相关实验视频
Updated: May 30, 2025

08:14
Ammonia Synthesis at Low Pressure
Published on: August 23, 2017
26.4K
学习,规模经济和知识差距对发电技术成本改善的影响
Yoga W Pratama1, Matthew J Gidden1, Jenna Greene2
1International Institute for Applied Systems Analysis, Laxenburg, Lower Austria, Austria.
iScience
|January 27, 2025
概括
规模经济显著推动了清洁技术成本的降低,比传统的学习模式所暗示的要多. 将这些因素分开可以改善成本估计和清洁技术部署策略.
科学领域:
- 能源经济学 能源经济学
- 技术管理 技术管理
- 环境科学 环境科学
背景情况:
- 清洁技术的部署对于可持续性至关重要.
- 传统的成本降低模式往往依赖于单一的因素,如累计的装机容量.
- 过于简单的模型可能会误解成本下降的真正驱动因素.
研究的目的:
- 解开学习和规模经济对技术成本的影响.
- 引入知识差距概念来量化快速的技术变化.
- 为清洁技术提供更准确的成本估计.
主要方法:
- 分析单位和项目级成本数据.
- 学习曲线和规模经济的分离.
- 引入和应用一个知识差距指标.
主要成果:
- 规模经济是许多技术成本下降的重要驱动因素.
- 学习过程在降低成本方面所占的比例比以前假设的要小.
- 知识差距概念有效地捕捉了技术的演变.
结论:
- 一因素学习模型可以不准确地预测成本下降.
- 区分学习和规模经济对于准确的技术成本预测至关重要.
- 改进的成本估计可以提高清洁技术部署决策.
相关概念视频
Power Factor Correction
155
The power transmission to a factory involves the transfer of apparent power, a combination of active and reactive power. The power factor measures how effectively electrical power is converted into useful work output. The ratio of the real power (KW) that does the work to the apparent power (KVA) supplied to the circuit.
155
Control of Power Flow
250
There are several methods to control power flow in power systems:
250
Reducing Line Loss
143
In a three-phase circuit, line loss is an indicator of energy dissipated as heat due to the resistance of transmission lines. To address this, incorporating transformers into the system—a step-up transformer at the source and a step-down transformer at the load—is a strategic solution. Two three-phase transformers are introduced to improve this.
With a step-up transformer at the source, the voltage is increased, thereby reducing the current in the transmission lines since power loss...
With a step-up transformer at the source, the voltage is increased, thereby reducing the current in the transmission lines since power loss...
143
Energy Losses in Transformers
823
In an ideal transformer, it is assumed that there are no energy losses, and, hence, all the power at the primary winding is transferred to the secondary winding. However, in reality, the transformers always have some energy losses, and, hence, the output power obtained at the secondary winding is less than the input power at the primary winding due to energy losses.
There are four main reasons for energy losses in transformers.
The first cause can be the high resistance of the...
There are four main reasons for energy losses in transformers.
The first cause can be the high resistance of the...
823
Fast Decoupled and DC Powerflow
164
The fast decoupled power flow method addresses contingencies in power system operations, such as generator outages or transmission line failures. This method provides quick power flow solutions, essential for real-time system adjustments. Fast decoupled power flow algorithms simplify the Jacobian matrix by neglecting certain elements, leading to two sets of decoupled equations:
164
Load-frequency control
117
Load-frequency control (LFC) is vital for maintaining power system stability, ensuring that frequency and power flows remain within acceptable limits during load changes. Turbine-governor control eliminates rotor accelerations and decelerations following load changes. However, a steady-state frequency error persists when the change in the turbine-governor reference setting is zero. In an interconnected power system, each area agrees to export or import a scheduled amount of power through...
117

