic flushing system prevents blood backflow. Due to the potential risk of unexpected arterial blood loss, this method is primarily used in intensive...
Assessing Blood pressure using a doppler ultrasound
To obtain accurate blood pressure measurements in clinical settings, especially when traditional methods are insufficient, healthcare professionals utilize the Doppler ultrasound technique. This method uses high-frequency sound waves to detect blood flow within the arteries, which is crucial for patients with conditions that complicate circulatory system assessment.
Pre-Procedural Guidelines for Doppler Ultrasound Blood Pressure Assessment:
Preparation of Equipment:
Pre-Procedural Guidelines for Doppler Ultrasound Blood Pressure Assessment:
Preparation of Equipment:
Pre-Procedural Guidelines for Assessing Blood Pressure
Accurate blood pressure assessment is crucial for diagnosing and managing various health conditions. To ensure the reliability of these measurements, healthcare professionals must adhere to standardized pre-procedural guidelines. These guidelines enhance patient safety and improve the overall quality of healthcare. The following steps are essential for obtaining accurate and consistent blood pressure readings, from using the appropriate tools to ensuring effective communication with the patient.
Assessment of the Cardiovascular System III: Palpation
Palpation involves feeling the body to evaluate texture, size, consistency, and tenderness for assessing cardiovascular health. The following steps are organized in a head-to-toe order:
Jugular Venous Pressure (JVP) Measurement
Position the patient at a thirty- to forty-five-degree angle or in a semi-fowler's position. Look for the highest point of pulsation in the internal jugular vein and measure the vertical distance to the angle of Loius or sternal angle. A normal JVP is 3-4 cm above the...
Jugular Venous Pressure (JVP) Measurement
Position the patient at a thirty- to forty-five-degree angle or in a semi-fowler's position. Look for the highest point of pulsation in the internal jugular vein and measure the vertical distance to the angle of Loius or sternal angle. A normal JVP is 3-4 cm above the...
Cardiovascular System Abnormal Findings I: Inspection and Palpation
In a cardiovascular examination, inspection and palpation are crucial for identifying abnormalities.
Abnormal findings observed during an inspection
Abnormal findings observed during an inspection