对无刷直流电机和开关不情愿电机进行比较分析,以优化离网抽水
Avinash Kumar1, Sanjay Marwaha1, Manpreet Singh Manna1
1Department of EIE, SLIET, Longowal, India.
Scientific reports
|January 28, 2025
概括
无刷直流电机 (BLDC) 与开关阻抗电机 (SRM) 相比,为离网水系统提供更高的扭矩和更顺的运行. 这项研究验证了BLDC和SRM在可持续能源解决方案方面的表现.
科学领域:
- 电气工程 电气工程
- 可再生能源系统可再生能源系统
- 可持续技术 可持续技术
背景情况:
- 离网抽水系统 (OGWPS) 对于可持续的能源解决方案至关重要.
- 无刷直流 (BLDC) 和开关阻力电机 (SRM) 是低功率应用的可行选择.
- 在OGWPS中对电机性能进行比较分析对于优化效率至关重要.
研究的目的:
- 使用有限元法 (FEM) 设计和分析OGWPS的BLDC和SRM.
- 在相同的条件下比较BLDC和SRM的性能特征,包括扭矩和效率.
- 评估BLDC和SRM技术是否适用于提高OGWPS的效率和可靠性.
主要方法:
- 使用适应性有限元分析 (FEA) 进行NEMA 42标准几何形状的电机设计.
- 实现了SRM的 (n+1) 开关转换器和用于BLDC的三相电压源逆变器 (VSI) 的Cuk转换器.
- 在相同的操作条件下对扭矩配置,效率和扭矩波动进行了比较分析.
主要成果:
- BLDC电机实现了11.5Nm的最大扭矩和91.9%的效率.
- 在SRM中,最大扭矩为3.8Nm,效率为94.6%.
- 与SRM (1.19 pu) 相比,BLDC电机的扭矩波动较低 (0.73 pu),这表明操作更顺.
结论:
- 对于OGWPS,BLDC电机在扭矩和运行顺方面表现出卓越的性能.
- 对于OGWPS来说,BLDC和SRM技术都是可行的,BLDC在特定性能指标方面提供了优势.
- 模拟结果通过对原型电机的实验测试来验证.
更多相关视频
09:04A Modeling and Simulation Method for Preliminary Design of an Electro-Variable Displacement Pump
Published on: June 1, 2022
3.0K
06:45Design and Application of a Fault Detection Method Based on Adaptive Filters and Rotational Speed Estimation for an Electro-Hydrostatic Actuator
Published on: October 28, 2022
1.6K
相关概念视频
Electro-mechanical Systems
914
Electromechanical systems are intricate configurations that effectively combine electrical and mechanical elements to achieve a desired outcome. Central to many of these systems is the DC motor, a device that converts electrical energy into mechanical motion, enabling various applications ranging from simple fans to complex robotic mechanisms.
A key component of the DC motor is the armature, a rotating circuit positioned within a magnetic field. As an electric current passes through the...
A key component of the DC motor is the armature, a rotating circuit positioned within a magnetic field. As an electric current passes through the...
914
Force On A Current Loop In A Magnetic Field
3.2K
Magnetic forces on wires carrying current are most frequently applied in motors. A DC motor is a device that converts electrical energy into mechanical work. In motors, wire loops are enclosed in a magnetic field. When current flows through the loops, the magnetic field applies torque, which causes the shaft to rotate. The direction of the current is reversed once the loop's surface area is lined up with the magnetic field, causing a constant torque on the loop. During the process,...
3.2K
Back EMF
2.7K
Generators convert mechanical energy into electrical energy, whereas motors convert electrical energy into mechanical energy. A motor works by sending a current through a loop of wire located in a magnetic field. As a result, the magnetic field exerts a torque on the loop. This rotates a shaft, extracting mechanical work from the electrical current sent in initially. When the coil of a motor is turned, magnetic flux changes through the coil, and an emf (consistent with Faraday's law) is...
2.7K
DC Generator
658
An alternator converts mechanical energy into electrical energy that varies sinusoidally, resulting in AC current. Meanwhile, a DC generator converts mechanical energy into electrical energy, which are DC pulses with the same polarity. The construction of a DC generator is similar to that of an alternator, except that the pair of slip rings is replaced by a single split ring, also called a commutator. The commutator functions like a periodic rotary switch; it changes the contacts with the...
658
Fast Decoupled and DC Powerflow
164
The fast decoupled power flow method addresses contingencies in power system operations, such as generator outages or transmission line failures. This method provides quick power flow solutions, essential for real-time system adjustments. Fast decoupled power flow algorithms simplify the Jacobian matrix by neglecting certain elements, leading to two sets of decoupled equations:
164
Wind Turbine Machine Models
98
In the growing field of wind energy, incorporating wind turbine models into transient stability analysis is essential. Induction and synchronous machines are the primary models used, with induction machines being prevalent due to their simplicity and reliability.
Induction machines interact through the rotating magnetic field generated by the stator and the rotor. The key parameter is slip, which is the difference between synchronous speed and rotor speed relative to synchronous speed. Slip is...
Induction machines interact through the rotating magnetic field generated by the stator and the rotor. The key parameter is slip, which is the difference between synchronous speed and rotor speed relative to synchronous speed. Slip is...
98