在超临界水中增强的燃烧,由水下电气爆炸引起
1Beijing Institute of Technology, State Key Laboratory of Explosion Science and Safety Protection, Beijing 100081, China.
Physical review. E
|February 20, 2025
概括
水下爆炸泡触发了超临界水中的燃烧. 这项研究分析了泡动力学和光辐射,揭示了在极端水力动力学条件下金属燃烧的洞察力.
科学领域:
- 物理化学 物理化学
- 材料科学 材料科学 材料科学
- 流体动力学 流体动力学
背景情况:
- 在超临界水中金属的燃烧是很少理解的.
- 水下爆炸泡造成极端条件 (高温和高压).
研究的目的:
- 为了研究由水下爆炸泡产生的超临界水引起的燃烧.
- 分析燃烧过程中泡振荡和光辐射的动态.
主要方法:
- 通过在水箱中的线的电放电启动水下爆炸泡.
- 记录气泡半径振荡和光辐射.
- 观察由于水力动力学不稳定性而导致的发光停止.
主要成果:
- 在压缩泡中实现了超临界水条件.
- 观察到微型颗粒的强烈点火.
- 发光辐射持续了近一毫秒,与蒸汽-液体界面流相关.
结论:
- 水下爆炸泡可以有效地诱导超临界水中的金属燃烧.
- 水力动力学不稳定性在燃烧动力学和排放特性中起作用.
- 这项研究为研究极端条件下的复杂反应系统提供了基础.
相关概念视频
Atomic Emission Spectroscopy: Interference
160
In atomic emission spectroscopy (AES), high-temperature atomizers excite a broad range of elements and molecules that generate complex emissions from sources such as oxides, hydroxides, and flame combustion products in the flame or plasma. Several strategies can be employed to minimize spectral interferences caused by overlapping emission lines or bands. These include increasing instrument resolution, choosing alternative emission lines, optimally placing the detector in low-background regions,...
160
Atomic Emission Spectroscopy: Overview
1.4K
Atomic emission spectroscopy (AES) is an analytical technique used to determine the elemental composition of a sample by analyzing the light emitted from excited atoms. In AES, atoms in a sample are excited to higher energy levels by thermal energy from high-temperature sources, such as plasma, arcs, or sparks. When these excited atoms return to lower energy states, they emit light at specific wavelengths characteristic of each element. The resulting atomic emission spectrum, which consists of...
1.4K
Atomic Absorption Spectroscopy: Atomization Methods
345
Atomic Absorption Spectroscopy (AAS) atomizes samples through flame atomization or electrothermal atomization. Flame atomization typically involves a nebulizer and spray chamber assembly to combine the sample with a fuel–oxidant mixture, creating a fine aerosol mist that enters a burner. Typically, the fuel and oxidant are combined in an approximately stoichiometric ratio. However, for atoms that are easily oxidized, a fuel-rich mixture may be more advantageous. Only about 5% of the...
345