对半球共振器陀螺镜的相位延迟错误的识别和纠正
Youhuan Ning1, Changhong Wang1, Boqi Xi2
1Space Control and Inertial Technology Research Center, Harbin Institute of Technology, Harbin, 150080, Heilongjiang, China.
Scientific reports
|January 15, 2025
概括
这项研究引入了一种自我校准方法,以减少半球共振器陀螺仪 (HRGs) 的相延误. 该技术显著提高了陀螺仪在不同温度下的精度和稳定性.
科学领域:
- 惯性导航系统 惯性导航系统
- 传感器技术 传感器技术
- 精确度测量 精确度测量 精确度测量
背景情况:
- 阶段延迟错误是半球共振器陀螺仪 (HRGs) 输出错误的主要原因.
- 温度变化加剧了相延误误差,降低了陀螺仪的校准和性能.
研究的目的:
- 提出和验证一种自我校准方法,以减轻HRG中的相位延迟错误.
- 为了提高陀螺仪的现实应用性能和温度稳定性.
主要方法:
- 在整角模式HRG的正方位控制循环中引入一个正弦干扰信号.
- 调节了角速率信号以计算相位延迟误差.
- 使用计算错误作为相锁循环 (PLL) 参考阶段的补偿值.
主要成果:
- 自行校准将陀螺仪的零偏差输出误差降低了五倍.
- 自行校准方法实施后,偏差不稳定性提高了37.7%.
- 拟议的方法证明了对温度波动的强化稳定性.
结论:
- 开发的自我校准技术有效地抑制了HRG中的相延误误差.
- 这种方法显著提高了陀螺仪的精度,稳定性和温度弹性.
相关概念视频
Time and frequency -Domain Interpretation of Phase-lead Control
76
Phase-lead controllers are commonly used in various control systems to enhance response speed and stability. Adjusting the brightness on a television screen offers a practical example of phase-lead control. When contrast is enhanced, a phase-lead controller is employed. Mathematically, phase-lead control is identified when the first parameter is smaller than the second.
The design of phase-lead control involves the strategic placement of poles and zeros to balance steady-state error and system...
The design of phase-lead control involves the strategic placement of poles and zeros to balance steady-state error and system...
76
NMR Spectrometers: Resolution and Error Correction
658
When magnetic nuclei in a sample achieve resonance and undergo relaxation, the signal detected in NMR is an approximately exponential free induction decay. Fourier transform of an exponential decay yields a Lorentzian peak in the frequency domain. Lorentzian peaks in an NMR spectrum are defined by their amplitude, full width at half maximum, and position, where the peak width is governed by the spin-spin relaxation time alone. In real experiments, however, the applied magnetic field is rendered...
658
Adjusting a Traverse
48
In the site survey of a four-sided traverse, internal angles are essential to ensure geometric accuracy. The survey revealed that the sum of the measured internal angles was 359 degrees and 48 minutes, which is 12 minutes less than the expected 360 degrees. This discrepancy signals an error likely arising from measurement inaccuracies during the fieldwork.To rectify this error, the adjustment process involved distributing the 12-minute shortfall equally across the four internal angles. By...
48
Common Leveling Mistakes and Errors
59
A survey team is tasked with determining the elevation difference between points Point A and Point B, separated by uneven terrain. They use a leveling instrument and a leveling rod.Common MistakesMisreading the Rod: During a backsight reading at Point A, the instrumentman observes the rod partially obscured by tall grass. Instead of reading 1.135 m, they mistakenly record 1.735 m due to the misalignment of the crosshair with the wrong graduation. This error adds 0.600 m to all subsequent...
59
Time and frequency -Domain Interpretation of Phase-lag Control
84
Phase-lag controllers are widely used in control systems to improve stability and reduce steady-state errors. A dimmer switch controlling the brightness of a light bulb serves as a practical example of phase-lag control, gradually adjusting the bulb's brightness. Mathematically, phase-lag control or low-pass filtering is represented when the factor 'a' is less than 1.
Phase-lag controllers do not place a pole at zero, but instead influence the steady-state error by amplifying any...
Phase-lag controllers do not place a pole at zero, but instead influence the steady-state error by amplifying any...
84
Time and frequency -Domain Interpretation of PI Control
104
Proportional-Integral (PI) controllers are essential in many control systems to improve stability and performance. They are commonly used in everyday devices like thermostats to enhance system damping and reduce steady-state error. When the zero in the controller's transfer function is optimally placed, the system benefits significantly in terms of stability and accuracy.
Acting as a low-pass filter, the PI controller slows the system's response and extends settling times. This requires...
Acting as a low-pass filter, the PI controller slows the system's response and extends settling times. This requires...
104


