相关实验视频
Updated: May 24, 2025

08:47
A 3D Cartographic Description of the Cell by Cryo Soft X-ray Tomography
Published on: March 15, 2021
3.8K
软X射线断层扫描已经发展成为揭示细胞结构的强大工具
Venera Weinhardt1,2, Carolyn Larabell2,3,4
1Centre for Organismal Studies, Heidelberg University, Heidelberg, Germany;
概括
软X射线断层扫描 (SXT) 提供高通量,定量3D细胞成像,没有固定. 这种强大的技术揭示了有机体的化学组成和细胞结构,推动了细胞生物学研究.
科学领域:
- 细胞生物学 细胞生物学
- 显微镜的使用方法
- 生物物理学的生物物理.
背景情况:
- 软X射线断层扫描 (SXT) 在过去30年里取得了重大进展.
- 它现在是一种高通量定量成像模式,与光和电子显微镜相提并论.
- SXT解决了细胞生物学中的关键问题.
研究的目的:
- 审查SXT的演变和能力.
- 为了突出SXT在细胞分析方面的独特优势.
- 讨论SXT成像中的当前和未来方向.
主要方法:
- SXT 允许对整个细胞进行无标签,无固定的可视化.
- 它允许对有机体化学组成进行定量分析.
- 分析了细胞的三维结构.
主要成果:
- SXT提供高通量,细胞的定量3D成像.
- 研究人员可以测量器官中的化学变化.
- 数字细胞模型是为运动性研究而创建的.
结论:
- SXT是细胞生物学的一个强大的工具,可以进行定量分析.
- 它的独特能力正在推动新的发现.
- 新兴方向有望进一步融入标准细胞生物学研究.
相关概念视频
Electron Microscope Tomography and Single-particle Reconstruction
2.3K
Transmission electron microscopy (TEM) can be used to determine the 3D structure of biological samples with the help of techniques such as electron microscope tomography and single-particle reconstruction. While single-particle reconstruction can examine macromolecules and macromolecular complexes in vitro conditions only, tomography permits the study of cell components or small cells in vivo.
Electron Tomography
Electron tomography can be performed either in TEM or STEM (scanning transmission...
Electron Tomography
Electron tomography can be performed either in TEM or STEM (scanning transmission...
2.3K
X-ray Diffraction of Biological Samples
3.8K
X-ray diffraction or XRD is an analytical tool that utilizes X-rays to study ordered structures such as crystalline organic and inorganic samples, polycrystalline materials, proteins, carbohydrates, and drugs.
According to Bragg's law, when X-rays strike the sample positioned on a stage, the rays are scattered by the electron clouds around the sample atoms. The X-ray diffraction or scattering is caused by constructive interference of the X-ray waves that reflect off the internal...
According to Bragg's law, when X-rays strike the sample positioned on a stage, the rays are scattered by the electron clouds around the sample atoms. The X-ray diffraction or scattering is caused by constructive interference of the X-ray waves that reflect off the internal...
3.8K
Super-resolution Fluorescence Microscopy
6.8K
Super-resolution fluorescence microscopy (SRFM) provides a better resolution than conventional fluorescence microscopy by reducing the point spread function (PSF). PSF is the light intensity distribution from a point that causes it to appear blurred. Due to PSF, each fluorescing point appears bigger than its actual size, and it is the PSF interference of nearby fluorophores that causes the blurred image. Various approaches to achieving higher resolution through SRFM have recently been...
6.8K
Computed Tomography
4.2K
Tomography refers to imaging by sections. Computed tomography (CT) is a non-invasive imaging technique that uses computers to analyze several cross-sectional X-rays to reveal minute details about structures in the body.
The technique was invented in the 1970s and is based on the principle that as X-rays pass through the body, they are absorbed or reflected at different levels. In the technique, a patient lies on a motorized platform while a computerized axial tomography (CAT) scanner rotates...
The technique was invented in the 1970s and is based on the principle that as X-rays pass through the body, they are absorbed or reflected at different levels. In the technique, a patient lies on a motorized platform while a computerized axial tomography (CAT) scanner rotates...
4.2K
X-ray Imaging
5.3K
German physicist Wilhelm Röntgen (1845–1923) was experimenting with electrical current when he discovered that a mysterious and invisible "ray" would pass through his flesh but leave an outline of his bones on a screen coated with a metal compound. In 1895, Röntgen made the first durable record of the internal parts of a living human: an "X-ray" image (as it came to be called) of his wife’s hand. Scientists worldwide quickly began their own experiments with...
5.3K
Overview of Electron Microscopy
8.5K
The wavelengths of visible light ultimately limit the maximum theoretical resolution of images created by light microscopes. Most light microscopes can only magnify 1000X, and a few can magnify up to 1500X. Electrons, like electromagnetic radiation, can behave like waves, but with wavelengths of 0.005 nm, they produce significantly greater resolution up to 0.05 nm as compared to 500 nm for visible light. An electron microscope (EM) can create a sharp image that is magnified up to 2,000,000X.
8.5K