碳离子与质子的比较,用于集成模式离子成像
Mikaël Simard1, Ryan Fullarton1, Lennart Volz2
1Department of Medical Physics and Biomedical Engineering, University College London, London, UK.
Medical physics
|February 4, 2025
概括
与质子放射学 (pRads) 相比,碳离子放射学 (cRads) 为离子束治疗中的图像指导提供了更好的空间分辨率和低对比度检测. 这两种方法都保持了类似的水相当厚度准确度,但cRads显示了增强的骨结构可视化.
科学领域:
- 医学物理 医学物理
- 放射疗法成像技术 放射疗法成像技术
- 离子束治疗疗法 离子束治疗
背景情况:
- 图像引导对于离子束疗法至关重要,以尽量减少范围的不确定性.
- 传输离子放射学 (iRad) 显示出对图像引导的前景.
- 集成模式成像为iRads提供了一个与单个事件成像相容的临床替代方案.
研究的目的:
- 评估集成模式碳离子放射学 (cRads) 的图像质量指标.
- 为了将cRads的图像质量与质子放射图 (pRads) 进行比较.
主要方法:
- 使用塑料体积闪光灯和CCD摄像头获得iRads.
- 幻影被扫描以评估水相当厚度 (WET) 的准确性,空间分辨率和低对比度检测能力.
- 对各种光束间距的图像质量进行了评估,并比较了碳和质子离子.
主要成果:
- 与pRads (1.7 lp/cm) 相比,cRads显示出更高的空间分辨率 (3.7 lp/cm) 和较低的对比检测能力.
- 对于两种离子类型 (RMSE~1毫米) 的WET精度相似,并且在光束间距上稳定.
- cRads在人类形象头部幻影中改善了骨结构的对比度.
结论:
- 这项研究提供了第一个综合模式cRad和pRad图像质量指标的全面比较.
- cRads提供了更好的图像质量,特别是在空间分辨率和对比度检测方面.
- 对于离子束治疗应用,pRads保持可接受的图像质量和高WET精度.
相关概念视频
Chemical Ionization (CI) Mass Spectrometry
678
The molecular ion peak of a molecule in the mass spectrum provides vital information for molecular identification. However, conventional electron impact ionization can lead to the rapid dissociation of some molecular ions before they reach the detector. A milder ionization method is required to increase the lifetime of such ionized analyte molecules. Chemical ionization (CI) is a gas-phase protonation reaction useful for mass-analyzing analyte molecules that are easily protonated to yield the...
678
Inductively Coupled Plasma–Mass Spectrometry (ICP–MS): Overview
612
In inductively coupled plasma–mass spectrometry (ICP–MS), an inductively coupled plasma (ICP) torch is used as an atomizer and ionizer. Solid samples are dissolved and volatilized before being introduced into the high-temperature argon plasma, while solution samples are nebulized and passed through the high-temperature argon plasma. Plasma dissociates the analytes and ionizes their component atoms to form a mixture of positive ions and molecular species. The positive ions are then...
612
High-Resolution Mass Spectrometry (HRMS)
1.2K
The resolution of a mass spectrometer depends on the efficiency of separating ions with different ion masses. The mass of an atom is approximated to the sum of the masses of protons and neutrons inside, considering the masses of protons and neutrons as equal. However, the masses of the proton (1.6726 × 10−24 g) and neutron (1.6749 × 10−24 g) are not truly equal. There is a minor error in the expression of atomic masses relative to the simplest atom of hydrogen. For...
1.2K
¹³C NMR: ¹H–¹³C Decoupling
998
The probability of having two carbon-13 atoms next to each other is negligible because of the low natural abundance of carbon-13. Consequently, peak splitting due to carbon-carbon spin-spin coupling is not observed in spectra. However, protons up to three sigma bonds away split the carbon signal according to the n+1 rule, resulting in complicated spectra.
A broadband decoupling technique is used to simplify these complex, sometimes overlapping, signals. Broadband decoupling relies on a...
A broadband decoupling technique is used to simplify these complex, sometimes overlapping, signals. Broadband decoupling relies on a...
998
Mass Analyzers: Common Types
550
The quadrupole mass analyzer consists of four cylindrical metal rods arranged in a diamond carrying a DC voltage and a radio-frequency AC voltage. The motion of ions through the quadrupole depends on the field strength, causing only ions of a certain m/z to resonate successfully and strike the detector at a given field strength. Though the transmission rate for these analyzers is high, the exact elemental composition of the sample is not determined because of low resolution; however, they are...
550
Mass Analyzers: Overview
569
The mass analyzer is a crucial component of the mass spectrometer. In the ionization chamber, the vaporized sample is bombarded with a high-energy electron beam to generate a radical cation and further fragment into neutral molecules, radicals, and cations. A series of negatively charged accelerator plates accelerate the cations into the mass analyzer. The mass analyzer separates ions according to their mass-to-charge (m/z) ratios and then directs them to the detector. The common types of mass...
569