使用光学传感器对下肢生命体征的非侵入性监测
Joana Simões1, Regina Oliveira1, Florinda M Costa1
1Institute for Nanostructures, Nanomodelling and Nanofabrication (i3N), Department of Physics, University of Aveiro, 3810-193 Aveiro, Portugal.
Sensors (Basel, Switzerland)
|January 25, 2025
概括
这项研究开发了一种使用大腿佩戴传感器的新系统,用于持续的,无形的健康监测. 它准确地实时测量心率 (HR) 和呼吸率 (RR),证明了下肢生命体标志跟踪的可行性.
科学领域:
- 生物医学工程 生物医学工程
- 可穿戴技术可穿戴技术
- 健康监测 卫生监测
背景情况:
- 隐形的健康监测正在引起全球科学兴趣.
- 对日常物体进行传感可以在不改变用户日常工作的情况下持续收集健康数据.
研究的目的:
- 评估在下肢摄影 (PPG) 采集的可行性,以持续监测生命体征.
- 开发和验证一个实时心率 (HR) 和呼吸率 (RR) 测量系统,使用来自大腿的PPG信号.
主要方法:
- 利用两个MAX30102传感器放置在大腿的背部获取PPG信号.
- 对17名志愿者 (年龄22-40岁) 进行了概念验证研究.
- 将开发系统的测量与参考传感器进行了比较.
主要成果:
- 获得了Pearson相关系数,HR的r=0.92和RR的r=0.77.
- 与参考传感器相比,HR的平均差异为1.2bpm,RR的平均差异为0.9rpm.
- 证明了HR的系统准确率为95.9%,RR的系统准确率为91.3%.
结论:
- 开发的系统显示了在下肢的持续和实时生命体征监测显著的可行性.
- 这种方法提供了一种非侵入性的方法,通过日常物品的传感器来跟踪健康状况.
- 进一步的研究可以探索下肢PPG在远程患者监测方面的更广泛应用.
相关概念视频
Pulse rhythm
754
Pulse rhythm refers to the pattern of pulsations within specific intervals, offering valuable insights into the regularity or irregularity of the heart's beats as observed through the pattern of pulsation within specific intervals. A regular pulse exhibits a consistent heart rate with uniform waveforms and pulsation force, variations of which can be classified as normal, weak, or bounding.
Conversely, an irregular pulse pattern is termed dysrhythmia, stemming from disruptions in cardiac...
Conversely, an irregular pulse pattern is termed dysrhythmia, stemming from disruptions in cardiac...
754
Assessing Blood pressure in the Leg
1.9K
Proper measurement of leg blood pressure is a critical skill for healthcare providers, ensuring precise and reliable readings. When performed correctly, this procedure informs patient care and enhances the efficacy of interventions. The following text outlines step-by-step guidelines to measure blood pressure in the leg, providing clarity and ease of understanding for practitioners.
Preparation:
Preparation:
1.9K
Guidelines For Measuring Vital Signs
1.5K
Following these guidelines can help nurses accurately measure vital signs, assess changes in patient conditions, and provide timely treatment when necessary. Adhering closely to the guidelines ensures the accuracy and reliability of the results.
Before taking a patient's vital signs, a nurse would consider and assess the patient's comfort level and ensure appropriate equipment is available.
Before taking a patient's vital signs, a nurse would consider and assess the patient's comfort level and ensure appropriate equipment is available.
1.5K
Equipments Used To Measure Blood Pressure
816
Direct Method
This invasive approach involves cannulating a peripheral artery. During each cardiac contraction, pressure generates mechanical motion within the catheter, transmitted through rigid, fluid-filled tubing to a transducer. This transducer converts mechanical motion into electrical signals displayed as waveforms on a monitor. An automatic flushing system prevents blood backflow. Due to the potential risk of unexpected arterial blood loss, this method is primarily used in intensive...
This invasive approach involves cannulating a peripheral artery. During each cardiac contraction, pressure generates mechanical motion within the catheter, transmitted through rigid, fluid-filled tubing to a transducer. This transducer converts mechanical motion into electrical signals displayed as waveforms on a monitor. An automatic flushing system prevents blood backflow. Due to the potential risk of unexpected arterial blood loss, this method is primarily used in intensive...
816
Pulse Assessment Sites
914
Pulse assessment sites are crucial in evaluating a patient's cardiovascular health. By assessing the pulsations of arteries at specific anatomical locations, healthcare professionals can gather valuable information about blood flow, heart rate, and peripheral circulation. Understanding these pulse assessment sites is essential for conducting comprehensive cardiovascular evaluations and monitoring patients' overall health. These sites are strategically chosen due to the accessibility and...
914
Assessing Blood pressure using a doppler ultrasound
1.2K
To obtain accurate blood pressure measurements in clinical settings, especially when traditional methods are insufficient, healthcare professionals utilize the Doppler ultrasound technique. This method uses high-frequency sound waves to detect blood flow within the arteries, which is crucial for patients with conditions that complicate circulatory system assessment.
Pre-Procedural Guidelines for Doppler Ultrasound Blood Pressure Assessment:
Preparation of Equipment:
Pre-Procedural Guidelines for Doppler Ultrasound Blood Pressure Assessment:
Preparation of Equipment:
1.2K