评估压缩对改善年轻志愿者的动脉合规性的急性影响
Kosuke Morinaga1,2, Masako Nakahara3, Kotaro Matsuura1
1Graduate School of System Cybernetics, Hiroshima University, Higashi-Hiroshima, Japan.
Heliyon
|February 3, 2025
概括
佩戴压缩可显著降低臂脚脉冲波速率 (ba-PWV),改善动脉合规性. 这项研究表明,压缩通过施加外部压力来增强动脉功能.
科学领域:
- 血管生理学 血管生理学
- 生物医学工程 生物医学工程
背景情况:
- 已知压缩子可以改善静脉回流.
- 它们对动脉功能的影响,特别是脉冲波速度,以前没有研究过.
研究的目的:
- 为了研究佩戴压缩对腕脉冲波速 (ba-PWV) 的影响.
- 为了确定压缩是否会影响动脉遵守.
主要方法:
- 一项涉及106名参与者的比较研究测量了ba-PWV.
- 在三个条件下进行测量:赤脚,普通子和压缩子.
- 平均动脉压 (MAP) 被记录下来,以估计动脉壁上的子压力.
主要成果:
- 与赤脚和普通相比,压缩显著减少了ba-PWV (p < 0.0001).
- 平均ba-PWV在右侧和左侧与压缩子下降约6%.
- 在ba-PWV和压缩所施加的估计压力之间发现了负相关性.
结论:
- 佩戴压缩有效地减少了ba-PWV.
- 这种减少表明由于子施加的外部压力而改善了动脉遵守.
- 压缩子积极影响下肢动脉功能.
相关概念视频
Assessing Blood pressure in the Leg
1.9K
Proper measurement of leg blood pressure is a critical skill for healthcare providers, ensuring precise and reliable readings. When performed correctly, this procedure informs patient care and enhances the efficacy of interventions. The following text outlines step-by-step guidelines to measure blood pressure in the leg, providing clarity and ease of understanding for practitioners.
Preparation:
Preparation:
1.9K
Sites for measruring blood pressure
1.4K
Blood pressure measurement is a fundamental clinical procedure, providing crucial data for assessing cardiovascular health. Among the various sites for this measurement, the brachial and popliteal arteries are predominantly utilized due to their accessibility and the reliability of their readings. This lesson delves into the anatomical significance, methodology, and considerations of measuring blood pressure at these locations.
The Brachial Artery: Primary Site for Blood Pressure Measurement
The Brachial Artery: Primary Site for Blood Pressure Measurement
1.4K
Assessment of blood pressure in brachial artery(two-step method)
648
Measuring blood pressure is a fundamental skill in healthcare that aids in diagnosing and monitoring hypertension and other cardiovascular conditions. An aneroid sphygmomanometer, commonly used in clinical settings, offers a manual and precise method for blood pressure measurement. The technique for using this instrument involves specific steps that must be carefully executed to ensure accuracy. The following detailed description outlines a two-step technique for assessing blood pressure using...
648
Arteries of Lower Limbs
1.1K
The external iliac artery transitions out of the body cavity, entering the femoral region of the lower leg, and is renamed the femoral artery at the point where it traverses the body wall. This artery is responsible for the distribution of blood to the thigh's deep muscles and the skin's ventral and lateral regions, achieved through several minor branches and the lateral deep femoral artery, which also spawns a lateral circumflex artery. The knee area receives blood from the genicular...
1.1K
Assessment of the Cardiovascular System III: Palpation
176
Palpation involves feeling the body to evaluate texture, size, consistency, and tenderness for assessing cardiovascular health. The following steps are organized in a head-to-toe order:
Jugular Venous Pressure (JVP) Measurement
Position the patient at a thirty- to forty-five-degree angle or in a semi-fowler's position. Look for the highest point of pulsation in the internal jugular vein and measure the vertical distance to the angle of Loius or sternal angle. A normal JVP is 3-4 cm above...
Jugular Venous Pressure (JVP) Measurement
Position the patient at a thirty- to forty-five-degree angle or in a semi-fowler's position. Look for the highest point of pulsation in the internal jugular vein and measure the vertical distance to the angle of Loius or sternal angle. A normal JVP is 3-4 cm above...
176
Arteries of the Lower Limbs
177
Epilepsy is a chronic neurological disease marked by recurrent, unpredictable seizures. These seizures are caused by abnormal electrical discharges in the brain, leading to behavior, sensation, or consciousness alterations. They can also cause transient impairment of awareness, interfering with daily activities.
Various factors can trigger epilepsy, including genetic factors, brain damage, metabolic causes, and unknown etiology. Diagnosis of epilepsy involves electroencephalography (EEG), which...
Various factors can trigger epilepsy, including genetic factors, brain damage, metabolic causes, and unknown etiology. Diagnosis of epilepsy involves electroencephalography (EEG), which...
177


