使用EDTA和CaCl2提取方法来预测受微塑料污染的土壤中的重金属的生物可用性
Bhakti Jadhav1, Agnieszka Medyńska-Juraszek1
1Institute of Soil Science, Plant Nutrition and Environmental Protection, Wroclaw University of Environmental and Life Sciences, 53 Grunwaldzka Str., 50-357 Wrocław, Poland.
Materials (Basel, Switzerland)
|February 26, 2025
概括
不同的微塑料 (MPs) 显著改变土壤pH值和重金属 (HM) 流动性和生物可用性. HDPE降低了的流动性,同时增加了和的流动性,影响了土壤的健康和修复.
科学领域:
- 环境科学 环境科学
- 土壤科学 土壤科学
- 地质化学 地质化学
背景情况:
- 土壤微塑料 (MP) 污染是一个日益严重的环境问题.
- 国会议员影响土壤生态系统中重金属 (HM) 的流动性和生物可用性.
研究的目的:
- 研究各种微塑料类型 (PP,PS,PVC,HDPE,LDPE,PES,PET-Glitter) 对土壤中重金属行为的影响.
- 评估Pb,Cu,Co,Ni,Cr和Cd对吸/脱和提取效率的影响.
主要方法:
- 用不同的MP化土壤样本.
- 测量土壤pH值的变化.
- 使用EDTA和CaCl2.2的提取实验.
- 批量吸附试验. 批量吸附试验.
主要成果:
- MPs导致土壤pH值显著增加 (例如,PES增加0.8个,HDPE增加0.6个pH单位).
- 高密度 HDPE 减少了 15% 的流动性,但增加了 10-20% 的和流动性.
- 与对照组相比,HDPE的Pb吸附率较高,而Cd和Cos吸附率降低.
结论:
- 微塑料充当了额外的吸附点,改变了土壤中的重金属物种和可用性.
- 这些发现对土壤健康,农业可持续性和补救策略有重大影响.
- 由于土壤类型,MP老化和环境条件的潜在变化,需要进行进一步的长期实地研究.
相关概念视频
EDTA: Direct, Back-, and Displacement Titration
2.3K
The EDTA titration types for metal ion analysis include direct titration, back-titration, and replacement titration.
Direct titration involves buffering the metal ion solution to the desired pH and directly titrating with standard EDTA until the endpoint. The optimum pH ensures a large conditional formation constant of metal−EDTA and visibility of the free indicator color in the solution. In addition, auxiliary complexing reagents are used to prevent the precipitation of metal hydroxides...
Direct titration involves buffering the metal ion solution to the desired pH and directly titrating with standard EDTA until the endpoint. The optimum pH ensures a large conditional formation constant of metal−EDTA and visibility of the free indicator color in the solution. In addition, auxiliary complexing reagents are used to prevent the precipitation of metal hydroxides...
2.3K
Masking and Demasking Agents
2.3K
EDTA titrations may necessitate masking and demasking agents to temporarily protect a particular metal ion in a mixture from the EDTA reaction. These agents facilitate the sequential analysis of the metal ions by forming stable complexes with some—but not all—metal ions during certain steps.
There are many masking agents, such as cyanide, fluoride, triethanolamine, thiourea, and 2,3-bis(sulfanyl)propan-1-ol (formerly 2,3-dimercapto-1-propanol), with the masking agent chosen based on...
There are many masking agents, such as cyanide, fluoride, triethanolamine, thiourea, and 2,3-bis(sulfanyl)propan-1-ol (formerly 2,3-dimercapto-1-propanol), with the masking agent chosen based on...
2.3K
EDTA: Auxiliary Complexing Reagents
526
EDTA titrations are usually carried out in highly basic conditions, where the fully deprotonated form of EDTA, Y4−, actively complexes with the free metal ions in the solution. Several metal ions precipitate as hydrous oxide (hydroxides, oxides, or oxyhydroxides) under these conditions, lowering the concentration of free metal ions in the solution. For this reason, auxiliary complexing agents or ligands such as ammonia, tartrate, citrate, or triethanolamine are used in EDTA titrations to...
526
EDTA: Chemistry and Properties
1.7K
Polydentate ligands are most widely used in complexometric titrations because they form more stable complexes with the metal ions than mono- or bidentate ligands due to the chelate effect. Examples of polydentate ligands are ethylenediaminetetraacetic acid (EDTA), crown ethers, and cryptands. The most important feature of optimal polydentate ligands is the ability to form 1:1 complexes in a single-step process. Amino carboxylic acid derivatives are frequently used as complexing agents. EDTA is...
1.7K
EDTA: Indirect and Alkalimetric Titration
795
Unlike direct titration, back-titration, and displacement titration, indirect titration is an EDTA titration method for quantifying anions. In the indirect titration method, anions are precipitated as their insoluble salts with excess metal ions. The filtrate containing the excess metal ions is directly titrated with standard EDTA until the endpoint is achieved. Another approach involves extracting the metal ion and back-titrating with standard EDTA to obtain the endpoint. In this way, the...
795
Effects of EDTA on End-Point Detection Methods
239
Different methods, such as visual observance of metal-ion indicators, spectroscopic techniques, and potentiometric methods, can determine the endpoint of an EDTA titration.
In the visual method, metal-ion indicators (metallochromic dyes), which have distinct colors in their free and complex forms, are added to the mixture to signal the titration's end point. They form stable complexes with metal ions, but these complexes are weaker than the corresponding metal–EDTA complexes. As a...
In the visual method, metal-ion indicators (metallochromic dyes), which have distinct colors in their free and complex forms, are added to the mixture to signal the titration's end point. They form stable complexes with metal ions, but these complexes are weaker than the corresponding metal–EDTA complexes. As a...
239


