维度精度在四种类型的第四类型的石头死在延迟倒后:一个比较研究
Sriharsha Pudi1, Arun Rosan David Raj2, Hemamalini Balaji2
1Department of Prosthodontics and Crown and Bridges, MNR Dental College and Hospital, Sangareddy, Telangana, India.
Journal of pharmacy & bioallied sciences
|February 10, 2025
概括
第四类牙科压石的尺寸精度因品牌和倒时间而异. ZODENTA在1小时的时间表中显示出最佳准确性,而FUJI在24小时的倒水间隔中表现出色.
科学领域:
- 牙科材料科学 牙科材料科学
- 生物材料工程 生物材料工程
背景情况:
- 精确的牙造型对于假牙和修复性牙科至关重要.
- 第四类石膏 (石) 由于其高强度和低膨胀性,广泛用于牙科模型.
- 延迟注入牙印记可能会损害石膏件的尺寸精度.
研究的目的:
- 为了评估和比较四种不同类型IV模块的尺寸精度.
- 评估延迟倒间隔 (1小时与24小时) 对这些材料尺寸稳定的影响.
主要方法:
- 准备了80个标准化的牙印记样本.
- 四个品牌的IV型模块石被倒在两个不同的时间间隔:打印后1小时和24小时.
- 测量尺寸准确度是使用配置投影仪进行测量.
主要成果:
- 当ZODENTA在1小时后倒入时,其尺寸变化最小.
- 在24小时后倒时,FUJI表现出最小的尺寸变化.
- 总的来说,在所有测试品牌中,在1小时和24小时倒水间隔之间的尺寸精度差异被发现是最小的.
结论:
- 第四类压石的选择可以根据倒间隔影响尺寸准确性.
- 建议ZODENTA用于立即倒水,而FUJI可能更适合延迟倒水的场景.
- 需要进一步的研究,以充分了解延迟倒对牙修复准确性的长期影响.
相关概念视频
Design Example: Dimensioning of Concrete Masonry Construction
84
For the construction of a storeroom using concrete masonry units, it's essential to align the dimensions of the structure with the actual sizes of the blocks and the intended mortar joints. On the site in question, there's a stockpile of concrete masonry blocks with a nominal size of eight by eight by sixteen inches, which are to be used in the construction of the storeroom.
The site engineer has laid out a plan for the storeroom with external dimensions of twelve feet in length and...
The site engineer has laid out a plan for the storeroom with external dimensions of twelve feet in length and...
84
Testing Water Quality
103
When the quality of water for concrete preparation is uncertain, its impact on the setting time of cement and compressive strength of mortar is assessed by comparison with de-ionized or distilled water benchmarks. American Society for Testing and Materials (ASTM) C1602 requires the setting times to be within 90 minutes of the control, British Standard (BS) 3146:1980 allows a 30-minute variance in the initial setting, while British Standards European Norm (BS EN) 1008 specifies initial setting...
103
Types of Cement I
95
Portland cement comes in several types, each with distinct properties and applications based on their chemical composition and hydration characteristics:
Type I (Ordinary Portland Cement) is widely used for general construction where special properties are not required. It has moderate sulfate resistance and heat of hydration.
Type II (Modified Cement) offers moderate resistance to sulfate attack and a lower rate of heat development compared to Type I. It is suitable for structures in...
Type I (Ordinary Portland Cement) is widely used for general construction where special properties are not required. It has moderate sulfate resistance and heat of hydration.
Type II (Modified Cement) offers moderate resistance to sulfate attack and a lower rate of heat development compared to Type I. It is suitable for structures in...
95
Slump Test
128
The slump test is a widely used method to measure the workability of concrete. It employs a 12-inch high truncated cone mold that tapers from eight inches at the base to four inches at the top. Before testing, the mold is securely attached to a flat base and dampened.
Concrete is poured into the mold in three layers to conduct the test. Each layer is compacted 25 times with a steel tamping rod, which has a five-eighths-inch diameter and a rounded end, to ensure even distribution and eliminate...
Concrete is poured into the mold in three layers to conduct the test. Each layer is compacted 25 times with a steel tamping rod, which has a five-eighths-inch diameter and a rounded end, to ensure even distribution and eliminate...
128
Pore Size Distribution
82
In concrete, the pore size distribution significantly influences the material's properties. Capillary pores, markedly larger than gel pores, form a vast network within partially hydrated cement paste, reducing the concrete's strength and increasing its permeability. This heightened permeability leads to a greater risk of damage from environmental factors like freeze-thaw cycles and chemical attacks, with the extent of vulnerability also being tied to the water-to-cement ratio.
Adequate...
Adequate...
82


