功率变压器故障诊断方法基于多源信号融合和快速光谱相关性
Shan Guan1, Mingyu Shi2, Fuwang Wang1
1School of Mechanic Engineering, Northeast Electric Power University, Jilin, 132012, China.
Scientific reports
|February 26, 2025
概括
这项研究引入了一种新的电力变压器故障诊断方法,使用多源振动信号融合和快速光谱相关性. 与传统方法相比,先进的技术显著提高了故障识别的准确性.
科学领域:
- 电气工程 电气工程
- 信号处理 信号处理
- 人工智能的人工智能
背景情况:
- 单个传感器测量提供不完整的功率变压器故障状态描述.
- 手动经验往往决定了故障诊断的信号特征的选择,引入了主观性.
研究的目的:
- 开发一种先进的电力变压器故障诊断方法.
- 为了克服单个传感器分析和手动功能选择的局限性.
主要方法:
- 从变压器外上的多个传感器同步收集振动信号.
- 使用关联函数权重的多源信号的融合.
- 应用快速光谱相关性来生成图像样本.
- 使用转移学习进行故障分类,训练一个MobileNetV3模型.
主要成果:
- 拟议的方法实现了98.75%的整体识别准确度.
- 这比单个传感器诊断有10.52%的改进.
- 它还显示了10.86%的改善与其他经典的基于图像的诊断相比.
结论:
- 开发的方法为电力变压器故障诊断提供了强大而准确的工具.
- 多源信号融合和快速光谱相关性增强了诊断能力.
- 这种方法为使用振动信号监测变压器健康提供了一种新的解决方案.
更多相关视频
11:54Microfluidic Platform with Multiplexed Electronic Detection for Spatial Tracking of Particles
Published on: March 13, 2017
9.2K
06:45Design and Application of a Fault Detection Method Based on Adaptive Filters and Rotational Speed Estimation for an Electro-Hydrostatic Actuator
Published on: October 28, 2022
1.5K
相关概念视频
Power System Three-Phase Short Circuits
72
Determining the subtransient fault current in a power system involves representing transformers by their leakage reactances, transmission lines by their equivalent series reactances, and synchronous machines as constant voltage sources behind their subtransient reactances. In this analysis, certain elements are excluded, such as winding resistances, series resistances, shunt admittances, delta-Y phase shifts, armature resistance, saturation, saliency, non-rotating impedance loads, and small...
72
Three-Phase Short Circuit—Unloaded Synchronous Machine
110
Conducting a three-phase short circuit test on an unloaded synchronous machine helps understand its impact on the system. The AC fault current's oscillogram, with the DC offset removed, reveals that the waveform amplitude decreases from an initially high value to a steady-state level for one phase of the machine.
This behavior occurs due to the magnetic flux produced by the short-circuit armature currents. Initially, these currents follow high-reluctance paths but eventually shift to...
This behavior occurs due to the magnetic flux produced by the short-circuit armature currents. Initially, these currents follow high-reluctance paths but eventually shift to...
110
Instrument Transformers
64
Instrument transformers, comprising voltage transformers (VTs) and current transformers (CTs), play crucial roles in power substations by providing isolated replicas of current or voltage for measurement and protection purposes. Voltage transformers reduce the primary voltage to levels suitable for relay operation and measurement, while current transformers scale down the primary current. The primary winding of a current transformer often consists of a single turn, achieved by threading the...
64
Fault Types
64
When analyzing a single line-to-ground fault from phase A to ground at a three-phase bus, it is important to consider the fault impedance. This impedance is zero for a bolted fault, equal to the arc impedance for an arcing fault, and represents the total fault impedance for a transmission-line insulator flashover. To derive sequence and phase currents, fault conditions are translated from the phase domain to the sequence domain.
For line-to-line faults occurring between phases B and C, the...
For line-to-line faults occurring between phases B and C, the...
64
Energy Losses in Transformers
819
In an ideal transformer, it is assumed that there are no energy losses, and, hence, all the power at the primary winding is transferred to the secondary winding. However, in reality, the transformers always have some energy losses, and, hence, the output power obtained at the secondary winding is less than the input power at the primary winding due to energy losses.
There are four main reasons for energy losses in transformers.
The first cause can be the high resistance of the...
There are four main reasons for energy losses in transformers.
The first cause can be the high resistance of the...
819
Bus Impedance Matrix
98
Calculating subtransient fault currents for three-phase faults in an N-bus power system involves using the positive-sequence network. When a three-phase short circuit occurs at a specific bus, the analysis uses the superposition method to evaluate two separate circuits.
In the first circuit, all machine voltage sources are short-circuited, leaving only the prefault voltage source at the fault location. The positive-sequence bus impedance matrix can be determined by solving the nodal equations,...
In the first circuit, all machine voltage sources are short-circuited, leaving only the prefault voltage source at the fault location. The positive-sequence bus impedance matrix can be determined by solving the nodal equations,...
98