脱碳非碳:逐步淘汰互联电网中最强大的温室气体的效益成本分析
Song Xiao1, Yuting Yang2, Yubei Li3,4
1School of Electrical Engineering and Automation, Wuhan University, Wuhan, Hubei 430072, China.
Environmental science & technology
|February 14, 2025
概括
在高压气体绝缘开关装置中消除硫六化物 (SF) 通常是有益的,提供具有成本效益的温室气体减排. 当地因素和碳成本显著影响SF6替代策略的社会经济可行性.
科学领域:
- 环境科学 环境科学
- 能源政策 能源政策
- 经济学 经济学 经济学
背景情况:
- 六化硫 (SF) 是最强大的温室气体,广泛用于电力行业的高压气体绝缘开关设备 (GIS).
- 预计不断增加的电气化和可再生能源的整合将导致GIS装置的升级以及随后的SF排放.
研究的目的:
- 对消除高压GIS设备中的SF6的社会经济可行性进行首次全面分析.
- 为评估SF6替代策略开发一个灵活和可扩展的效益成本分析框架.
主要方法:
- 开发一个效益成本分析框架.
- 利用中国电力行业的数据来评估SF6消除策略.
- 分析关键因素,包括碳的社会成本和监管合规性.
主要成果:
- 在GIS中消除SF6的高级别政策通常是有益的.
- 根据当地实施环境,SF6替代的净收益有很大差异.
- 碳的社会成本和坚定遵守SF标准被确定为关键决定因素.
结论:
- 投资SF替代品是减少温室气体排放的高成本有效方法.
- 与风能和太阳能发电技术相比,SF6替代品在减排方面表现出更高的成本效益.
相关概念视频
Series Impedances: Three-Phase Line
90
Calculating series impedances for a three-phase overhead line involves evaluating resistances and inductive reactances in a network with three-phase and multiple neutral conductors grounded at regular intervals.
Using Kirchhoff's laws, an integro-differential equation for the network is derived. This equation accounts for unbalanced phase currents, which may induce return currents through neutral wires and the earth, seeking the least impedance path. Earth return conductors can replace the...
Using Kirchhoff's laws, an integro-differential equation for the network is derived. This equation accounts for unbalanced phase currents, which may induce return currents through neutral wires and the earth, seeking the least impedance path. Earth return conductors can replace the...
90
Fast Decoupled and DC Powerflow
154
The fast decoupled power flow method addresses contingencies in power system operations, such as generator outages or transmission line failures. This method provides quick power flow solutions, essential for real-time system adjustments. Fast decoupled power flow algorithms simplify the Jacobian matrix by neglecting certain elements, leading to two sets of decoupled equations:
154
Power in a Three-Phase Circuit
286
Three-phase systems have two configurations: the wye and delta. A star configuration can be three or four wires; in a delta configuration, the components are connected in a closed loop. Instantaneous power refers to the power value at a precise moment, and in a balanced three-phase system, it is constant. This is because the sum of the instantaneous powers in the three phases remains steady over time, despite individual fluctuations, due to the symmetry and phase relationship. The total...
286
The Power Flow Problem and Solution
157
Power flow problem analysis is fundamental for determining real and reactive power flows in network components, such as transmission lines, transformers, and loads. The power system's single-line diagram provides data on the bus, transmission line, and transformer. Each bus k in the system is characterized by four key variables: voltage magnitude Vk, phase angle δk, real power Pk, and reactive power Qk. Two of these four variables are inputs, while the...
157
Three-Phase Circuits
383
AC power distribution systems have three categories: single-phase, two-phase, and three-phase systems. The single-phase circuit, common in residential settings, typically employs a two-wire system connecting a single AC source to various loads. These circuits support standard household appliances operating at 120 volts (V) and 240 V, such as lamps, televisions, and microwaves. The first generators, Niagara Falls hydro plant installed in 1895, were two-phase and designed by Nikola Tesla. The...
383
Kirchoff's Laws using Phasors
382
Analyzing AC circuits in electrical systems is a fundamental aspect of electrical engineering. In these circuits, AC power is supplied from a distribution panel and wired to various household appliances in parallel. To perform a comprehensive analysis, electrical engineers use Kirchhoff's voltage and current laws, which are equally applicable in AC circuits as in DC circuits.
Kirchhoff's voltage law (KVL) states that the sum of phasor voltages around a closed loop in an AC circuit...
Kirchhoff's voltage law (KVL) states that the sum of phasor voltages around a closed loop in an AC circuit...
382