通过可靠的物联网协调资产,提高电网的弹性
Vineet J Nair1, Priyank Srivastava2, Venkatesh Venkataramanan3
1Department of Mechanical Engineering, MIT, Cambridge, MA 02139.
概括
本研究引入了一个框架,通过使用当地市场协调分布式能源 (DER) 来提高电网对网络攻击的弹性. 这种方法通过利用可信的本地资产来缓解风险,确保了电网稳定性.
科学领域:
- 电气工程 电气工程
- 计算机科学 计算机科学
- 网络安全 网络安全
背景情况:
- 电网正在转变为网络物理系统,增加对网络攻击的脆弱性.
- 分布式能源 (DER) 提供了效率提升,但也带来了新的安全挑战.
- 在网络威胁日益增加的情况下,确保电网弹性至关重要.
研究的目的:
- 提出一个框架,以提高电网对网络攻击的抵御力.
- 为了提高电网安全,利用协调分布式能源 (DERs).
- 建立一个当地电力市场,以协调资产和评估可靠性.
主要方法:
- 开发了一个使用物联网 (IoT) 设备网络协调DER的框架.
- 提出了地方电力市场,以确定和管理可信资产.
- 实施了资产可靠性和承诺的监控程序.
- 使用了高保真度共模拟平台,实时硬件在循环中的验证,以及一个实用友好的模拟器进行演示.
主要成果:
- 通过使用本地协调和可信赖的DERs,证明了各种网络攻击的缓解.
- 展示了保持电网稳定性的能力,而不会对散装电网造成压力.
- 通过多次高保真模拟和实时硬件测试来验证拟议的框架.
结论:
- 拟议的框架有效地提高了电网对网络攻击的抵御力.
- 地方电力市场可用于协调DER并确保电网安全.
- 对值得信赖的DER的情境意识是缓解网络威胁和保持电网稳定的关键.
相关概念视频
Distribution Reliability and Automation
103
Distribution reliability in electrical power systems is critical for ensuring an uninterrupted power supply to consumers at minimal cost. According to IEEE Standard Terms, reliability is the probability that a device will function without failure over a specified time period or amount of usage. For electric power distribution, this translates to maintaining continuous power supply and addressing customer concerns over power outages. Several indices, as defined by IEEE Standard 1366-2012, are...
103
Line Protection with Impedance Relays
64
Coordinating time-delay overcurrent relays in complex radial systems and directional overcurrent relays in multi-source transmission loops can be challenging. Impedance relays address these issues by responding to the voltage-to-current ratio, specifically measuring the apparent impedance of a line. These relays become more sensitive during faults as current increases and voltage decreases, thereby reducing the apparent impedance.
Under normal conditions, low load currents keep the measured...
Under normal conditions, low load currents keep the measured...
64
Reclosers and Fuses
78
Automatic circuit reclosers enhance the protection of distribution circuits by interrupting and auto-reclosing an AC circuit according to a preset sequence. They effectively manage temporary faults on overhead distribution lines, often caused by tree limbs or wildlife, by briefly disrupting service to improve overall reliability. However, contact with reclosers or energized broken conductors on the ground can pose serious hazards.
A comprehensive protection scheme for radial distribution...
A comprehensive protection scheme for radial distribution...
78
Zones of Protection
129
In power systems, the entire setup is divided into protective zones to isolate faults and protect the rest of the network. These zones include generators, transformers, buses, transmission lines, distribution lines, and motors. Each zone can be visualized as a separate room in a house, with each room protected by its own circuit breaker.
Protective zones are defined by closed dashed lines, containing one or more components. A key characteristic of these zones is the strategic placement of...
Protective zones are defined by closed dashed lines, containing one or more components. A key characteristic of these zones is the strategic placement of...
129
Power System Distribution
225
Power system distribution involves delivering electrical energy from power plants to consumers through a network of transmission and distribution systems. The process begins at power plants, where energy from coal, gas, nuclear, water, and wind is converted into electrical energy. These plants use three-phase generators, typically rated between 50 to 1300 MVA, with terminal voltages ranging from a few kV to 20 kV, depending on the size and age of the units.
The transmission system is designed...
The transmission system is designed...
225
Distributed Loads
495
Distributed loads are a common type of load that engineers and scientists encounter in various practical situations. Distributed loads often refer to a type of load spread over a surface or a structure and can be modeled as continuous force per unit area.
For example, consider a bookshelf filled with books stacked vertically adjacent to each other. The weight of the books is evenly distributed over the length of the shelf. As a result, the pressure at different locations on the surface of the...
For example, consider a bookshelf filled with books stacked vertically adjacent to each other. The weight of the books is evenly distributed over the length of the shelf. As a result, the pressure at different locations on the surface of the...
495