概括
太赫兹时域光谱和极度测量通过分析太赫兹波极化来诊断等离子体参数. 感应合等离子体显示出作为可调节的太赫兹调制器的潜力.
科学领域:
- 血物理学的等离子体物理学
- 光学诊断仪器的使用.
- 太赫兹技术是太赫兹技术.
背景情况:
- 太赫兹时域光谱 (THz-TDS) 是用于等离子体诊断的非侵入性光学方法.
- 现有的研究主要检查THz波的相位和振幅变化,忽视极化特征.
研究的目的:
- 为了研究由电感应合等离子体 (ICP) 诱导的太赫兹极化旋转角度.
- 扩展太赫兹技术的功能,用于全面的等离子体诊断.
主要方法:
- 使用太赫兹时域极度测量 (THz-TDP) 与THz-TDS.
- 在ICP中测量极化旋转角度.
- 分析了太赫兹发射率和等离子电子密度.
主要成果:
- 使用THz-TDP成功诊断出血参数,包括偏振旋转.
- 观察到阿贡ICP诱导了显著的太赫兹极化旋转.
- 展示了ICP作为可调节的太赫兹调制器的潜力.
结论:
- 特拉赫兹时域极度测量增强了血诊断能力.
- 阿贡ICP表现出适用于可调节的太赫兹调制应用的性能.
相关概念视频
Potential Due to a Polarized Object
358
A neutral atom consists of a positively charged nucleus surrounded by a negatively charged electron cloud. When placed in an external electric field, the external electric force pulls the electrons and nucleus apart, opposite to the intrinsic attraction between the nucleus and the electrons. The opposing forces balance each other with a slight shift between the center of masses of the nucleus and the electron cloud, resulting in a polarized atom. On the other hand, a few molecules, like water,...
358
Dielectric Polarization in a Capacitor
4.6K
The presence of a dielectric medium in a capacitor not only changes the voltage and capacitance but also affects the electric field. In general, dielectrics can be of two types: polar and nonpolar. In a polar dielectric, the positive and negative charges in the molecules are separated by a distance and hence have a permanent dipole moment. In contrast, no such charge separation exists in a nonpolar dielectric, however the nonpolar molecules get polarized in the presence of an external electric...
4.6K
Susceptibility, Permittivity and Dielectric Constant
1.4K
When placed in an external electric field, a dielectric material gets polarized. The charge density in the dielectric material is given by the sum of the bound and free charge densities, while the total charge density can also be written in terms of the total electric field. The bound charge density can be measured in terms of polarization, leading to the relationship between electric displacement and polarization.
1.4K
Inductively Coupled Plasma Atomic Emission Spectroscopy: Principle
502
Inductively coupled plasma (ICP) is the most widely used plasma source in atomic emission spectroscopy (AES), also known as Inductively Coupled Plasma Optical Emission Spectroscopy (ICP-OES). The ICP source, or torch, consists of three concentric quartz tubes with argon gas flowing through them. A spark from a Tesla coil initiates the ionization of argon, generating a high-temperature plasma.
The ions and electrons produced interact with the fluctuating magnetic field created by a water-cooled...
The ions and electrons produced interact with the fluctuating magnetic field created by a water-cooled...
502
π Electron Effects on Chemical Shift: Overview
1.0K
An applied magnetic field causes loosely bound π-electrons in organic molecules to circulate, producing a local or induced diamagnetic field over a large spatial volume. As the molecules tumble in solution, the field generated by π-electrons in spherical substituents results in a zero net field. However, the net field generated by π-electrons in non-spherical substituents is not zero. The effect of this induced field depends on the orientation of the molecule with respect to B0,...
1.0K
¹³C NMR: Distortionless Enhancement by Polarization Transfer (DEPT)
1.0K
When proton-coupled carbon-13 spectra are simplified by a broadband proton decoupling technique, structural information about the coupled protons is lost. Distortionless enhancement by polarization transfer (DEPT) is a technique that provides information on the number of hydrogens attached to each carbon in a molecule. While the DEPT experiment utilizes complex pulse sequences, the pulse delay and flip angle are specifically manipulated. The resulting signals have different phases depending on...
1.0K