静态和动态优化充满液体的响应性整形内
Dayna Cracknell1, Mark Battley2, Justin Fernandez2
1Department of Engineering Science, The University of Auckland, Khyber Pass Road, Auckland, 1023, New Zealand. dayna.cracknell@auckland.ac.nz.
Biomechanics and modeling in mechanobiology
|March 3, 2025
概括
这项研究开发了定制的固体液体复合材料 (SLC) 整形内,使用动态数值优化来降低行走过程中峰值的脚部压力. 优化的内显著降低了静态和动态峰值压力,显示出改善足部健康的前景.
科学领域:
- 生物力学 生物力学
- 整形器械和假肢
- 计算建模 计算建模
背景情况:
- 峰值的足底压力有助于足部病理.
- 目前的整形内为压力降低提供有限的定制.
- 动态步态分析对于理解脚与脚之间的相互作用至关重要.
研究的目的:
- 开发一种基于优化的方法来创建定制的固体液体复合材料 (SLC) 整形内.
- 通过动态数值优化来降低步行过程中的峰值脚部压力.
- 通过实验测试来验证优化内的有效性.
主要方法:
- 使用越来越复杂的数值模型开发步态模拟.
- 对数值模型与实验步态分析的验证.
- 使用数字优化为区域压力定制的内设计.
- 原型内的增材制造和实验测试.
主要成果:
- 数字步行模拟显示了与实验数据的良好相关性.
- 优化将静态峰值脚部压力降低了约8%.
- 优化将动态峰值压力的总和减少了50%.
结论:
- 优化的SLC内有效地降低了峰值脚部压力.
- 开发的方法提供了一个可行的替代传统的正内.
- 未来的工作应该改进具有特定主体几何学的数值模型,并进行临床试验.
相关概念视频
Fluid Pressure over Flat Plate of Variable Width
1.2K
When a flat plate is submerged in a fluid, the fluid exerts pressure on the plate. This pressure can lead to many different phenomena, including drag and buoyancy. To understand the behavior of the fluid over a flat plate of variable width, it is essential to analyze the distribution of the pressure exerted.
The pressure distribution on the plate can be calculated by determining the force that acts on a differential area strip of the plate. Thus, the magnitude of the force is equal to the...
The pressure distribution on the plate can be calculated by determining the force that acts on a differential area strip of the plate. Thus, the magnitude of the force is equal to the...
1.2K
Accelerating Fluids
990
When a fluid is in constant acceleration, the pressure and buoyant force equations are modified. Suppose a beaker is placed in an elevator accelerating upward with a constant acceleration, a. In the beaker, assume there is a thin cylinder of height h with an infinitesimal cross-sectional area, ΔS.
The motion of the liquid within this infinitesimal cylinder is considered to obtain the pressure difference. Three vertical forces act on this liquid:
The motion of the liquid within this infinitesimal cylinder is considered to obtain the pressure difference. Three vertical forces act on this liquid:
990
Fluid Pressure over Flat Plate of Constant Width
1.5K
When a body is submerged in water, it experiences fluid pressure acting normal on its surface and distributed over its area. For better design structures, it is crucial to determine the magnitude and location of the resultant force acting on the surface. In the case of a rectangular plate of constant width submerged in water, the pressure increases with depth, resulting in a linearly varying trapezoidal pressure distribution from the upper to the lower edge of the plate.
The resultant force...
The resultant force...
1.5K
Static and Kinetic Frictional Force
15.5K
One of the simpler characteristics of sliding friction is that it is parallel to the contact surfaces between systems, and is always in a direction that opposes the motion or attempted motion of the systems relative to each other. If two systems are in contact and moving relative to one another, then the friction between them is called kinetic friction. For example, kinetic friction slows a hockey puck sliding on ice.
However, if two systems are in contact and are stationary relative to one...
However, if two systems are in contact and are stationary relative to one...
15.5K
Fluid Movement Between Compartments
444
The force applied by fluids against a surface, known as hydrostatic pressure, initiates the transfer of fluid among different compartments. Within our blood vessels, the blood's hydrostatic pressure is a result of the heart's pumping action. At the arteriolar end of capillaries, hydrostatic pressure (capillary blood pressure) exceeds the opposing colloid osmotic pressure created primarily by plasma proteins like albumin. This discrepancy in pressure propels plasma and nutrients from the...
444
Dynamic Modulus of Elasticity of Concrete
249
The dynamic modulus of elasticity assesses how a concrete structure deforms under impact or dynamic loads. It is typically higher than the static modulus of elasticity, measured under slow, steady loading conditions.
The sonic test is a common method to determine the dynamic modulus. In this test, a concrete beam, sized either 6 x 6 x 30 inches or 4 x 4 x 20 inches, is clamped at its center. Vibrations are initiated at one end of the beam by an electromagnetic exciter unit powered by...
The sonic test is a common method to determine the dynamic modulus. In this test, a concrete beam, sized either 6 x 6 x 30 inches or 4 x 4 x 20 inches, is clamped at its center. Vibrations are initiated at one end of the beam by an electromagnetic exciter unit powered by...
249