基于PCA和SSA-LightGBM的浸油变压器故障诊断方法
Jizhong Wang1, Jianfei Chi1, Yeqiang Ding1
1State Grid Zhejiang Electric Power Co., Ltd., Hangzhou, China.
PloS one
|February 19, 2025
概括
本研究引入了一种新的故障诊断方法,用于油浸式变压器,使用主要组件分析和SSA-LightGBM. 优化的模型达到93.6%的准确性,显著改善了变压器故障检测.
科学领域:
- 电气工程 电气工程
- 电力系统 电力系统
- 机器学习应用 机器学习应用
背景情况:
- 浸油变压器的复杂故障降低了诊断的准确性.
- 当前的诊断方法与复杂的故障模式作斗争.
研究的目的:
- 为浸油变压器开发准确有效的故障诊断方法.
- 通过先进的机器学习技术来提高诊断性能.
主要方法:
- 从浸油变压器收集的溶解气体数据.
- 构建了一个17维的故障特征矩阵并将其标准化.
- 应用主要组件分析 (PCA) 用于特征融合.
- 使用SSA-LightGBM开发和优化了一个变压器诊断模型.
- 通过十倍交叉验证验证模型.
主要成果:
- 在优化后,SSA-LightGBM模型实现了93.6%的平均故障诊断准确度.
- 优化的SSA-LightGBM显示比未优化的模型有3.6%的改进.
- SSA-LightGBM的表现优于GA-LightGBM (8.1%的改善) 和GWO-LightGBM (5.7%的改善).
结论:
- 拟议的SSA-LightGBM方法有效地提高了油浸式变压器的故障诊断性能.
- 与其他当代故障诊断模型相比,这种方法显示出更高的准确性.
- 集成PCA和SSA-LightGBM为变压器故障检测提供了一个强大的解决方案.
更多相关视频
04:35Author Spotlight: Simulation and Analysis of the Temperature Rise of Ring Main Unit Equipment
Published on: July 5, 2024
1.7K
10:52Design, Instrumentation and Usage Protocols for Distributed In Situ Thermal Hot Spots Monitoring in Electric Coils using FBG Sensor Multiplexing
Published on: March 8, 2020
5.8K
相关概念视频
Power System Three-Phase Short Circuits
72
Determining the subtransient fault current in a power system involves representing transformers by their leakage reactances, transmission lines by their equivalent series reactances, and synchronous machines as constant voltage sources behind their subtransient reactances. In this analysis, certain elements are excluded, such as winding resistances, series resistances, shunt admittances, delta-Y phase shifts, armature resistance, saturation, saliency, non-rotating impedance loads, and small...
72
Three-Phase Short Circuit—Unloaded Synchronous Machine
110
Conducting a three-phase short circuit test on an unloaded synchronous machine helps understand its impact on the system. The AC fault current's oscillogram, with the DC offset removed, reveals that the waveform amplitude decreases from an initially high value to a steady-state level for one phase of the machine.
This behavior occurs due to the magnetic flux produced by the short-circuit armature currents. Initially, these currents follow high-reluctance paths but eventually shift to...
This behavior occurs due to the magnetic flux produced by the short-circuit armature currents. Initially, these currents follow high-reluctance paths but eventually shift to...
110
Equivalent Circuits for Practical Transformers
379
The practical equivalent circuits of single-phase two-winding transformers exhibit significant deviations from their idealized versions due to the inherent properties of winding resistance and finite core permeability. These properties result in real and reactive power losses, affecting the transformer's performance. Understanding these deviations is crucial for designing more efficient transformers.
In a practical transformer, each winding exhibits resistance and leakage reactance. The...
In a practical transformer, each winding exhibits resistance and leakage reactance. The...
379
Transformers in Distribution System
98
Transformers in distribution systems can be broadly categorized into distribution substation transformers and other distribution transformers. They are crucial for stepping down high transmission voltages to levels suitable for distribution and end-user applications.
Distribution substation transformers come in various ratings and typically use mineral oil for insulation and cooling. To prevent moisture and air from entering the oil, some transformers use an inert gas like nitrogen to fill the...
Distribution substation transformers come in various ratings and typically use mineral oil for insulation and cooling. To prevent moisture and air from entering the oil, some transformers use an inert gas like nitrogen to fill the...
98
Three-Winding Transformers
187
Three identical single-phase transformers can be configured to form a three-phase transformer connection, which involves high-voltage and low-voltage windings. The high-voltage windings are denoted by capital letters A-B-C, while the low-voltage windings are labeled with lowercase letters a-b-c, representing their respective phases. This notation helps distinguish between the high and low voltage sides of the transformer.
In the per-unit equivalent circuit of a grounded Y-Y three-phase...
In the per-unit equivalent circuit of a grounded Y-Y three-phase...
187
Transformers with Off-Nominal Turns Ratios
131
In scenarios involving parallel transformers with disparate ratings, developing per-unit models requires accommodating off-nominal turns ratios. This situation arises when the selected base voltages are not proportional to the transformer’s voltage ratings. Consider a transformer where the rated voltages are related by the term a. If the chosen voltage bases satisfy a relationship involving term b, term c is defined as the ratio of these bases. This ratio is then substituted into the...
131