主动干扰排斥控制与自适应输入增益使用动态反转方法
Radosław Patelski1, Dariusz Pazderski1
1Institute of Automatic Control and Robotics, Poznan University of Technology, ul. Piotrowo 3A, Poznan, 61-138, Poland.
ISA transactions
|March 4, 2025
概括
本研究介绍了对具有未知输入增益的系统的自适应输出反控制,使用主动干扰拒绝控制 (ADRC) 和动态反转来实现稳定的轨迹跟踪.
科学领域:
- 控制系统工程 控制系统工程
- 适应性控制理论 适应性控制理论
- 非线性系统分析 非线性系统分析
背景情况:
- 轨迹跟踪对于许多工业过程至关重要.
- 控制系统中未知的输入收益带来了重大挑战.
- 现有的方法往往在暂时稳定性和参数不确定性方面扎.
研究的目的:
- 开发一种适应性输出反控制策略,用于在未知输入收益的工厂中跟踪轨迹.
- 为了确保在稳定状态条件下无对称的跟踪性能.
- 为了解决暂时不稳定性和参数估计问题.
主要方法:
- 主动干扰拒绝控制 (ADRC) 框架.
- 动态反向用于辅助控制法产生.
- 适应式输入增益识别与平稳和的梯度定律和投影.
主要成果:
- 在无干扰系统中证明了异位追踪和估计误差的趋同.
- 在一般情况下建立的系统轨迹的局限性.
- 在两个实验室测试台上成功进行实验验证.
结论:
- 拟议的自适应控制方法有效地实现了轨迹跟踪,尽管输入收益未知.
- 这种方法确保了瞬态和稳定状态的稳定性.
- 该方法通过实验验证证明了其实际适用性.
更多相关视频
10:51An Experimental Platform to Study the Closed-loop Performance of Brain-machine Interfaces
Published on: March 10, 2011
13.7K
11:44Real-Time DC-dynamic Biasing Method for Switching Time Improvement in Severely Underdamped Fringing-field Electrostatic MEMS Actuators
Published on: August 15, 2014
10.3K
相关概念视频
Inverting and Non-inverting OpAmps
535
In an inverting amplifier, the input voltage is connected through a resistor to the inverting terminal. Meanwhile, the non-inverting terminal is grounded and a feedback resistor is established between the inverting and output terminal, as depicted in Figure 1.
535
Time-Domain Interpretation of PD Control
78
Proportional-Derivative (PD) control is a widely used control method in various engineering systems to enhance stability and performance. In a system with only proportional control, common issues include high maximum overshoot and oscillation, observed in both the error signal and its rate of change. This behavior can be divided into three distinct phases: initial overshoot, subsequent undershoot, and gradual stabilization.
Consider the example of control of motor torque. Initially, a positive...
Consider the example of control of motor torque. Initially, a positive...
78
PD Controller: Design
167
In automotive engineering, car suspension systems often employ Proportional Derivative (PD) controllers to enhance performance. PD controllers are utilized to adjust the damping force in response to road conditions. A controller, acting as an amplifier with a constant gain, demonstrates proportional control, with output directly mirroring input.
Designing a continuous-data controller requires selecting and linking components like adders and integrators, which are fundamental in Proportional,...
Designing a continuous-data controller requires selecting and linking components like adders and integrators, which are fundamental in Proportional,...
167
Control Systems
1.0K
Control systems are everywhere in contemporary society, influencing diverse applications from aerospace to automated manufacturing. These systems can be found naturally within biological processes, such as blood sugar regulation and heart rate adjustment in response to stress, as well as in man-made systems like elevators and automated vehicles. A control system is essentially a network of subsystems and processes that collaboratively convert specific inputs into desired outputs.
At the heart...
At the heart...
1.0K
PI Controller: Design
173
Proportional Integral (PI) controllers are a fundamental component in modern control systems, widely used to enhance performance and mitigate steady-state errors. They are particularly effective in applications such as automatic brightness adjustment on smartphones, where they excel at mitigating steady-state errors for step-function inputs. Unlike PD controllers, which require time-varying errors to function optimally, PI controllers leverage their integral component to address residual...
173
Effects of feedback
501
Feedback in control systems plays a critical role in shaping various operational parameters, extending beyond simple error reduction to influence stability, bandwidth, gain, impedance, and sensitivity. Understanding these effects requires examining a basic feedback system characterized by defined input, output, error, and feedback signals.
Feedback significantly modifies the gain of a control system. The gain of a system without feedback is altered by a factor of one plus GH, where G represents...
Feedback significantly modifies the gain of a control system. The gain of a system without feedback is altered by a factor of one plus GH, where G represents...
501