概括
一种新的间波封面校正方法 (IECM) 为吸收光谱学提供了无基线校正. 这种先进的技术在高压燃烧环境中准确测量压力,温度和H2O度.
科学领域:
- 燃烧诊断仪器的使用
- 频谱学是一种光谱学.
- 物理化学 物理化学
背景情况:
- 吸收光谱是燃烧分析的关键非接触方法.
- 水 (H2O) 通常用于温度测量.
- 高压扩大吸收光谱的基线校正存在重大挑战.
研究的目的:
- 引入一种新的算法,即交叉封装校正方法 (IECM),用于无基线校正.
- 为了使同时检索压力,温度和H2O度.
- 解决高温和高压燃烧诊断方面的局限性.
主要方法:
- 开发了插入式信封校正方法 (IECM).
- 计算测量频谱的下层包裹并减去它.
- 根据吸收光谱学原理应用最小正方形匹配.
主要成果:
- 与1273K和70bar.以下的背景多项式方法相比,IECM显示出更高的性能.
- 达到压力为1.49bar,温度为17K的根平均平方误差 (RMSE).
- 该方法有效地消除了光谱分析中的基线问题.
结论:
- IECM为宽带吸收频谱的基线校正提供了一个强大的解决方案.
- 它有助于在高压燃烧诊断中进行准确和方便的测量.
- 该方法提高了同时检索多个燃烧参数的可靠性.
更多相关视频
11:38In situ FTIR Spectroscopy as a Tool for Investigation of Gas/Solid Interaction: Water-Enhanced CO2 Adsorption in UiO-66 Metal-Organic Framework
Published on: February 1, 2020
15.8K
11:25Identification and Quantification of Decomposition Mechanisms in Lithium-Ion Batteries; Input to Heat Flow Simulation for Modeling Thermal Runaway
Published on: March 7, 2022
4.5K
相关概念视频
IR Spectrum Peak Broadening: Hydrogen Bonding
832
The vibrational frequency of a bond is directly proportional to its bond strength. As a result, stronger bonds vibrate at higher frequencies, while weaker bonds vibrate at lower frequencies. The stretching vibration of the strong O–H bond in alcohols and phenols (very dilute solution or gas phase) appears as a sharp peak at 3600–3650 cm−1.
However, the extent of hydrogen bonding influences the observed stretching frequency and band broadening. Intermolecular or intramolecular...
However, the extent of hydrogen bonding influences the observed stretching frequency and band broadening. Intermolecular or intramolecular...
832
Atomic Absorption Spectroscopy: Interference
649
Interference leads to systematic error in atomic absorption (AA) measurements by enhancing or diminishing the analytical signal or the background. These interferences can be grouped into three main categories: spectral interference, chemical interference, and physical interference.
Spectral interference occurs when signals from other elements or molecules overlap with the analyte signal, falsely elevating or masking the analyte's absorbance. This interference can be corrected using Zeeman,...
Spectral interference occurs when signals from other elements or molecules overlap with the analyte signal, falsely elevating or masking the analyte's absorbance. This interference can be corrected using Zeeman,...
649
UV–Vis Spectrometers
1.3K
The absorbance of UV and visible (UV–visible) radiations is measured using a UV–visible spectrophotometer. Deuterium lamps, which emit UV radiation, and tungsten lamps, which produce radiation in the visible region, are used as light sources in UV–visible spectrophotometers. A monochromator or prism is used for diffraction grating, i.e., to split the incoming radiation into different wavelengths. A system of slits is used to focus the desired wavelength on the sample cell.
1.3K
UV–Vis Spectrum
1.1K
When light passes through a substance, a portion of the light is absorbed while the remaining light is reflected or transmitted. If the molecule absorbs light between the wavelengths of 180–400 nm range, the UV spectrum is obtained, and if it absorbs light in the 400–780 nm wavelength range, the visible spectrum is obtained.
The UV–Vis spectrum of a molecule is the plot of its absorbance versus wavelength. The plot is drawn by taking molar...
The UV–Vis spectrum of a molecule is the plot of its absorbance versus wavelength. The plot is drawn by taking molar...
1.1K
UV–Vis Spectroscopy: Beer–Lambert Law
2.1K
The Beer-Lambert law describes the relationship between absorbance and concentration, which combines the principles established by scientists Johann Heinrich Lambert and August Beer. Lambert's law states that when light passes through a medium, the loss in intensity is directly proportional to the original intensity and the path length of the light. Beer's law proposed that the transmittance of a solution remains constant if the product of concentration and path length is constant. The...
2.1K
Atomic Absorption Spectroscopy: Overview
1.4K
Atomic absorption spectroscopy (AAS) is a technique used to analyze elements by measuring electromagnetic radiation (EMR) absorbed by atoms, which causes them to transition to a higher-energy orbit. The most crucial step in AAS is atomization, where the analyte is converted into gas-phase atoms, typically through a flame or furnace. Some of these atoms become thermally excited in the flame, while most remain in the ground state.
When irradiated by EMR of a particular wavelength, these...
When irradiated by EMR of a particular wavelength, these...
1.4K