通过光学连贯性断层扫描高精度,非侵入性地测量骨顶水平
Wei-Ting Chang1,2, Dong-Yuan Lyu1, Yu-Lin Lai1,2
1School of Dentistry, National Yang Ming Chiao Tung University, Taipei, Taiwan.
Journal of dental sciences
|January 28, 2025
概括
光学连贯断层扫描 (OCT) 可以准确地测量脊骨水平 (CBL) 非侵入性,即使有牙存在. 这项技术显示出改善牙科诊断和牙周标志识别的潜力.
科学领域:
- 生物医学光学 生物医学光学
- 牙周病学 牙周病学
- 牙科成像 牙科成像 牙科成像
背景情况:
- 传统的牙科放射图很难在口腔和语言方面准确地确定骨水平 (CBL).
- 光学连贯断层扫描 (OCT) 提供了牙周组织的非侵入性,深入的可视化.
研究的目的:
- 评价海外国家和地区在识别牙周标志方面的有效性.
- 评估海外国家和地区在牙周存在的情况下测量CBL的能力.
主要方法:
- 使用了手持式扫描源OCT (SS-OCT) 系统和自定义算法.
- 在使用人工牙的牙科模型中测量了CBL,将SS-OCT与2.5D检查系统进行比较.
主要成果:
- 在SS-OCT和2.5D之间的CBL测量的平均差异是最小的 (0.008毫米).
- 在各种牙尺寸或牙厚度之间没有发现显著的测量差异.
结论:
- 该SS-OCT系统通过人工牙准确而非侵入性地评估CBL.
- 该系统有助于半自动划分牙周地标,表明临床潜力.
相关概念视频
Computed Tomography
4.2K
Tomography refers to imaging by sections. Computed tomography (CT) is a non-invasive imaging technique that uses computers to analyze several cross-sectional X-rays to reveal minute details about structures in the body.
The technique was invented in the 1970s and is based on the principle that as X-rays pass through the body, they are absorbed or reflected at different levels. In the technique, a patient lies on a motorized platform while a computerized axial tomography (CAT) scanner rotates...
The technique was invented in the 1970s and is based on the principle that as X-rays pass through the body, they are absorbed or reflected at different levels. In the technique, a patient lies on a motorized platform while a computerized axial tomography (CAT) scanner rotates...
4.2K
Differential Leveling
132
Differential leveling is a precise method in surveying used to determine the elevation difference between two points. Its primary goal is to establish accurate vertical measurements to create level surfaces or grade lines critical for designing and constructing infrastructures such as roads, bridges, and buildings.The procedure for differential leveling begins with setting up and leveling the instrument at a point where the benchmark can be seen. The level rod is held on the benchmark (BM), and...
132
Pulse Oximetry
308
Pulse oximetry, or SpO2, is a non-invasive method for continuously monitoring arterial oxygen saturation (SaO2). This procedure involves attaching a probe or sensor to the patient's fingertip, forehead, earlobe, or nose bridge. The sensor works by detecting changes in oxygen saturation levels through light signals generated by the oximeter and reflected by the pulsing blood under the probe.
Purpose
Average SpO2 values are greater than 95%. If the readings fall below 90%, it indicates that...
Purpose
Average SpO2 values are greater than 95%. If the readings fall below 90%, it indicates that...
308