MSConnect:开源,端到端的平台,用于自动化质谱数据管理,分析和可视化
Xiaofeng Xie1, Parker S Reyes2, Hsien-Jung L Lin2
1MicrOmics Technologies, LLC, Spanish Fork, Utah 84660, United States.
Journal of proteome research
|February 28, 2025
概括
MSConnect简化了复杂的质谱蛋白质组学数据分析. 这个集成的平台增强了工作流的可重复性,并为omics研究人员自动化了从数据收集到可视化的步骤.
科学领域:
- 蛋白质组学是指蛋白质组学.
- 生物信息学是一种生物信息学.
- 数据科学数据科学数据科学
背景情况:
- 基于质谱的蛋白质组学数据集正在扩大规模.
- 当前分析工作流涉及多个,通常是不同的软件程序.
- 在这些程序中手动处理数据容易出现错误,劳动密集型,并妨碍可重复性.
研究的目的:
- 为基于质谱 (MS) 的蛋白质组学开发一个集成的数据管理和分析平台.
- 为了提高复杂的蛋白质组学数据处理工作流程的简单性,可追溯性和可重复性.
- 自动化常见的备份和分析步骤,从数据收集到总结和可视化.
主要方法:
- 开发MSConnect,一个集成的数据管理和分析平台.
- 在多个软件程序中实现可追溯的处理工作流.
- 设计允许无集成第三方工具和定制工作流程自动化.
主要成果:
- MSConnect简化并使大规模蛋白质组学数据的处理可追溯.
- 该平台自动化了常见的数据处理,备份和分析步骤.
- 它提高了工作流的可重复性,并减少了手工劳动和错误.
结论:
- MSConnect提供了一个统一的解决方案,用于管理和分析基于MS的复杂蛋白质组学数据.
- 它的开放性质促进了各种工具和定制工作流的社区集成.
- 该平台有可能成为一个社区驱动的资源,为omics研究人员.
更多相关视频
09:29Using the Open-Source MALDI TOF-MS IDBac Pipeline for Analysis of Microbial Protein and Specialized Metabolite Data
Published on: May 15, 2019
19.3K
07:38Mass Spectrometry-Based Proteomics Analyses Using the OpenProt Database to Unveil Novel Proteins Translated from Non-Canonical Open Reading Frames
Published on: April 11, 2019
12.7K
相关概念视频
Mass Spectrometry: Overview
8.2K
Mass spectrometry is an analytical technique used to determine the molecular mass and molecular formula of a compound. The basic principle of mass spectrometry is to generate ions from the analyte molecule and measure these ion abundances against their molecular mass. One common type of ionization, known as electron ionization or EI, bombards the analyte molecules in the gas phase with high-energy electron beams. The electron beams displace an electron from the molecule and leave behind a...
8.2K
Mass Spectrometers
9.6K
This lesson details the instrumentation of a mass spectrometer—a physical instrument to perform mass spectrometry on analyte molecules and record the characteristic mass spectra. This is achieved via three chief functions:
9.6K
MALDI-TOF Mass Spectrometry
5.8K
Mass spectrometry is a powerful characterization technique that can identify and separate a wide variety of compounds ranging from chemical to biological entities, based on their mass-to-charge ratio (m/z). The instruments that allow this detection, known as mass spectrometers, have three components: an ion source, a mass analyzer, and a detector. These spectrometers differ based on the nature of their ion source and analyzers.Matrix-assisted laser desorption ionization (MALDI) is a commonly...
5.8K
Peptide Identification Using Tandem Mass Spectrometry
6.2K
Tandem mass spectrometry, also known as MS/MS or MS2, is an analytical technique that employs two mass analyzers. Essentially it is a series of mass spectrometers that helps isolate a particular biomolecule and then helps study its chemical properties.
This technique helps gather information regarding the protein from which the peptide was obtained and to study the peptides’ amino acid sequence. Identifying peptides from a complex mixture is an important component of the growing field of...
This technique helps gather information regarding the protein from which the peptide was obtained and to study the peptides’ amino acid sequence. Identifying peptides from a complex mixture is an important component of the growing field of...
6.2K
Mass Spectrometry: Complex Analysis
2.1K
Mass spectrometry is an important technique for the identification of pure compounds. However, it has some limitations for the analysis of complex mixtures, often due to excessive fragmentation making the spectrum too complicated to decipher. Mass spectrometry can be combined with suitable separation methods in sequence, forming hyphenated methods, which are useful in the analysis of complex mixtures.
GC–MS is a powerful hyphenated method commonly used in forensics and environmental...
GC–MS is a powerful hyphenated method commonly used in forensics and environmental...
2.1K
Tandem Mass Spectrometry
3.0K
Tandem mass spectrometry is a technique that uses multiple mass analyzers in series to obtain a higher selectivity and reduce chemical noise during analyte detection. Instruments with multiple analyzers separated by an interaction cell enable secondary fragmentation and selected study of the fragment ions.Secondary fragmentations occur in the interaction cell and can be induced by various factors. Fragmentation induced by collision with inert gases, such as N2, Ar, He, etc., is called...
3.0K