用于测量断开开关旋转角度的光纤传感器
Zhang Jing1, Gu Qingchuan2, Wan Pu3
1School of Physics and Information Engineering, Zhaotong University, Zhaotong, 657000, Yunnan, China. 3052366988@qq.com.
Scientific reports
|February 14, 2025
概括
这项研究引入了一种用于测量高压隔离开关角度的新系统. 它通过使用双路径硬件和基于Sparrow搜索算法的软件方法来补偿激光光的波动来提高准确性.
科学领域:
- 电气工程 电气工程
- 测量科学 测量科学 测量科学
- 传感器技术 传感器技术
背景情况:
- 传统的电子角度传感器在高压隔离开关上面临安装挑战.
- 准确的角度测量对于高压设备的安全和高效运行至关重要.
研究的目的:
- 开发一种用于高压隔离开关角度测量的新系统.
- 解决传统传感器在高压环境中的局限性.
- 为了提高角度检测的准确性和可靠性.
主要方法:
- 一个系统将开关旋转角度转换为线性运动以进行测量.
- 使用光电转换技术进行角度计算.
- 实现基于硬件的双光路径,获得补偿.
- 使用基于Sparrow搜索算法的反向传播 (SSA-BP) 神经网络进行软件补偿.
主要成果:
- 成功地将旋转运动转换为线性运动,用于角度测量.
- 减少因光源波动引起的非线性输出误差.
- 通过双路径补偿实现了0.18的平均绝对误差.
- 通过SSA-BP补偿,实现了0.3的平均绝对误差.
结论:
- 拟议的系统有效地测量了高压隔离开关的角度.
- 硬件和软件补偿方法显著提高了检测准确度.
- 该系统为高压应用中的角度测量提供了可行的解决方案.
相关概念视频
Directional Relays
87
Directional relays, essential for managing unidirectional fault currents, enhance the safety and efficiency of power systems. On power lines equipped with directional relays, faults downstream (to the right) of the current transformer typically cause the fault current to lag the bus voltage by approximately 90 degrees, known as the forward direction. In contrast, upstream (left-side) faults may result in the fault current leading the bus voltage by nearly 90 degrees, termed the reverse...
87
Angle of Twist: Problem Solving
256
An electric motor applies a torque of 700 N·m to an aluminum shaft, triggering a stable rotation. Two pulleys, B and C, are subjected to torques of 300 N·m and 400 N·m, respectively. The modulus of rigidity is provided as 25 GPa. With the knowledge of the length and diameter of each segment, the twist angle between the two pulleys can be computed. First, a section cut is made between pulleys B and C, and the cut cross-section is analyzed using a free-body diagram. Given that the...
256
Differential Relays
100
Differential relays are used to protect generators, buses, and transformers by comparing electrical quantities at different points. When a fault occurs, the difference in current between the two points triggers the relay to operate, opening the circuit breaker. Under normal conditions, the current entering (i1) and leaving (i2) a generator are equal. When a fault occurs, however, these currents become unequal, and the difference current flows in the relay operating coil, causing the relay to...
100
Potentiometer
518
Voltage and current measurements using a standard voltmeter and ammeter alter the circuit being measured either by drawing or resisting the current flow, which introduces uncertainties in the measurements. Null measurements balance the voltages so that no current flows through the measuring device and, therefore, no alterations occur in the measured circuit.
Suppose the emf of a battery needs to be measured. If the battery is directly connected to a standard voltmeter, the measured quantity is...
Suppose the emf of a battery needs to be measured. If the battery is directly connected to a standard voltmeter, the measured quantity is...
518