通过智能手机发出的声波来使用子宫内压力进行分娩诊断
Benjamin Alderson1, A Osman2, Mahmoud Ahmed El-Sayed3
1School of Engineering, University of Birmingham, Edgbaston, B15 2TT, UK.
Medical & biological engineering & computing
|January 31, 2025
概括
通过使用智能手机发射的声音波来改善诊断分娩开始. 这项研究表明,在3D模型中,声波反射和内部腹部压力之间存在正相关性.
科学领域:
- 产科和妇科 产科和妇科
- 生物医学工程 生物医学工程
- 声学物理 声学物理
背景情况:
- 准确诊断分娩开始仍然是产科的一个重大挑战.
- 目前的诊断方法通常很昂贵,需要专门的医疗保健专业人员.
- 需要一种具有成本效益,可访问和非侵入性的劳动力评估方法.
研究的目的:
- 调查使用智能手机发射的声波来评估内部腹部压力的可行性.
- 在模拟怀孕模型中确定声反射系数和腹内压力之间的关系.
- 为了确定最佳的声频,用于非侵入性压力测量.
主要方法:
- 使用一个40周怀孕的腹部的3D打印尺度模型.
- 该模型用水膨胀,以模拟腹内压力.
- 从智能手机在不同距离发射4kHz和20kHz的声波,并测量反射系数.
主要成果:
- 在反射系数和内部压力之间观察到正线性相关性.
- 反射系数在距离减少时平稳,表明材料和.
- 与4kHz相比,20kHz频率显示出较少的误差和无声特性.
结论:
- 基于智能手机的声学分析显示了评估腹腔内压力的实际潜力.
- 20kHz频率被提出为准确,无痛和长时间的劳动监测的最佳选择.
- 这种非侵入性技术可以在产科中提供更容易获得的诊断工具.
相关概念视频
Assessing Blood pressure using a doppler ultrasound
1.2K
To obtain accurate blood pressure measurements in clinical settings, especially when traditional methods are insufficient, healthcare professionals utilize the Doppler ultrasound technique. This method uses high-frequency sound waves to detect blood flow within the arteries, which is crucial for patients with conditions that complicate circulatory system assessment.
Pre-Procedural Guidelines for Doppler Ultrasound Blood Pressure Assessment:
Preparation of Equipment:
Pre-Procedural Guidelines for Doppler Ultrasound Blood Pressure Assessment:
Preparation of Equipment:
1.2K
Ultrasonography
4.3K
Ultrasonography is an imaging technique that uses high-frequency sound waves to visualize the body's internal structures. It is a non-invasive and safe procedure that does not involve the use of ionizing radiation, making it widely used in various medical fields. Ultrasonography is used to study heart function, blood flow in the neck or extremities, certain conditions such as gallbladder disease, and fetal growth and development.
During an ultrasonography procedure, a handheld device called...
During an ultrasonography procedure, a handheld device called...
4.3K
Equipments Used To Measure Blood Pressure
802
Direct Method
This invasive approach involves cannulating a peripheral artery. During each cardiac contraction, pressure generates mechanical motion within the catheter, transmitted through rigid, fluid-filled tubing to a transducer. This transducer converts mechanical motion into electrical signals displayed as waveforms on a monitor. An automatic flushing system prevents blood backflow. Due to the potential risk of unexpected arterial blood loss, this method is primarily used in intensive...
This invasive approach involves cannulating a peripheral artery. During each cardiac contraction, pressure generates mechanical motion within the catheter, transmitted through rigid, fluid-filled tubing to a transducer. This transducer converts mechanical motion into electrical signals displayed as waveforms on a monitor. An automatic flushing system prevents blood backflow. Due to the potential risk of unexpected arterial blood loss, this method is primarily used in intensive...
802