相关实验视频
Updated: May 27, 2025

10:33
Research and Development of High-performance Explosives
Published on: February 20, 2016
17.5K
一种法医工程技术,用于分析爆炸事件
Ganchai Tanapornraweekit1, Thimira Abeysinghe2, Somnuk Tangtermsirikul3
1Construction and Maintenance Technology Research Center (CONTEC), School of Civil Engineering and Technology, Sirindhorn International Institute of Technology (SIIT), Thammasat University, Khlong Luang, Pathum Thani, Thailand.
Journal of forensic sciences
|February 17, 2025
概括
法医工程模拟估计,在Erawan神社爆炸事件中,TNT相当于3公斤. 该研究验证了爆炸压力和碎片撞击模型,预测了加强国土安全的致命区域.
科学领域:
- 法医工程法医学工程法医工程法医学
- 爆炸分析的分析.
- 计算机建模 计算建模
背景情况:
- 目前用于分析爆炸事件的法医实践需要验证.
- 准确确定爆炸物重量和致命区域对于事件重建和公共安全至关重要.
研究的目的:
- 验证分析爆炸事件的法医工程技术.
- 模拟爆炸碎片和压力,以确定爆炸重量和预测致命区域.
- 将这些方法应用于2015年曼谷的Erawan神爆炸事件.
主要方法:
- 有限元 (FE) 分析以模拟爆炸压力和碎片撞击.
- 将FE分析结果与Erawan神社爆炸现场的结构损伤进行比较.
- 应用波恩的致命性曲线用于爆炸压力和50%的致命性概率碎片撞击.
主要成果:
- 据估计,Erawan神社爆炸事件的裸弹重量相当于3公斤的TNT.
- 模拟的爆炸压力和碎片撞击的致命区域与观察到的人类伤害有很好的一致性.
- 综合模型成功预测了爆炸的后果.
结论:
- 提出的法医工程技术是分析爆炸事件的有效方法.
- 这种方法可以加强国土安全管理和政策.
- 该研究通过改进事件分析,有助于发展更安全的社区.
相关概念视频
Atomic Emission Spectroscopy: Lab
141
AES is a powerful analytical technique, especially effective when used with plasma sources, producing abundant spectra in characteristic emission lines. The Inductively Coupled Plasma (ICP), in particular, yields superior quantitative analytical data due to its high stability, low noise, low background, and minimal interferences under optimal experimental conditions. However, newer air-operated microwave sources are emerging as promising alternatives that could be more cost-effective than...
141
Flame Photometry: Lab
210
In a flame photometer, when a solution like potassium chloride is aspirated into the flame, the solvent evaporates, leaving behind dehydrated salt. This salt dissociates into free gaseous atoms in their ground state. Some of these atoms absorb energy from the flame, leading to their excitation. The excited atoms return to the ground state, emitting photons at characteristic wavelengths. Because only electronic transitions are involved, the resulting emission lines are very narrow. The intensity...
210
Flame Photometry: Overview
432
Flame photometry, also known as flame emission spectrometry, is a technique used for the qualitative and quantitative analysis of elements present in a sample using a flame as the source of excitation energy. The concept of flame photometry was realized in the early 1860s by Kirchhoff and Bunsen, who discovered that specific elements emit characteristic radiation when excited in flames. The first instrument developed for this purpose was used to measure sodium (Na) in plant ash using a Bunsen...
432
Constant Volume Calorimetry
26.8K
Calorimeters are useful to determine the heat released or absorbed by a chemical reaction. Coffee cup calorimeters are designed to operate at constant (atmospheric) pressure and are convenient to measure heat flow (or enthalpy change) accompanying processes that occur in solution at constant pressure. A different type of calorimeter that operates at constant volume, colloquially known as a bomb calorimeter, is used to measure the energy produced by reactions that yield large amounts of heat and...
26.8K
Atomic Emission Spectroscopy: Overview
1.4K
Atomic emission spectroscopy (AES) is an analytical technique used to determine the elemental composition of a sample by analyzing the light emitted from excited atoms. In AES, atoms in a sample are excited to higher energy levels by thermal energy from high-temperature sources, such as plasma, arcs, or sparks. When these excited atoms return to lower energy states, they emit light at specific wavelengths characteristic of each element. The resulting atomic emission spectrum, which consists of...
1.4K
Atomic Emission Spectroscopy: Interference
160
In atomic emission spectroscopy (AES), high-temperature atomizers excite a broad range of elements and molecules that generate complex emissions from sources such as oxides, hydroxides, and flame combustion products in the flame or plasma. Several strategies can be employed to minimize spectral interferences caused by overlapping emission lines or bands. These include increasing instrument resolution, choosing alternative emission lines, optimally placing the detector in low-background regions,...
160