国际海事组织vifa24plus (((1-2) 和汉弗里场分析仪24-2-2的比较
Yuki Takagi1,2, Ryo Asano1,3, Kanna Yamashita2
1Department of Ophthalmology, Japan Community Healthcare Organization Chukyo Hospital, Nagoya, Aichi, Japan.
Clinical ophthalmology (Auckland, N.Z.)
|February 4, 2025
概括
与HFA 24-2相比,IMO vifa 24plus(1-2) 视野测试速度更快,并显示了更好的固定. 这两种测试都显示了对青光眼诊断的高度相关性.
科学领域:
- 眼科医生 眼科 眼科
- 医疗技术 医疗技术 医学技术
- 诊断成像 诊断成像 诊断成像
背景情况:
- 青光眼的诊断依赖于准确的视野测试.
- 传统的汉弗里场分析仪 (HFA) 24-2是标准的,但可能耗时.
- 像IMO vifa 24plus ((1-2) 这样的新设备旨在提高效率和准确性.
研究的目的:
- 为了比较IMO vifa 24plus (((1-2) 和HFA 24-2视野测试在青光眼患者中的性能.
- 为了评估测试时间,固定精度和诊断参数的差异.
主要方法:
- 52名青光眼患者 (104只眼睛) 在同一天接受了HFA 24-2 (SITA标准) 和IMO vifa 24plus (AIZE) 测试.
- 统计分析包括威尔科克森的签名等级测试和斯皮尔曼的等级相关系数.
- 关键指标:测试时间,固定错误,假阳性/假阴性,视野指数 (VFI),平均偏差 (MD) 和模式标准偏差 (PSD).
主要成果:
- 国际海事组织vifa 24plus(1-2) 测试时间显著缩短 (628.75s vs 716.83s,P<0.001).
- 固定精度显著提高,使用IMOvifa 24plus(1-2) (11.09%对比15.85%,P<0.0001).
- 在MD (0.938),PSD (0.949) 和VFI (0.932) 中观察到HFA 24-2和IMO vifa 24plus(1-2之间的高相关性,所有P<0.001.
结论:
- 国际海事组织的vifa 24plus ((1-2) 提供了一个更快,更有效的视觉现场测试,用于玻璃眼患者.
- 它的诊断准确度与HFA 24-2的诊断准确度相提并论,并具有更好的固定性.
- 这表明IMO vifa 24plus ((1-2) 是对玻璃眼视野评估的一个可行的替代方案.
相关概念视频
Mass Analyzers: Common Types
550
The quadrupole mass analyzer consists of four cylindrical metal rods arranged in a diamond carrying a DC voltage and a radio-frequency AC voltage. The motion of ions through the quadrupole depends on the field strength, causing only ions of a certain m/z to resonate successfully and strike the detector at a given field strength. Though the transmission rate for these analyzers is high, the exact elemental composition of the sample is not determined because of low resolution; however, they are...
550
UV–Vis Spectrometers
1.3K
The absorbance of UV and visible (UV–visible) radiations is measured using a UV–visible spectrophotometer. Deuterium lamps, which emit UV radiation, and tungsten lamps, which produce radiation in the visible region, are used as light sources in UV–visible spectrophotometers. A monochromator or prism is used for diffraction grating, i.e., to split the incoming radiation into different wavelengths. A system of slits is used to focus the desired wavelength on the sample cell.
1.3K
IR Spectrometers
1.1K
There are two main infrared (IR) spectrophotometers: dispersive IR spectrometers and Fourier transform infrared (FTIR) spectrometers. In a dispersive IR spectrometer, a beam of infrared radiation produced by a hot wire is divided into two parallel equal-intensity beams using mirrors. One beam passes through the sample, while another is a reference beam. The beams then move through the monochromator, which separates the radiations into a continuous spectrum of different frequencies. The...
1.1K
Inductively Coupled Plasma Atomic Emission Spectroscopy: Instrumentation
184
Inductively coupled plasma (ICP) is the common plasma source used in atomic emission spectroscopy (AES), a technique that detects and analyzes various elements in a sample. This method is often called inductively coupled plasma atomic emission spectroscopy (ICP-AES).
There are three main types of inductively coupled plasma atomic emission spectroscopy (ICP-AES) instruments: sequential, simultaneous multichannel, and Fourier transform instruments, with the latter being less commonly used....
There are three main types of inductively coupled plasma atomic emission spectroscopy (ICP-AES) instruments: sequential, simultaneous multichannel, and Fourier transform instruments, with the latter being less commonly used....
184
Mass Analyzers: Overview
569
The mass analyzer is a crucial component of the mass spectrometer. In the ionization chamber, the vaporized sample is bombarded with a high-energy electron beam to generate a radical cation and further fragment into neutral molecules, radicals, and cations. A series of negatively charged accelerator plates accelerate the cations into the mass analyzer. The mass analyzer separates ions according to their mass-to-charge (m/z) ratios and then directs them to the detector. The common types of mass...
569
Fluorescence and Phosphorescence: Instrumentation
529
Fluorometers and spectrofluorometers are two types of instruments used for measuring molecular fluorescence. These instruments differ in how they select excitation and emission wavelengths and the type of light sources they utilize. Fluorometers use absorption interference filters to choose excitation and emission wavelengths. The excitation source in a fluorometer is typically a low-pressure mercury vapor lamp that emits intense lines distributed throughout the ultraviolet and visible regions.
529