基于能源供应分级策略的多存储组合综合能源系统的最佳调度研究
Na Zhang1,2, Feng You3,4, Bingqian Hu3,5
1Engineering Research Center of Large Energy Storage Technology, Ministry of Education, Inner Mongolia, Hohhot, 010000, China. zhangna2010337@163.com.
Scientific reports
|February 28, 2025
概括
将储能集成到多储能能源系统中,可以提高碳中和的灵活性. 一个分层的控制策略可以降低运营和碳成本,帮助实现可再生能源的整合.
科学领域:
- 能源系统工程 能源系统工程
- 整合可再生能源的整合
- 碳中立技术 碳中立技术
背景情况:
- 为了实现碳中和,需要先进的能源解决方案.
- 综合能源系统需要提高多能源合的灵活性.
- 储存是一种支持低碳发展的关键技术.
研究的目的:
- 开发一个多存储集成能源系统架构 (电,热,).
- 提出一个层次化的能源供应控制战略,以优化储能单元的优先级.
- 构建一个全面的能源优化调度模型.
主要方法:
- 建立了一个多存储集成能源系统架构.
- 根据系统状态制定了基于系统状态的层次能源供应控制策略.
- 使用NSGA-II-MOABC算法来优化多能合.
- 构建了一个优化模型,考虑了运营和碳排放成本.
主要成果:
- 集成储能系统显著提高了能源系统调度的灵活性.
- 层次化的能源供应战略有效地降低了系统运行和碳排放成本.
- 拟议的战略表明在促进当地可再生能源消费方面发挥了作用.
结论:
- 具有储量的多存储系统对于灵活和低碳的综合能源解决方案至关重要.
- 层次控制策略优化能源调度,降低成本和排放.
- 这种方法支持利用可再生能源和碳中和的更广泛目标.
更多相关视频
05:30Large Scale Energy Efficient Sensor Network Routing Using a Quantum Processor Unit
Published on: September 8, 2023
472
10:36Author Spotlight: Optimization of Airflow Velocities in Battery Cooling Systems for Enhanced Thermal Performance and Reduced Energy Consumption
Published on: November 3, 2023
1.4K
相关概念视频
Secondary Distribution
75
Secondary distribution systems provide electrical energy at the utilization voltage levels from distribution transformers to customer meters. Typical secondary voltages in the United States include 120/240 V for residential use, 208Y/120 V for residential and commercial use, and 480Y/277 V for industrial and high-rise commercial use.
In residential areas, 120/240 V single-phase, three-wire service is commonly used for lighting, outlets, and large appliances. Urban areas with high-density loads...
In residential areas, 120/240 V single-phase, three-wire service is commonly used for lighting, outlets, and large appliances. Urban areas with high-density loads...
75
Transformers in Distribution System
98
Transformers in distribution systems can be broadly categorized into distribution substation transformers and other distribution transformers. They are crucial for stepping down high transmission voltages to levels suitable for distribution and end-user applications.
Distribution substation transformers come in various ratings and typically use mineral oil for insulation and cooling. To prevent moisture and air from entering the oil, some transformers use an inert gas like nitrogen to fill the...
Distribution substation transformers come in various ratings and typically use mineral oil for insulation and cooling. To prevent moisture and air from entering the oil, some transformers use an inert gas like nitrogen to fill the...
98
Power Distribution in Three-phase and Single Phase Circuits
287
Power distribution within electrical circuits is a foundational aspect of residential and industrial energy systems. While single-phase power is common in residential settings, three-phase power is the standard for industrial environments with heavy machinery. Each system is different and has advantages, and it's crucial to understand the underlying principles of power distribution and material efficiency.
Single-Phase Power Distribution:
Single-phase circuits are typical in household...
Single-Phase Power Distribution:
Single-phase circuits are typical in household...
287
Multimachine Stability
129
Multimachine stability analysis is crucial for understanding the dynamics and stability of power systems with multiple synchronous machines. The objective is to solve the swing equations for a network of M machines connected to an N-bus power system.
In analyzing the system, the nodal equations represent the relationship between bus voltages, machine voltages, and machine currents. The nodal equation is given by:
In analyzing the system, the nodal equations represent the relationship between bus voltages, machine voltages, and machine currents. The nodal equation is given by:
129
Load-frequency control
113
Load-frequency control (LFC) is vital for maintaining power system stability, ensuring that frequency and power flows remain within acceptable limits during load changes. Turbine-governor control eliminates rotor accelerations and decelerations following load changes. However, a steady-state frequency error persists when the change in the turbine-governor reference setting is zero. In an interconnected power system, each area agrees to export or import a scheduled amount of power through...
113
Primary Distribution
88
Primary distribution systems deliver electrical power from substations to consumers through various voltage classes, with 15-kV class voltages being predominant among U.S. utilities. Older 2.5- and 5-kV classes are being replaced by 15-kV primaries, while higher 25- to 34.5-kV classes are used in high-density urban areas and rural regions with long feeders. Three-phase, four-wire multigrounded systems are widely employed for balanced power delivery, using the neutral wire as a grounding point.
88