一种非侵入性微循环监测的新方法:使用氧度脉冲波量化毛细血管补充时间
Yuxiang Xia1, Xinrui Wang1, Zhe Guo2
1School of Clinical Medicine, Tsinghua University, 30 Shuangqing Road, Haidian District Beijing, Beijing 102218, China.
Sensors (Basel, Switzerland)
|January 25, 2025
概括
开发了一种新的毛细血管补充时间 (CRT) 测量系统,显示可靠和可重复的结果. 这种非侵入性设备提供快速的微循环监测,实现高医生和患者的满意度.
科学领域:
- 生物医学工程 生物医学工程
- 医疗器械 医疗器械
- 微循环研究 微循环研究
背景情况:
- 毛细血管补充时间 (CRT) 是外周循环的临床指标.
- 现有的CRT测量方法可能是主观的,耗时的.
- 需要一个可靠和客观的系统来测量CRT.
研究的目的:
- 开发和评估一种用于测量毛细血管补充时间的新系统.
- 评估开发的CRT测量系统的可靠性和可重复性.
- 调查新设备的临床可行性和用户满意度.
主要方法:
- 利用电磁压力技术,自动压缩和释放手指.
- 采用压力传感和光电体积脉冲波分析用于动态血流监测.
- 对71名受试者进行了研究,以评估测量时间,所需的测量,一致性 (A组) 和可重复性 (B组).
- 通过问卷收集医生和患者满意度数据.
主要成果:
- 成功开发了一种毛细血管补充时间计,每次测量平均测量时间为18秒.
- 实现了高满意度:医生98.3%,患者100%.
- 在A组中表现出极好的一致性,A组的类内相关系数为0.995,B组的可重复性显著 (p > 0.05).
结论:
- 开发的系统提供了快速有效的微循环的非侵入性监测.
- 毛细管补充时间计测试机产生一致和可重复的CRT测量结果.
- 该设备支持微循环评估的机械化和标准化.
相关概念视频
Pulse Oximetry
308
Pulse oximetry, or SpO2, is a non-invasive method for continuously monitoring arterial oxygen saturation (SaO2). This procedure involves attaching a probe or sensor to the patient's fingertip, forehead, earlobe, or nose bridge. The sensor works by detecting changes in oxygen saturation levels through light signals generated by the oximeter and reflected by the pulsing blood under the probe.
Purpose
Average SpO2 values are greater than 95%. If the readings fall below 90%, it indicates that...
Purpose
Average SpO2 values are greater than 95%. If the readings fall below 90%, it indicates that...
308
Pulse rhythm
754
Pulse rhythm refers to the pattern of pulsations within specific intervals, offering valuable insights into the regularity or irregularity of the heart's beats as observed through the pattern of pulsation within specific intervals. A regular pulse exhibits a consistent heart rate with uniform waveforms and pulsation force, variations of which can be classified as normal, weak, or bounding.
Conversely, an irregular pulse pattern is termed dysrhythmia, stemming from disruptions in cardiac...
Conversely, an irregular pulse pattern is termed dysrhythmia, stemming from disruptions in cardiac...
754
Pulse
428
When the heart pumps blood out, arterial elastic fibers play a crucial role in sustaining a high-pressure gradient. They expand to accommodate the received blood and then recoil - a process known as the pulse that can be either manually palpated or electronically quantified. Despite a reduction in its effect with increased distance from the heart, elements of the pulse's systolic and diastolic components persist, observable even at the arteriole level.
The pulse serves as a clinical...
The pulse serves as a clinical...
428
Special considerations while measuring pulse
555
Assessing a patient's pulse is a fundamental skill in healthcare, but certain situations require special attention:
555
Guidelines For Measuring Vital Signs
1.5K
Following these guidelines can help nurses accurately measure vital signs, assess changes in patient conditions, and provide timely treatment when necessary. Adhering closely to the guidelines ensures the accuracy and reliability of the results.
Before taking a patient's vital signs, a nurse would consider and assess the patient's comfort level and ensure appropriate equipment is available.
Before taking a patient's vital signs, a nurse would consider and assess the patient's comfort level and ensure appropriate equipment is available.
1.5K
Pulse Assessment Sites
914
Pulse assessment sites are crucial in evaluating a patient's cardiovascular health. By assessing the pulsations of arteries at specific anatomical locations, healthcare professionals can gather valuable information about blood flow, heart rate, and peripheral circulation. Understanding these pulse assessment sites is essential for conducting comprehensive cardiovascular evaluations and monitoring patients' overall health. These sites are strategically chosen due to the accessibility and...
914