相关实验视频
Updated: May 29, 2025

07:28
Evolution of Staircase Structures in Diffusive Convection
Published on: September 5, 2018
6.4K
在火灾场景中对自动扶梯和楼梯的合疏散进行研究
Chunhua Zhang1,2, Xin Wu1,2, Hai Shen3
1College of Safety Science and Engineering, Liaoning Technical University, Fuxin, China.
PloS one
|February 4, 2025
概括
这项研究表明,结合自动扶梯和楼梯显著改善了火灾期间的商场疏散时间. 降低消防百叶窗进一步提高疏散效率,增加公共空间的安全性.
科学领域:
- 消防安全工程 消防安全工程
- 人群动力学模拟群众动力学模拟
- 建筑安全分析
背景情况:
- 商场疏散效率对于火灾紧急情况期间的公共安全至关重要.
- 传统的疏散模式往往忽视了自动扶梯和楼梯的联合使用.
- 了解火灾条件对疏散路线的影响至关重要.
研究的目的:
- 为了调查购物中心人员在火灾场景中使用自动扶梯和楼梯的联合疏散.
- 分析火源位置和消防快门部署对疏散时间的影响.
- 为了比较结合自动扶梯和楼梯疏散的效率与仅使用楼梯疏散的效率.
主要方法:
- 使用Pyrosim和Anylogic软件进行合疏散模拟.
- 在各种火灾条件下分析烟雾传输,温度,二氧化碳度和可见度.
- 开发了一个Anylogic疏散模型来比较不同的疏散策略和消防快门配置.
主要成果:
- 结合自动扶梯和楼梯疏散,与仅使用楼梯相比,最大疏散时间减少了23.37%.
- 消防百叶窗下降到1.8米提高了6.41%的疏散效率.
- 在模拟过程中,顶层的火源位置没有显著影响下层的疏散.
结论:
- 连接自动扶梯-楼梯疏散是购物中心消防安全的更有效的策略.
- 消防快门部署是一种可行的方法,可以提高疏散效率.
- 调查结果为改善大型公共空间的应急管理提供了实际见解.
相关概念视频
Design Example: Flow Through a Fire Extinguisher
113
A fire extinguisher that uses pressurized water relies on fluid dynamics principles to generate a high-velocity stream capable of suppressing flames. The water is stored at a much higher pressure inside the extinguisher than the surrounding atmosphere. This pressure difference forces the water to flow rapidly when the extinguisher is activated, and the behavior of the water as it exits the nozzle can be understood using fundamental equations of fluid dynamics.
The key to understanding how the...
The key to understanding how the...
113
Types of Building Separation Joints
188
Building separation joints divide large or complex building structures into smaller, discrete units that can move independently. These joints are categorized into three types: volume-change joints, settlement joints, and seismic separation joints.
Volume-change joints address the effects of expansion and contraction due to temperature and moisture variations. They are strategically placed at discontinuities in a building's mass where cracking is most likely and are spaced about 150 to 200...
Volume-change joints address the effects of expansion and contraction due to temperature and moisture variations. They are strategically placed at discontinuities in a building's mass where cracking is most likely and are spaced about 150 to 200...
188
Three-Phase Short Circuit—Unloaded Synchronous Machine
111
Conducting a three-phase short circuit test on an unloaded synchronous machine helps understand its impact on the system. The AC fault current's oscillogram, with the DC offset removed, reveals that the waveform amplitude decreases from an initially high value to a steady-state level for one phase of the machine.
This behavior occurs due to the magnetic flux produced by the short-circuit armature currents. Initially, these currents follow high-reluctance paths but eventually shift to...
This behavior occurs due to the magnetic flux produced by the short-circuit armature currents. Initially, these currents follow high-reluctance paths but eventually shift to...
111
Design Example: Designing Water Slide
98
When designing a water slide, controlling the speed of water flow is crucial for rider safety while maintaining an exciting experience. As water flows down the slide, gravity causes it to accelerate, with its speed at the bottom depending on the height from which it starts. The higher the slide, the more potential energy the water has at the top, which is converted into kinetic energy as it descends, increasing its speed.
Bernoulli's principle determines the water's velocity along the...
Bernoulli's principle determines the water's velocity along the...
98
Endotracheal Tube Extubation
349
Endotracheal tube extubation is a critical procedure in weaning patients from mechanical ventilation. It involves physically removing the oral or nasal endotracheal (ET) tube, marking the final step in liberating a patient from ventilatory support.
Procedure
Extubation removes the endotracheal tube (ETT) from the patient on mechanical ventilation. It requires a well-coordinated, multidisciplinary approach involving physicians, nurses, respiratory therapists, and other healthcare professionals....
Procedure
Extubation removes the endotracheal tube (ETT) from the patient on mechanical ventilation. It requires a well-coordinated, multidisciplinary approach involving physicians, nurses, respiratory therapists, and other healthcare professionals....
349
Transmission-based Precautions II: Airborne and Protective Environment
1.2K
Transmission-based precautions are for patients infected or suspected to be infected (or colonized) with organisms posing a significant risk to others. The transmission precautions include airborne and protective environment precautions.
Airborne precautions:
Use airborne precautions when treating patients known or suspected to have diseases that spread through the air—for example, tuberculosis or measles. These organisms are present in smaller droplets expelled by an infected person and...
Airborne precautions:
Use airborne precautions when treating patients known or suspected to have diseases that spread through the air—for example, tuberculosis or measles. These organisms are present in smaller droplets expelled by an infected person and...
1.2K