改进了灵活直流电网的活性电流限制控制,以考虑选择性和更高的故障电阻的影响
Xiaohua Qin1, Junjie Hou2, Yanfang Fan3
1School of Electrical Engineering, Xinjiang University, Urumqi, China.
Scientific reports
|February 13, 2025
概括
本研究介绍了灵活直流电网的主动电流限制控制 (ACLC) 策略. 新方法改善了故障识别和电流限制,提高了电网保护的选择性和适应性.
科学领域:
- 电气工程 电气工程
- 电力系统 电力系统
- 控制系统 控制系统
背景情况:
- 目前用于直流电网的模块化多层转换器的限制策略面临选择性和故障影响的挑战.
- 现有的方法可以在非故障位置中断电力传输,并且可能无法有效处理不同的故障严重程度.
研究的目的:
- 提出一个主动电流限制控制 (ACLC) 战略,增强故障识别能力.
- 提高灵活直流电网中电流限制控制的选择性和适应性.
主要方法:
- 使用逆行波 (TW) 的斜率来识别断层区域.
- 构建基于TW斜率的电流限制系数,用于故障电流控制.
- 实现振幅控制,以提高适应故障阻力的能力.
主要成果:
- 拟议的ACLC战略表明,故障处理的选择性得到了改善.
- 该策略有效地减少了对直流断路器 (DCCB) 的技术要求.
- 观察到ACLC对不同故障阻力水平的增强适应性.
结论:
- 该ACLC战略为DC电网的故障管理提供了选择性和适应性的解决方案.
- 这种方法提高了整体电网保护性能和可靠性.
更多相关视频
06:45Design and Application of a Fault Detection Method Based on Adaptive Filters and Rotational Speed Estimation for an Electro-Hydrostatic Actuator
Published on: October 28, 2022
1.6K
11:44Real-Time DC-dynamic Biasing Method for Switching Time Improvement in Severely Underdamped Fringing-field Electrostatic MEMS Actuators
Published on: August 15, 2014
10.3K
相关概念视频
Line Protection with Impedance Relays
64
Coordinating time-delay overcurrent relays in complex radial systems and directional overcurrent relays in multi-source transmission loops can be challenging. Impedance relays address these issues by responding to the voltage-to-current ratio, specifically measuring the apparent impedance of a line. These relays become more sensitive during faults as current increases and voltage decreases, thereby reducing the apparent impedance.
Under normal conditions, low load currents keep the measured...
Under normal conditions, low load currents keep the measured...
64
Reclosers and Fuses
79
Automatic circuit reclosers enhance the protection of distribution circuits by interrupting and auto-reclosing an AC circuit according to a preset sequence. They effectively manage temporary faults on overhead distribution lines, often caused by tree limbs or wildlife, by briefly disrupting service to improve overall reliability. However, contact with reclosers or energized broken conductors on the ground can pose serious hazards.
A comprehensive protection scheme for radial distribution...
A comprehensive protection scheme for radial distribution...
79
Directional Relays
87
Directional relays, essential for managing unidirectional fault currents, enhance the safety and efficiency of power systems. On power lines equipped with directional relays, faults downstream (to the right) of the current transformer typically cause the fault current to lag the bus voltage by approximately 90 degrees, known as the forward direction. In contrast, upstream (left-side) faults may result in the fault current leading the bus voltage by nearly 90 degrees, termed the reverse...
87
Power System Three-Phase Short Circuits
72
Determining the subtransient fault current in a power system involves representing transformers by their leakage reactances, transmission lines by their equivalent series reactances, and synchronous machines as constant voltage sources behind their subtransient reactances. In this analysis, certain elements are excluded, such as winding resistances, series resistances, shunt admittances, delta-Y phase shifts, armature resistance, saturation, saliency, non-rotating impedance loads, and small...
72
Series R—L Circuit Transients
82
In a series resistor-inductor (R-L) circuit, closing the switch at the start of the time period simulates a three-phase short circuit, a fault condition where all three phases of an unloaded synchronous machine are short-circuited. When there is no fault impedance and no initial current, the initial voltage is determined by the phase angle of the source voltage.
Using Kirchhoff's Voltage Law (KVL) to analyze this circuit helps determine the total asymmetrical fault current, which consists...
Using Kirchhoff's Voltage Law (KVL) to analyze this circuit helps determine the total asymmetrical fault current, which consists...
82
Differential Relays
100
Differential relays are used to protect generators, buses, and transformers by comparing electrical quantities at different points. When a fault occurs, the difference in current between the two points triggers the relay to operate, opening the circuit breaker. Under normal conditions, the current entering (i1) and leaving (i2) a generator are equal. When a fault occurs, however, these currents become unequal, and the difference current flows in the relay operating coil, causing the relay to...
100