维持电网电力控制中的情况评估
Mark W Wiggins1, Jaime C Auton2, Daniel Sturman2
1Macquarie University, Australia.
Human factors
|January 15, 2025
概括
保持在电力传输控制中的情况意识至关重要. 最近的培训和就业,而不是经验,预测了在不断变化的能源系统中持续的情况评估.
科学领域:
- 人类因素和人体工程学
- 认知心理学 认知心理学
- 电力系统工程 电力系统工程
背景情况:
- 由于可再生能源的整合,电力行业正在经历重大转型.
- 在电力传输控制中越来越依赖先进技术可能会影响情况评估.
- 网络控制器在系统复杂性和变化中面临着保持局势意识的挑战.
研究的目的:
- 调查有助于持续评估电力传输控制随时间推移的情况的因素.
- 了解工作角色和培训如何影响网络控制器评估复杂系统的能力.
主要方法:
- 来自三个组织的传输网络控制器参与了这项研究.
- 情况评估在两次单独的场合进行了评估,间隔一年.
- 使用统计分析,包括多重回归,以确定预测因素.
主要成果:
- 第二年情况评估在第一年的表现上显著预测了第二年的情况评估.
- 最近的正式培训和对工作的感知兴奋是关键预测因素.
- 多年作为网络控制器的经验并没有显示出与情况评估有重大关系.
结论:
- 最近的正式培训和对工作的积极看法对于保持情况评估至关重要.
- 职位设计和有针对性的培训策略可以支持在先进的技术环境中持续评估情况.
- 该研究强调了对能源部门关键角色的持续学习和参与的重要性.
相关概念视频
Multimachine Stability
140
Multimachine stability analysis is crucial for understanding the dynamics and stability of power systems with multiple synchronous machines. The objective is to solve the swing equations for a network of M machines connected to an N-bus power system.
In analyzing the system, the nodal equations represent the relationship between bus voltages, machine voltages, and machine currents. The nodal equation is given by:
In analyzing the system, the nodal equations represent the relationship between bus voltages, machine voltages, and machine currents. The nodal equation is given by:
140
Load-frequency control
119
Load-frequency control (LFC) is vital for maintaining power system stability, ensuring that frequency and power flows remain within acceptable limits during load changes. Turbine-governor control eliminates rotor accelerations and decelerations following load changes. However, a steady-state frequency error persists when the change in the turbine-governor reference setting is zero. In an interconnected power system, each area agrees to export or import a scheduled amount of power through...
119
Power System Distribution
226
Power system distribution involves delivering electrical energy from power plants to consumers through a network of transmission and distribution systems. The process begins at power plants, where energy from coal, gas, nuclear, water, and wind is converted into electrical energy. These plants use three-phase generators, typically rated between 50 to 1300 MVA, with terminal voltages ranging from a few kV to 20 kV, depending on the size and age of the units.
The transmission system is designed...
The transmission system is designed...
226
Control of Power Flow
251
There are several methods to control power flow in power systems:
251
Power System Three-Phase Short Circuits
74
Determining the subtransient fault current in a power system involves representing transformers by their leakage reactances, transmission lines by their equivalent series reactances, and synchronous machines as constant voltage sources behind their subtransient reactances. In this analysis, certain elements are excluded, such as winding resistances, series resistances, shunt admittances, delta-Y phase shifts, armature resistance, saturation, saliency, non-rotating impedance loads, and small...
74
Distribution Reliability and Automation
105
Distribution reliability in electrical power systems is critical for ensuring an uninterrupted power supply to consumers at minimal cost. According to IEEE Standard Terms, reliability is the probability that a device will function without failure over a specified time period or amount of usage. For electric power distribution, this translates to maintaining continuous power supply and addressing customer concerns over power outages. Several indices, as defined by IEEE Standard 1366-2012, are...
105