共振声学类风湿测量用于评估出血患者的血凝固
Weiping Li1, Connor M Bunch2,3, Sufyan Zackariya2
1Department of Biomedical Engineering, University of Michigan, Ann Arbor, MI, USA.
Scientific reports
|February 11, 2025
概括
共振声学类风湿测量 (RAR) 显示出有前途的方法,用于评估出血患者的血凝固. 这种技术可能有助于指导输血血液产品,以改善出血管理.
科学领域:
- 生物医学工程 生物医学工程
- 血液学 血液学 血液学
- 类风病学 类风病学 类风病学
背景情况:
- 危及生命的出血需要快速的静血表型.
- 目前的方法可能缺乏及时临床决策所需的敏感性.
- 血液出血患者的有效管理需要精确评估凝血.
研究的目的:
- 评估共振声学类风湿测量 (RAR) 作为评估血凝固的新方法.
- 为了确定RAR参数是否可以预测出血患者需要输血的血液产品.
- 探索利用RAR数据用于临床决策支持的机器学习模型的潜力.
主要方法:
- 在38名出血患者中,共振声学类风湿测量 (RAR) 用于测量血粘弹性特性.
- 在不同的激活剂和试剂条件下评估了凝血动态.
- 在RAR参数上训练了一个二次分类器,以预测输血需求.
- 罕见的ARAR结果与传统的血小板结晶学 (TEG) 参数相关.
主要成果:
- RAR成功捕获了动态血凝固特征.
- RAR参数与TEG反应时间和功能性纤维素原相关,特别是在考虑并发症时.
- 使用RAR数据的机器学习模型在预测新鲜冷血和冷流体输血方面取得了适度至高的准确性.
- 该研究证明了RAR用于凝血评估的可行性.
结论:
- 共振声学类风湿测量是一种可行的技术,用于评估出血患者的血凝固.
- 与机器学习相结合,RAR显示出在重症监护机构指导输血决策的潜力.
- 需要对更大的患者队伍进行进一步验证,以确定RAR作为可靠,具有成本效益的血液静止试验.
相关概念视频
Equipments Used To Measure Blood Pressure
Direct Method
This invasive approach involves cannulating a peripheral artery. During each cardiac contraction, pressure generates mechanical motion within the catheter, transmitted through rigid, fluid-filled tubing to a transducer. This transducer converts mechanical motion into electrical signals displayed as waveforms on a monitor. An automatic flushing system prevents blood backflow. Due to the potential risk of unexpected arterial blood loss, this method is primarily used in intensive...
This invasive approach involves cannulating a peripheral artery. During each cardiac contraction, pressure generates mechanical motion within the catheter, transmitted through rigid, fluid-filled tubing to a transducer. This transducer converts mechanical motion into electrical signals displayed as waveforms on a monitor. An automatic flushing system prevents blood backflow. Due to the potential risk of unexpected arterial blood loss, this method is primarily used in intensive...
Assessment of blood pressure in brachial artery(two-step method)
Measuring blood pressure is a fundamental skill in healthcare that aids in diagnosing and monitoring hypertension and other cardiovascular conditions. An aneroid sphygmomanometer, commonly used in clinical settings, offers a manual and precise method for blood pressure measurement. The technique for using this instrument involves specific steps that must be carefully executed to ensure accuracy. The following detailed description outlines a two-step technique for assessing blood pressure using...
Assessing Blood pressure using a doppler ultrasound
To obtain accurate blood pressure measurements in clinical settings, especially when traditional methods are insufficient, healthcare professionals utilize the Doppler ultrasound technique. This method uses high-frequency sound waves to detect blood flow within the arteries, which is crucial for patients with conditions that complicate circulatory system assessment.
Pre-Procedural Guidelines for Doppler Ultrasound Blood Pressure Assessment:
Preparation of Equipment:
Pre-Procedural Guidelines for Doppler Ultrasound Blood Pressure Assessment:
Preparation of Equipment:
Measurement of Blood Pressure
Assessing blood pressure is a standard procedure executed in virtually all medical environments. The method utilized today was established over a hundred years ago by an innovative Russian doctor, Dr. Nikolai Korotkoff. The soft ticking noise, known as Korotkoff sounds, heard while taking blood pressure readings results from turbulent blood flow within the vessels. The apparatus required for this procedure includes a sphygmomanometer, a blood pressure cuff attached to a gauge, and a stethoscope.
Measurement of Air Content in Concrete
Air content measurement in concrete is critical for ensuring structural integrity and durability of concrete structures, especially in environments prone to severe weather conditions. Accurate air content analysis optimizes concrete's resistance to freeze-thaw cycles and enhances its workability and strength. Several methods are standardized under ASTM guidelines to measure the air content in fresh concrete, each suitable for different concrete types and conditions.
The pressure method,...
The pressure method,...
Blood Studies for Cardiovascular System I: Cardiac Biomarkers
Cardiac biomarkers are enzymes, proteins, and hormones released into the blood when cardiac cells are injured. They are powerful tools for triaging.
The essential diagnostic tools for detecting myocardial necrosis and monitoring individuals suspected of having acute coronary syndrome (ACS) include:
Troponins
Troponins, particularly cardiac troponins I and T, are the most precise and sensitive markers of myocardial injury. They are detectable within 4-6 hours of myocardial injury and remain...
The essential diagnostic tools for detecting myocardial necrosis and monitoring individuals suspected of having acute coronary syndrome (ACS) include:
Troponins
Troponins, particularly cardiac troponins I and T, are the most precise and sensitive markers of myocardial injury. They are detectable within 4-6 hours of myocardial injury and remain...