无袖式血压监测器用于家庭和医院使用
Toshiyo Tamura1, Ming Huang2,3
1Healthcare Robotics Institute, Future Robotics Organization, Waseda University, Tokyo 169-8050, Japan.
Sensors (Basel, Switzerland)
|February 13, 2025
概括
无袖式血压计为高血压管理的传统设备提供了一个有希望的替代方案. 本综述探讨了它们的原理,发展和临床准确性的验证.
科学领域:
- 生物医学工程 生物医学工程
- 心血管研究的心血管研究.
- 医疗器械技术 医疗器械技术
背景情况:
- 高血压是一种全球性健康威胁,由于传统袖口式监测器的局限性,往往无法检测到.
- 无袖式血压监测器为连续和方便的高血压检测提供了一个新的解决方案.
- 目前面临的挑战包括满足临床性能标准以实现广泛采用.
研究的目的:
- 审查无袖血压监测技术的原则和现状.
- 讨论已批准的医疗器械和家庭和临床环境的性能要求.
- 提供关于在不同环境中验证这些设备的准确性的见解.
主要方法:
- 科学出版物和监管批准的文献审查.
- 分析无袖血压测量背后的技术原理.
- 对性能标准和验证方法的检查.
主要成果:
- 综述各种无袖监控原则 (例如脉冲传输时间,脉冲波分析).
- 识别目前批准的医疗器械及其技术基础.
- 讨论策略,以满足严格的准确性和可靠性要求.
结论:
- 无袖式血压计具有改善高血压管理的巨大潜力.
- 标准化验证协议对于确保设备的准确性和临床实用性至关重要.
- 需要进一步的研究和开发来优化性能,并促进更广泛的临床整合.
相关概念视频
Equipments Used To Measure Blood Pressure
789
Direct Method
This invasive approach involves cannulating a peripheral artery. During each cardiac contraction, pressure generates mechanical motion within the catheter, transmitted through rigid, fluid-filled tubing to a transducer. This transducer converts mechanical motion into electrical signals displayed as waveforms on a monitor. An automatic flushing system prevents blood backflow. Due to the potential risk of unexpected arterial blood loss, this method is primarily used in intensive...
This invasive approach involves cannulating a peripheral artery. During each cardiac contraction, pressure generates mechanical motion within the catheter, transmitted through rigid, fluid-filled tubing to a transducer. This transducer converts mechanical motion into electrical signals displayed as waveforms on a monitor. An automatic flushing system prevents blood backflow. Due to the potential risk of unexpected arterial blood loss, this method is primarily used in intensive...
789
Special considerations while measuring blood pressure
701
When assessing blood pressure (BP), healthcare professionals must consider various factors and potential unexpected outcomes to ensure accurate readings and provide proper patient care. Adhering to these guidelines is essential to achieving the most reliable results.
Monitoring Both Arms:
Monitoring BP in both arms during the initial assessment is advisable, as the systolic value may differ by five to ten mm Hg between arms. For subsequent BP assessments, use the arm with the higher reading.
Monitoring Both Arms:
Monitoring BP in both arms during the initial assessment is advisable, as the systolic value may differ by five to ten mm Hg between arms. For subsequent BP assessments, use the arm with the higher reading.
701
Measurement of Blood Pressure
822
Assessing blood pressure is a standard procedure executed in virtually all medical environments. The method utilized today was established over a hundred years ago by an innovative Russian doctor, Dr. Nikolai Korotkoff. The soft ticking noise, known as Korotkoff sounds, heard while taking blood pressure readings results from turbulent blood flow within the vessels. The apparatus required for this procedure includes a sphygmomanometer, a blood pressure cuff attached to a gauge, and a...
822
Pre-Procedural Guidelines for Assessing Blood Pressure
519
Accurate blood pressure assessment is crucial for diagnosing and managing various health conditions. To ensure the reliability of these measurements, healthcare professionals must adhere to standardized pre-procedural guidelines. These guidelines enhance patient safety and improve the overall quality of healthcare. The following steps are essential for obtaining accurate and consistent blood pressure readings, from using the appropriate tools to ensuring effective communication with the...
519
Sites for measruring blood pressure
1.4K
Blood pressure measurement is a fundamental clinical procedure, providing crucial data for assessing cardiovascular health. Among the various sites for this measurement, the brachial and popliteal arteries are predominantly utilized due to their accessibility and the reliability of their readings. This lesson delves into the anatomical significance, methodology, and considerations of measuring blood pressure at these locations.
The Brachial Artery: Primary Site for Blood Pressure Measurement
The Brachial Artery: Primary Site for Blood Pressure Measurement
1.4K
Assessment of blood pressure in brachial artery(one-step method)
554
This procedural guide systematically measures blood pressure using an oscillometric digital sphygmomanometer, emphasizing accuracy, patient safety, and comfort.
Prepare for the Procedure:
Prepare for the Procedure:
554