如何避免和处理放置水泥增大窗口皮肤脚螺丝的问题?
Fernando Padilla-Lichtenberger1,2, Federico Landriel1, Alfredo Guiroy3
1Servicio de Neurocirugía, Sección Patología Raquimedular, Hospital Italiano de Buenos Aires, Buenos Aires, Argentina.
Neurosurgery practice
|February 17, 2025
概括
用水泥增强的窗户式脚螺丝可以改善骨质差的固定. 这项研究提供了10个关键的技巧,以提高技术性能,并最大限度地降低并发症,以成功的水泥增强窗户脚螺丝放置.
科学领域:
- 脊柱外科手术 脊柱外科手术
- 整形外科手术 整形外科手术
- 生物材料是一种生物材料.
背景情况:
- 带有中央头和窗户的脚螺丝使水泥增强成为可能.
- 这种技术可以减少螺丝松动和拔出风险,特别是在骨质不佳的患者中.
研究的目的:
- 为解决问题提供实际建议,并最大限度地减少与水泥增强窗口脚螺丝相关的并发症.
- 为成功实施这种外科手术技术提供指导.
主要方法:
- 这是一项多中心的回顾性研究,涉及137名患者的800多个水泥增强窗口脚螺丝 (CAFPS).
- 该技术使用了二维光学指导的技术.
- 对常见挑战和并发症的分析为编制10个基本提示提供了信息.
主要成果:
- 确定了成功安置CAFPS的十个关键提示.
- 关键建议包括适当的指示,在骨质疏松症的骨中使用K线,精确的螺丝测量,避免双皮裂,窗户清洁,保护螺丝延伸器,管理水泥量和时间,温和地注入水泥,并了解水泥的扩散.
- 还提供了关于窗户外螺丝拆除的具体指导.
结论:
- 实施前面所介绍的10个技巧可以显著提高水泥增强窗口脚螺丝技术的性能.
- 遵守这些准则预计将尽量减少手术并发症并改善患者的治疗结果.
更多相关视频
相关概念视频
Cavity Drainage and Flashings in Masonry walls
Typically, a cavity wall consists of two wythes separated by a gap of at least 2 inches, which may contain insulation while still maintaining a minimum clear space of 1 inch to facilitate adequate drainage. Advanced methods like the insertion of a continuous drainage mat can further reduce this space while ensuring effective moisture expulsion.
Weep holes, strategically placed at the base of the cavity, are critical for draining accumulated water. These openings are created by leaving head...
Weep holes, strategically placed at the base of the cavity, are critical for draining accumulated water. These openings are created by leaving head...
Efflorescence in Masonry
Efflorescence in masonry walls appears as a fluffy crystalline powder, often white, resulting from water-soluble salts within the masonry or mortar. When water penetrates the masonry, it dissolves these salts and brings them to the surface, where they are deposited upon evaporation of water.
While initial efflorescence is common post-construction and can be cleaned with water and a brush, in certain instances, efflorescence can reappear and gradually diminish over time as salts are leached out...
While initial efflorescence is common post-construction and can be cleaned with water and a brush, in certain instances, efflorescence can reappear and gradually diminish over time as salts are leached out...
Bleeding in Fresh Concrete
Bleeding in fresh concrete occurs when water from the mix rises to the surface. This happens because the mix's solid components fail to retain all the water as they settle, leading to separation where water collects at the top. The severity of bleeding can be measured by assessing the total settlement or by noting the decrease in height per unit height of concrete.
Bleeding can cause several issues in the concrete structure. Sometimes, the rising water gets trapped beneath large aggregate...
Bleeding can cause several issues in the concrete structure. Sometimes, the rising water gets trapped beneath large aggregate...
Curing Methods
Concrete members with a small surface-to-volume ratio are cured by oiling and moistening the forms before casting the concrete member. These forms can be left in place for a prolonged period to prevent moisture loss, and can be wetted if made of a material suitable for wetting. If the forms are removed early, the concrete member is moistened and covered with polythene sheets to maintain moisture. For large horizontal concrete surfaces exposed to dry weather, a temporary covering is suspended...
Waterproofing and Anti-Bacterial Admixtures in Concrete
Concrete's susceptibility to water absorption is due to the capillary action within the pores of its hydrated cement paste. This action draws water in, creating the need for waterproofing admixtures to prevent such penetration. The efficacy of these admixtures is contingent upon the water pressure, with variations arising from different conditions such as rain, capillary rise, or hydrostatic pressure in structures intended to hold water.
Waterproofing admixtures render concrete hydrophobic,...
Waterproofing admixtures render concrete hydrophobic,...
Mortar Joint Deterioration in Masonry
Mortar joint deterioration is a significant concern in masonry structures, with water accumulation in the joints leading to damage from freeze-thaw cycles. The repeated expansion of water during freezing and its melting during thawing develop and propagate cracks in the masonry joints. Eventually, this leads to the spalling of mortar from the joints, loosening masonry units and weakening the structure. The deteriorated mortar joints are also vulnerable to moisture intrusion into the walls.
The...
The...


