概括
高能电子在电子显微镜中损害生物分子. 在成像中提高剂量效率是最大限度地减少这种辐射损伤和提高图像质量的最现实的方法.
科学领域:
- 材料科学 材料科学 材料科学
- 生物物理学的生物物理.
- 显微镜的使用方法
背景情况:
- 生物分子容易受到高能电子的损伤,这是电子显微镜的一个重大局限.
- 这种辐射损伤限制了可用于成像微妙生物标本的电子暴露水平.
研究的目的:
- 在电子显微镜检查过程中,确定生物样本中辐射损伤的主要原因.
- 评估减轻辐射损伤和提高成像剂量效率的策略.
主要方法:
- 分析许多电子,体积等离子体激发作为放射溶解的主要原因.
- 审查目前和拟议的方法,以减少电子辐射在显微镜中的损害.
主要成果:
- 许多电子,体积等离子体激发迅速导致单电子电离和激发,被确定为损伤的主要来源.
- 许多减少初级放射溶解的方法是不切实际的或有缺陷的;提高剂量效率是最可行的策略.
结论:
- 提高图像记录的剂量效率是最小化电子显微镜中辐射损伤的最现实的方法.
- 对于传统和扫描电子显微镜来说,剂量效率的进展正在进行中,传统方法设定了一个基准.
更多相关视频
05:33Light-Induced In Situ Transmission Electron Microscopy for Observation of the Liquid-Soft Matter Interaction
Published on: July 26, 2022
2.1K
10:23Author Spotlight: A Machine-Vision Approach to Transmission Electron Microscopy Workflows, Results Analysis and Data Management
Published on: June 23, 2023
2.3K
相关概念视频
Preparation of Samples for Electron Microscopy
5.3K
To be visualized by an electron microscope, either transmission or scanning, biological samples need to be fixed (stabilized) so the electron beam does not destroy them and dried thoroughly (desiccated/dehydrated) so the vacuum does not affect them. Fixation needs to be done as quickly as possible because the sample properties will start changing as soon as it is removed from its natural environment. For example, in a tissue sample, the oxygen levels begin decreasing, causing an altered...
5.3K
Transmission Electron Microscopy
5.3K
In 1931, physicist Ernst Ruska—building on the idea that magnetic fields can direct an electron beam just as lenses can direct a beam of light in an optical microscope—developed the first prototype of the electron microscope. This development led to the development of the field of electron microscopy. In the transmission electron microscope (TEM), electrons are produced by a hot tungsten element and accelerated by a potential difference in an electron gun, which gives them up to 400...
5.3K
Scanning Electron Microscopy
4.1K
A scanning electron microscope (SEM) is used to study the surface features of a sample by using an electron beam that scans the sample surface in a two-dimensional manner. Typically, areas between ~1 centimeter to 5 micrometers in width can be imaged. SEM can be used to image bacteria, viruses, tissues as well as larger samples like insects. Conventional SEM gives a magnification ranging from 20X to 30,000X and spatial resolution of 50 to 100 nanometers.
Fundamental Principles
Accelerated...
Fundamental Principles
Accelerated...
4.1K
Overview of Electron Microscopy
8.5K
The wavelengths of visible light ultimately limit the maximum theoretical resolution of images created by light microscopes. Most light microscopes can only magnify 1000X, and a few can magnify up to 1500X. Electrons, like electromagnetic radiation, can behave like waves, but with wavelengths of 0.005 nm, they produce significantly greater resolution up to 0.05 nm as compared to 500 nm for visible light. An electron microscope (EM) can create a sharp image that is magnified up to 2,000,000X.
8.5K