使用净计数方法对127个Xe追踪器测量的分析
M A Goodwin1, D L Chester1, G Galvin1
1AWE Aldermaston, Reading, RG7 4PR, UK.
Journal of environmental radioactivity
|February 5, 2025
概括
在内华达国家安全站点 (NNSS) 的地下化学爆炸后,Radon-227 (Xe) 被检测到3.5公里外. 这项研究分析了SAUNA QB系统的β-玛巧合数据,以测量其度.
科学领域:
- 核化学 核化学 核化学
- 地质物理学 地质物理学
- 环境监测 环境监测
背景情况:
- 物理实验1涉及内华达国家安全站点 (NNSS) 的放射性核化物追踪器的地下化学爆炸.
- 127Xe,一个放射性核酸标记物,被释放并被SAUNA QB采样器在3.5公里外检测到.
研究的目的:
- 分析和解释来自SAUNA Q系统的数据.
- 计算127Xe的测量活动度.
主要方法:
- 为地下化学爆炸部署测量系统.
- 使用β-玛巧合探测器系统进行放射性同位素测量.
- 来自SAUNA QB系统的巧合测量数据的分析.
主要成果:
- 在距离爆炸现场3.5公里处检测到127Xe.
- 使用SAUNA Q B系统成功测量了127Xe活动度.
结论:
- SAUNA QB系统有效地检测和测量了地下爆炸释放的127个Xe.
- 巧合测量数据为核爆炸监测提供了宝贵的见解.
更多相关视频
14:53In Situ Detection and Single Cell Quantification of Metal Oxide Nanoparticles Using Nuclear Microprobe Analysis
Published on: February 3, 2018
7.1K
08:22Measurement of Ultrafast Vibrational Coherences in Polyatomic Radical Cations with Strong-Field Adiabatic Ionization
Published on: August 6, 2018
6.8K
相关概念视频
Mass Analyzers: Overview
The mass analyzer is a crucial component of the mass spectrometer. In the ionization chamber, the vaporized sample is bombarded with a high-energy electron beam to generate a radical cation and further fragment into neutral molecules, radicals, and cations. A series of negatively charged accelerator plates accelerate the cations into the mass analyzer. The mass analyzer separates ions according to their mass-to-charge (m/z) ratios and then directs them to the detector. The common types of mass...
Mass Analyzers: Common Types
The quadrupole mass analyzer consists of four cylindrical metal rods arranged in a diamond carrying a DC voltage and a radio-frequency AC voltage. The motion of ions through the quadrupole depends on the field strength, causing only ions of a certain m/z to resonate successfully and strike the detector at a given field strength. Though the transmission rate for these analyzers is high, the exact elemental composition of the sample is not determined because of low resolution; however, they are...