在不同高度对空气温度的被动声学测量
Yan Yue1,2, Zhi-Mei Qi1,2,3, Tao Qiao1
1State Key Laboratory of Transducer Technology, Aerospace Information Research Institute, Chinese Academy of Sciences, Beijing 100190, China.
The Journal of the Acoustical Society of America
|February 19, 2025
概括
被动声学温度计可在高海拔地区实时监测空气温度. 这种声学Fabry-Perot共振器 (AFPR) 方法使用环境噪声准确地测量温度,在环境研究中证明可靠.
科学领域:
- 物理 物理学 物理
- 环境科学 环境科学
- 传感器技术 传感器技术
背景情况:
- 由于空气稀薄和热平衡的挑战,传统的温度计在高海拔地区难以实时监测温度.
- 对于动态的环境条件,需要非接触式温度测量方法.
研究的目的:
- 开发和验证一种被动声学温度计,用于在高海拔地区实时测量空气温度.
- 在各种环境中评估Fabry-Perot声学共振器 (AFPR) 方法的可靠性和准确性.
主要方法:
- 使用了一种被动声学温度计 (AFPR),包括一个电极冷凝器麦克风和声波导.
- 使用环境白噪声测量了AFPR的共振频率 (fR),并从fR与模式顺序号 (m) 的斜率中确定温度.
- 在北京和喀什高原进行实时测量,并在挂着的气球上进行测试,以进行垂直分析.
主要成果:
- 实现了高达5200米的实时空气温度测量.
- 在不同地点连续监控15个小时的可靠性能.
- 与商用电子温度计相比,观察到的平均偏差小于0.5°C. 与商用电子温度计相比.
结论:
- 基于AFPR的被动声学温度计是一种可靠和准确的实时空气温度监测方法,特别是在具有挑战性的高海拔环境中.
- 这项技术为环境监测和大气研究提供了可行的替代方案.
相关概念视频
Temperature Measurement Sites
1.5K
A thermometer measures body temperature. The common sites for measuring body temperature are the oral cavity, axillary region, temporal artery, and skin surface, such as the forehead, abdomen, and axilla. True core body temperature is assessed in the rectum, tympanic membrane, pulmonary artery, esophagus, and urinary bladder.
Oral: When assessing oral temperature, the thermometer tip should be placed under the tongue in the posterior sublingual pocket. It offers accurate readings and can be...
Oral: When assessing oral temperature, the thermometer tip should be placed under the tongue in the posterior sublingual pocket. It offers accurate readings and can be...
1.5K
Equipments Used to Measure Body Temperature
951
Body temperature can be assessed using various devices and measured in Celsius or Fahrenheit.
Glass-bulb Thermometer:
Glass-bulb thermometers are hollow glass tubes with a bulb tip containing liquid such as ethanol or mercury. Historically, glass bulb mercury thermometers were the standard device to measure body temperature. Today, mercury thermometers are prohibited in many countries due to the hazardous effects of mercury and the risk of exposure if the glass bulb breaks. In general,...
Glass-bulb Thermometer:
Glass-bulb thermometers are hollow glass tubes with a bulb tip containing liquid such as ethanol or mercury. Historically, glass bulb mercury thermometers were the standard device to measure body temperature. Today, mercury thermometers are prohibited in many countries due to the hazardous effects of mercury and the risk of exposure if the glass bulb breaks. In general,...
951
Variation of Atmospheric Pressure
2.0K
Change in atmospheric pressure with height is particularly interesting. The decrease in atmospheric pressure with increasing altitude is due to the decreasing gravitational force per unit area as we move away from the surface of the earth.
Assuming the air temperature is constant at a given altitude and that the ideal gas law of thermodynamics describes the atmosphere to a good approximation, one can find the variation of atmospheric pressure with height.
Let p(y) be the atmospheric pressure at...
Assuming the air temperature is constant at a given altitude and that the ideal gas law of thermodynamics describes the atmosphere to a good approximation, one can find the variation of atmospheric pressure with height.
Let p(y) be the atmospheric pressure at...
2.0K
Pressure and Volume in an Adiabatic Process
2.6K
Free expansion of a gas is an adiabatic process. However, there are few differences between free expansion and adiabatic expansion. During free expansion, no work is done, and there is no change in internal energy. But, for an adiabatic expansion, work is done, and there is a change in internal energy. During an adiabatic process, the relation between the pressure and volume is obtained from the condition for the adiabatic process, that is,
2.6K
Assessing Body Temperature - Temporal Artery
514
Here is a stepwise guide to assessing the body temperature at the temporal artery using a temporal artery thermometer
Step 1: Perform hand hygiene and don a fresh pair of gloves to prevent cross-infection and ensure patient safety.
Step 2: Explain the procedure to the patient to establish trust. Clear communication establishes trust with the patient, ensures they understand what to expect, promotes cooperation, and enhances comfort during the procedure.
Step 3: Assess the patient's...
Step 1: Perform hand hygiene and don a fresh pair of gloves to prevent cross-infection and ensure patient safety.
Step 2: Explain the procedure to the patient to establish trust. Clear communication establishes trust with the patient, ensures they understand what to expect, promotes cooperation, and enhances comfort during the procedure.
Step 3: Assess the patient's...
514
Atomic Spectroscopy: Effects of Temperature
279
Atomization, converting samples into gas-phase atoms and ions, is essential for atomic spectroscopy. The flame temperature required for atomization affects the efficiency of the atomic spectroscopic methods by increasing the atomization efficiency and the relative population of the excited and ground states.
At thermal equilibrium, the relative populations of excited and ground state atoms can be estimated using the Maxwell–Boltzmann distribution. For example, an increase in temperature...
At thermal equilibrium, the relative populations of excited and ground state atoms can be estimated using the Maxwell–Boltzmann distribution. For example, an increase in temperature...
279