一种建模技术,使用绕线结构来确定高频变压器泄漏电感度
Yasir S Dira1, Ahmad Q Ramli2, Ungku Anisa Ungku Amirulddin3
1Institute of Power Engineering, Universiti Tenaga Nasional, Kajang, 43000, Malaysia. yasirsabah291@gmail.com.
Scientific reports
|January 18, 2025
概括
这项研究通过调整绕位置来控制高频变压器 (HFT) 的泄漏感应,保持铜损耗. 新方法准确预测电感度,以提高转换器效率.
科学领域:
- 电气工程 电气工程
- 电力电子 电力电子 电力电子
- 变压器设计设计
背景情况:
- 高频变压器 (HFT) 的泄漏电感极大地影响了孤立的直流-直流转换器的性能.
- 转换器效率和控制策略,特别是双向隔离转换器 (BIDC) 和共振转换器,对泄漏感应值敏感.
研究的目的:
- 通过修改绕线配置,提出和验证一种新的方法来控制HFT中的泄漏电感度.
- 开发一个精确的数学模型,根据拟议的绕技术来预测泄漏电感.
主要方法:
- 通过调整初级和二级绕线之间的垂直分离来改变绕线配置.
- 开发一个修改后的数学模型,以准确计算泄漏电感.
- 通过模拟和实验测试在3P-BIDC中的三相HFT (3P-HFT) 上验证方法.
主要成果:
- 拟议的绕线配置方法成功控制了泄漏电感.
- 经过修改的数学模型在预测泄漏电感度方面表现出高准确度.
- 计算的感应率显示了与模拟的差异为3.9%,与实验结果的误差为4.53%.
结论:
- 卷轴配置调整是一种有效的技术,用于控制HFT泄漏电感.
- 开发的数学模型为精确的电感计算提供了可靠的工具.
- 这种方法提供了一种可行的方法来优化转换器性能,通过管理泄漏电感度而不会影响铜损耗.
更多相关视频
07:01Frequency Mixing Magnetic Detection Scanner for Imaging Magnetic Particles in Planar Samples
Published on: June 9, 2016
9.6K
06:45Design and Application of a Fault Detection Method Based on Adaptive Filters and Rotational Speed Estimation for an Electro-Hydrostatic Actuator
Published on: October 28, 2022
1.6K
相关概念视频
Equivalent Circuits for Practical Transformers
392
The practical equivalent circuits of single-phase two-winding transformers exhibit significant deviations from their idealized versions due to the inherent properties of winding resistance and finite core permeability. These properties result in real and reactive power losses, affecting the transformer's performance. Understanding these deviations is crucial for designing more efficient transformers.
In a practical transformer, each winding exhibits resistance and leakage reactance. The...
In a practical transformer, each winding exhibits resistance and leakage reactance. The...
392
Three-Winding Transformers
191
Three identical single-phase transformers can be configured to form a three-phase transformer connection, which involves high-voltage and low-voltage windings. The high-voltage windings are denoted by capital letters A-B-C, while the low-voltage windings are labeled with lowercase letters a-b-c, representing their respective phases. This notation helps distinguish between the high and low voltage sides of the transformer.
In the per-unit equivalent circuit of a grounded Y-Y three-phase...
In the per-unit equivalent circuit of a grounded Y-Y three-phase...
191
Energy Losses in Transformers
824
In an ideal transformer, it is assumed that there are no energy losses, and, hence, all the power at the primary winding is transferred to the secondary winding. However, in reality, the transformers always have some energy losses, and, hence, the output power obtained at the secondary winding is less than the input power at the primary winding due to energy losses.
There are four main reasons for energy losses in transformers.
The first cause can be the high resistance of the...
There are four main reasons for energy losses in transformers.
The first cause can be the high resistance of the...
824
Transformers
1.1K
A device that transforms voltages from one value to another using induction is called a transformer. A transformer consists of two separate coils, or windings, wrapped around the same soft iron core. However, they are electrically insulated from each other.
The iron core has a substantial relative permeability. Therefore, the magnetic field lines generated due to the current in one winding are almost entirely confined within the core, such that the same magnetic flux permeates each turn of both...
The iron core has a substantial relative permeability. Therefore, the magnetic field lines generated due to the current in one winding are almost entirely confined within the core, such that the same magnetic flux permeates each turn of both...
1.1K
The Ideal Transformer
352
In single-phase two-winding transformers, two windings are coiled around a magnetic core characterized by cross-sectional area A and magnetic permeability μ. A phasor current i1 enters the left winding while i2 exits the right winding, establishing the fundamental working of the transformer through electromagnetic principles.
Ampere's Law forms the basis of understanding the magnetic field within the transformer. It states that the integral of the magnetic field intensity's...
Ampere's Law forms the basis of understanding the magnetic field within the transformer. It states that the integral of the magnetic field intensity's...
352
Transformers with Off-Nominal Turns Ratios
138
In scenarios involving parallel transformers with disparate ratings, developing per-unit models requires accommodating off-nominal turns ratios. This situation arises when the selected base voltages are not proportional to the transformer’s voltage ratings. Consider a transformer where the rated voltages are related by the term a. If the chosen voltage bases satisfy a relationship involving term b, term c is defined as the ratio of these bases. This ratio is then substituted into the...
138