[使用化学转移编码MRI与快速成像技术测量质子密度脂肪分量的精度]
Tomofumi Misaka1,2, Satoshi Takenaka1, Takayuki Ishida2
1Department of Radiology, Kindai University Nara Hospital.
Nihon Hoshasen Gijutsu Gakkai zasshi
|February 5, 2025
概括
快速成像技术使用化学转移编码MRI (CSE-MRI) 保持精确的质子密度脂肪分数 (PDFF) 测量. 使用SENSE (CS-SENSE) 的压缩传感为PDFF量化提供了在较高的降解因子时的最佳精度.
科学领域:
- 磁共振成像 (MRI) 是一种磁共振成像技术.
- 定量成像技术 定量成像技术
- 生物医学工程 生物医学工程
相关概念视频
Proton (¹H) NMR: Chemical Shift
1.5K
Organic molecules primarily contain carbon and hydrogen atoms. While all the hydrogen isotopes are NMR-active, protium or hydrogen-1 is the most abundant. It has a significant energy separation between its nuclear spin states due to its large gyromagnetic ratio. As per Boltzmann's distribution, an increase in the energy separation implies a greater excess population of nuclei available for excitation, resulting in a strong NMR absorption signal.
Absorption signals of all the protium nuclei...
Absorption signals of all the protium nuclei...
1.5K
NMR Spectroscopy: Chemical Shift Overview
1.4K
The position of the absorption signal of a sample is reported relative to the position of the signal of tetramethylsilane (TMS), which is added as an internal reference while recording spectra. The difference between the absorption frequencies of the sample and TMS (in Hz) is divided by the spectrometer operating frequency (in MHz) to obtain a dimensionless quantity called the chemical shift. It is reported on the δ (delta) scale and expressed in parts per million.
For instance, the proton...
For instance, the proton...
1.4K
¹³C NMR: Distortionless Enhancement by Polarization Transfer (DEPT)
1.0K
When proton-coupled carbon-13 spectra are simplified by a broadband proton decoupling technique, structural information about the coupled protons is lost. Distortionless enhancement by polarization transfer (DEPT) is a technique that provides information on the number of hydrogens attached to each carbon in a molecule. While the DEPT experiment utilizes complex pulse sequences, the pulse delay and flip angle are specifically manipulated. The resulting signals have different phases depending on...
1.0K
Chemical Shift: Internal References and Solvent Effects
591
In an NMR sample, precise measurement of the absolute absorption frequencies of nuclei is difficult. A standard internal reference compound is added, and the frequency difference between the reference signal and sample signals is measured.
The internal reference compound generally used in NMR spectroscopy is tetramethylsilane (TMS). TMS is preferred because it is chemically inert, soluble in NMR solvents, and easily removable. Also, the highly shielded methyl protons in TMS yield an intense...
The internal reference compound generally used in NMR spectroscopy is tetramethylsilane (TMS). TMS is preferred because it is chemically inert, soluble in NMR solvents, and easily removable. Also, the highly shielded methyl protons in TMS yield an intense...
591
Insensitive Nuclei Enhanced by Polarization Transfer (INEPT)
222
Insensitive Nuclei Enhanced by Polarization Transfer (INEPT) is an advanced Nuclear Magnetic Resonance (NMR) technique specifically designed to detect and enhance the signals of low-abundance nuclei, such as carbon-13 and nitrogen-15, in small molecules. The fundamental principle behind INEPT is the transfer of polarization from a more abundant and highly polarizable nucleus, typically hydrogen-1, to the low-abundance nucleus of interest. This process effectively boosts the NMR signal of the...
222
Magnetic Resonance Imaging
4.9K
Magnetic resonance imaging (MRI) is a noninvasive medical imaging technique based on a phenomenon of nuclear physics discovered in the 1930s, in which matter exposed to magnetic fields and radio waves was found to emit radio signals. In 1970, a physician and researcher named Raymond Damadian noticed that malignant (cancerous) tissue gave off different signals than normal body tissue. He applied for a patent for the first MRI scanning device in clinical use by the early 1980s. The early MRI...
4.9K


